• IEC 60141-1:1993

    Current The latest, up-to-date edition.

    Tests on oil-filled and gas-pressure cables and their accessories - Part 1: Oil-filled, paper or polypropylene paper laminate insulated, metal-sheathed cables and accessories for alternating voltages up to and including 500 kV

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Language(s): 

    Published date:  06-09-1993

    Publisher:  International Electrotechnical Committee

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    Clause
    SECTION 1: GENERAL
    1.1 Scope
    1.2 Normative references
    1.3 Definitions and symbols
    1.4 Voltage designation
    1.5 Test conditions
    1.6 Characteristics
    1.7 Categories and frequency of tests
    SECTION 2: ROUTINE TESTS ON CABLES
    2.1 General
    2.2 Conductor resistance test
    2.3 Capacitance test
    2.4 Dielectric loss angle test
    2.5 High-voltage test
    2.6 Test on corrosion-resistant coverings
    SECTION 3: SPECIAL TESTS ON CABLES
    3.1 Measurements of thickness
    3.2 Mechanical test
    SECTION 4: TYPE TESTS ON CABLES
    4.1 General
    4.2 Test requirements
    4.3 Dielectric loss angle/temperature test
    4.4 Dielectric security test
    4.5 Lightning impulse voltage test
    SECTION 5: ROUTINE TESTS ON ACCESSORIES
    5.1 General
    5.2 Joint and sealing-end assemblies
    5.3 Pressure tanks - Hydraulic test
    5.4 Pressure gauges
    5.5 Alarm pressure gauges
    SECTION 6: SPECIAL TESTS ON ACCESSORIES
    6.1 Pressure tanks - Pressure/volume test
    SECTION 7: TYPE TESTS ON ACCESSORIES
    7.1 General
    7.2 Test requirement
    7.3 Lightning impulse voltage test
    7.4 Dielectric security test
    SECTION 8: TESTS AFTER INSTALLATION
    8.1 General
    8.2 Oil-flow test
    8.3 Impregnation coefficient
    8.4 High-voltage test
    8.5 Test on corrosion-resistant coverings
    Tables
    1 Dielectric loss angle test requirements
    2 Standard values of system voltages and test
      voltages recommended for cables to be used
      in three-phase systems
    Annex A - Methods of heating cable samples

    Abstract - (Show below) - (Hide below)

    Applies to tests on radial field, oil-filled, paper-insulated, metal-sheathed cables and their accessories, which operate with a minimum static pressure of between 20 kPa (0.2 bar) and 300 kPa (3.0 bar) inclusive, a maximum static pressure of not more than 800 kPa (8.0 bar) and a minimum transient pressure of not less than 20 kPa (0.2 bar). The quoted pressures are above atmospheric pressure. Includes routine, special and type tests on cables and accessories as well as tests after installation. Gives details of methods of heating cable samples.

    General Product Information - (Show below) - (Hide below)

