BS EN 60598-2-22:2014
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Luminaires Particular requirements. Luminaires for emergency lighting
Hardcopy , PDF
27-04-2020
English
30-11-2016
1 Scope
2 Normative references
3 Terms and definitions
4 General test requirements
5 Classification of luminaires
6 Marking
7 Construction
8 Creepage distances and clearances
9 Provision of earthing
10 Terminals
11 External and internal wiring
12 Protection against electric shock
13 Endurance test and thermal test
14 Resistance to dust and moisture
15 Insulation resistance and electric strength
16 Resistance to heat, fire and tracking
17 Photometric data
18 Changeover operation
19 High temperature operation
20 Battery chargers for self-contained emergency luminaires
21 Test devices for emergency operation
Annex A (normative) - Batteries for self-contained emergency luminaires
Annex B (normative) - Luminaire classification
Annex C (normative) - Luminance measurements
Annex D (informative) - Rest mode and inhibition mode facilities
Annex E (normative) - Requirements for self-contained portable
emergency luminaires
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Annex ZB (informative) - A-deviations
Defines requirements for emergency luminaires for use with electrical lamps on emergency power supplies not exceeding 1000 V.
Committee |
CPL/34/4
|
DevelopmentNote |
Supersedes 93/217098 DC. Supersedes 00/242581 DC (07/2003). Supersedes BS 4533-102.22(1990). (04/2006) Included in BIP 3071. (08/2006) Supersedes 05/30140632 DC. (10/2008) 1998 + A2 2008 along with its corrigendum remains current and will be withdrawn on 24/07/2017. Supersedes 11/30249765 DC. (10/2014)
|
DocumentType |
Standard
|
Pages |
36
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
This part of IEC60598 specifies requirements for emergency luminaires for use with electrical lamps on emergency power supplies not exceeding 1000V. This part does not cover the effects of non-emergency voltage reductions on luminaires incorporating high pressure discharge lamps. This part gives general requirements for emergency lighting equipment. This part continues to use the term “lamp” which also includes “light source(s)\' where appropriate.
Standards | Relationship |
EN 60598-2-22:2014/AC:2016-09 | Identical |
SN EN 60598-2-22 : 2014 | Identical |
NF EN 60598-2-22 : 2014 | Identical |
NEN EN 60598-2-22 : 1991 | Identical |
UNE-EN 60598-2-22:2015 | Identical |
IEC 60598-2-22:2014+AMD1:2017 CSV | Identical |
I.S. EN 60598-2-22:2014 | Identical |
DIN EN 60598-2-22 : 2015 COR 2 2017 | Identical |
EN 60598-2-22:2014 | Equivalent |
BS 5266-5:1999 | Emergency lighting Specification for component parts of optical fibre systems |
BS 5266-1:2005 | Emergency lighting Code of practice for the emergency lighting of premises |
BS 5266-1:2016 | Emergency lighting Code of practice for the emergency lighting of premises |
BS 5266-1:1999 | Emergency lighting Code of practice for the emergency lighting of premises other than cinemas and certain other specified premises used for entertainment |
11/30227604 DC : 0 | BS 5266-1 - EMERGENCY LIGHTING - PART 1: CODE OF PRACTICE FOR THE EMERGENCY ESCAPE LIGHTING OF PREMISES |
12/30258581 DC : 0 | BS 5908-2 - FIRE AND EXPLOSION PRECAUTIONS AT PREMISES HANDLING FLAMMABLE GASES, LIQUIDS AND DUSTS - PART 2: GUIDE TO APPLICABLE STANDARDS AND REGULATIONS |
BS 5266-1:2011 | Emergency lighting Code of practice for the emergency escape lighting of premises |
BS 5499-4:2000 | Safety signs, including fire safety signs. Code of practice for escape route signing |
BIP 2081 : 2012 | A GUIDE TO EMERGENCY LIGHTING |
BS 5908-2:2012 | Fire and explosion precautions at premises handling flammable gases, liquids and dusts Guide to applicable standards and regulations |
05/30124836 DC : DRAFT JULY 2005 | BS 5266-1 - EMERGENCY LIGHTING - PART 1: CODE OF PRACTICE FOR THE EMERGENCY LIGHTING OF PREMISES |
13/30260337 DC : 0 | BS 5499-4 - SAFETY SIGNS - PART 4: CODE OF PRACTICE FOR ESCAPE ROUTE SIGNING |
16/30331553 DC : 0 | BS 5266-1 - EMERGENCY LIGHTING - PART 1: CODE OF PRACTICE FOR THE EMERGENCY LIGHTING OF PREMISES |
BS 5266-10:2008 | Guide to the design and provision of emergency lighting to reduce the risks from hazards in the event of failure of the normal lighting supply |
IEC 61347-2-3:2011+AMD1:2016 CSV | Lamp control gear - Part 2-3: Particular requirements for a.c. and/or d.c. supplied electronic control gear for fluorescent lamps |
IEC 62034:2012 | Automatic test systems for battery powered emergency escape lighting |
HD 60364-5-56:2010/A12:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-56: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - SAFETY SERVICES |
IEC 60364-5-56:2009 | Low-voltage electrical installations - Part 5-56: Selection and erection of electrical equipment - Safety services |
2006/95/EC : 2006 | DIRECTIVE 2006/1995/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 12 DECEMBER 2006 ON THE HARMONISATION OF THE LAWS OF MEMBER STATES RELATING TO ELECTRICAL EQUIPMENT DESIGNED FOR USE WITHIN CERTAIN VOLTAGE LIMITS (CODIFIED VERSION) (TEXT WITH EEA RELEVANCE) |
IEC 61347-2-13:2014+AMD1:2016 CSV | Lamp controlgear - Part 2-13: Particular requirements for d.c. ora.c. supplied electronic controlgear for LED modules |
IEC 60073:2002 | Basic and safety principles for man-machine interface, marking and identification - Coding principles for indicators and actuators |
EN 60073:2002 | Basic and safety principles for man-machine interface, marking and identification - Coding principles for indicators and actuators |
EN 61951-1:2017 | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Secondary sealed cells and batteries for portable applications - Part 1: Nickel-cadmium |
IEC 60896-21:2004 | Stationary lead-acid batteries - Part 21: Valve regulated types - Methods of test |
EN 61056-1:2012 | General purpose lead-acid batteries (valve-regulated types) - Part 1: General requirements, functional characteristics - Methods of test |
EN 61347-2-3:2011/A1:2017 | LAMP CONTROL GEAR - PART 2-3: PARTICULAR REQUIREMENTS FOR A.C. AND/OR D.C. SUPPLIED ELECTRONIC CONTROL GEAR FOR FLUORESCENT LAMPS (IEC 61347-2-3:2011/A1:2016) |
EN 61951-2:2017 | Secondary cells and batteries containing alkaline or other non acid electrolytes - Secondary sealed cells and batteries for portable applications - Part 2: Nickel-metal hydride |
IEC 61951-2:2017 | Secondary cells and batteries containing alkaline or other non acid electrolytes - Secondary sealed cells and batteries for portable applications - Part 2: Nickel-metal hydride |
EN 61347-2-7:2012 | Lamp controlgear - Part 2-7: Particular requirements for battery supplied electronic controlgear for emergency lighting (self-contained) |
IEC 61951-1:2017 | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Secondary sealed cells and batteries for portable applications - Part 1: Nickel-Cadmium |
IEC 61347-2-7:2011+AMD1:2017 CSV | Lamp controlgear - Part 2-7: Particular requirements for battery supplied electronic controlgear for emergency lighting (self-contained) |
IEC 61056-1:2012 | General purpose lead-acid batteries (valve-regulated types) - Part 1: General requirements, functional characteristics - Methods of test |
IEC 60598-1:2014+AMD1:2017 CSV | Luminaires - Part 1: General requirements and tests |
IEC 61347-2-12:2005+AMD1:2010 CSV | Lamp controlgear - Part 2-12: Particular requirements for d.c. or a.c. supplied electronic ballasts for discharge lamps (excluding fluorescent lamps) |
IEC 61347-2-2:2011 | Lamp controlgear - Part 2-2: Particular requirements for d.c. or a.c. supplied electronic step-down convertors for filament lamps |
ISO 3864-1:2011 | Graphical symbols Safety colours and safety signs Part 1: Design principles for safety signs and safety markings |
EN 60155:1995/A2:2007 | GLOW-STARTERS FOR FLUORESCENT LAMPS |
IEC 60155:1993 | Glow-starters for fluorescent lamps |
EN 60896-21:2004 | Stationary lead-acid batteries - Part 21: Valve regulated types - Methods of test |
EN 1838:2013 | Lighting applications - Emergency lighting |
EN 62034:2012 | Automatic test systems for battery powered emergency escape lighting |
EN 61347-2-2:2012 | Lamp controlgear - Part 2-2: Particular requirements for d.c. or a.c. supplied electronic step-down convertors for filament lamps |
ISO 3864-4:2011 | Graphical symbols Safety colours and safety signs Part 4: Colorimetric and photometric properties