    Development Note Stability Date: 2020. (10/2012)
    Document Type Standard
    Publisher International Electrotechnical Committee
    Status Current
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    BS EN 60695-1-40:2014 Fire hazard testing Guidance for assessing the fire hazard of electrotechnical products. Insulating liquids
    HD 633 S1:1997 Tests on oil-filled (fluid filled), paper- or polypropylene paper laminate-insulated, metal-sheathed cables and accessories for alternating voltages up to and including 400 kV (Um = 420 kV)
    BS EN 62271-203:2012 High-voltage switchgear and controlgear Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV
    BS EN 60517:1997 Gas-insulated metal-enclosed switchgear for rated voltages of 72.5 kV and above
    I.S. EN 62271-209:2007 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 209: CABLE CONNECTIONS FOR GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES ABOVE 52 KV - FLUID-FILLED AND EXTRUDED INSULATION CABLES - FLUID-FILLED AND DRY-TYPE CABLE-TERMINATIONS
    BS EN 62271-209:2007 High-voltage switchgear and controlgear Cable connections for gas-insulated metal-enclosed switchgear for rated voltages above 52 kV. Fluid-filled and extruded insulation cables. Fluid-filled and dry-type cable-terminations
    UNE-EN 62271-203:2013 High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV
    IEC 60695-1-40:2013 Fire hazard testing - Part 1-40: Guidance for assessing the fire hazard of electrotechnical products - Insulating liquids
    EN 62271-209:2007 High-voltage switchgear and controlgear - Part 209: Cable connections for gas-insulated metal-enclosed switchgear for rated voltages above 52 kV - Fluid-filled and extruded insulation cables - Fluid-filled and dry-type cable-terminations
    NF EN 62271-209 : 2008 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 209: CABLE CONNECTIONS FOR GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES ABOVE 52 KV - FLUID-FILLED AND EXTRUDED INSULATION CABLES - FLUID-FILLED AND DRY TYPE CABLE-TERMINATIONS
    BS 6904:1987 Guide for cable connections for gas-insulated metal-enclosed switchgear for rated voltages of 72.5 kV and above
    BIS IS/IEC 62271-203 : 2003 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 203: GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES ABOVE 52 KV
    I.S. EN 50299:2004 OIL-IMMERSED CABLE CONNECTION ASSEMBLIES FOR TRANSFORMERS AND REACTORS HAVING HIGHEST VOLTAGE FOR EQUIPMENT U[M] FROM 72.5 KV TO 550 KV
    CEI EN 62271-209 : 2009 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 209: CABLE CONNECTIONS FOR GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES ABOVE 52 KV - FLUID-FILLED AND EXTRUDED INSULATION CABLES - FLUID-FILLED AND DRY-TYPE CABLE-TERMINATIONS
    08/30179468 DC : DRAFT MAR 2008 BS EN 62271-203 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 203: GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES ABOVE 52 KV
    12/30269145 DC : 0 BS EN 60695-1-40 ED 1.0 - FIRE HAZARD TESTING - PART 1-40: GUIDANCE FOR ASSESSING THE FIRE HAZARD OF ELECTROTECHNICAL PRODUCTS - INSULATING LIQUIDS
    IEC TS 60859:1999 Cable connections for gas-insulated metal-enclosed switchgear for rated voltages of 72,5 kV and above - Fluid-filled and extruded insulation cables - Fluid-filled and dry type cable-terminations
    I.S. EN 60695-1-40:2014 FIRE HAZARD TESTING - PART 1-40: GUIDANCE FOR ASSESSING THE FIRE HAZARD OF ELECTROTECHNICAL PRODUCTS - INSULATING LIQUIDS
    UNE-EN 60695-1-40:2014 Fire hazard testing - Part 1-40: Guidance for assessing the fire hazard of electrotechnical products - Insulating liquids
    IEC TS 60695-1-40:2002 Fire hazard testing - Part 1-40: Guidance for assessing the fire hazard of electrotechnical products - Insulating liquids
    IEC 62271-203:2011 High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV
    IEC 62271-209:2007 High-voltage switchgear and controlgear - Part 209: Cable connections for gas-insulated metal-enclosed switchgear for rated voltages above 52 kV - Fluid-filled and extruded insulation cables - Fluid-filled and dry-type cable-terminations
    IEEE 400.4-2015 IEEE Guide for Field Testing of Shielded Power Cable Systems Rated 5 kV and Above with Damped Alternating Current (DAC) Voltage
    CEI EN 62271-203 : 2013 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 203: GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES ABOVE 52 KV
    CEI EN 60695-1-40 : 2014 FIRE HAZARD TESTING - PART 1-40: GUIDANCE FOR ASSESSING THE FIRE HAZARD OF ELECTROTECHNICAL PRODUCTS - INSULATING LIQUIDS
    I.S. HD 633:1999 TESTS ON OIL-FILLED (FLUID FILLED), PAPER- OR POLYPROPYLENE PAPER LAMINATED-INSULATED, METAL-SHEATHED CABLES AND ACCESSORIES FOR ALTERNATING VOLTAGES UP TO AND INCLUDING 400 KV (UM = 420 KV)
    I.S. EN 62271-203:2012 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 203: GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES ABOVE 52 KV (IEC 62271-203:2011 (EQV))
    EN 62271-203:2012 High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV
    EN 60695-1-40:2014 Fire hazard testing - Part 1-40: Guidance for assessing the fire hazard of electrotechnical products - Insulating liquids

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60228:2004 Conductors of insulated cables
    IEC 60230:1966 Impulse tests on cables and their accessories
    IEC 60183:2015 Guidance for the selection of high-voltage A.C. cable systems
    IEC 60811-1-1:1993+AMD1:2001 CSV Common test methods for insulating and sheathing materials of electric cables and optical cables - Part 1-1: Methods for general application - Measurement of thickness and overall dimensions - Tests for determining the mechanical properties
    IEC 60229:2007 Electric cables - Tests on extruded oversheaths with a special protective function
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective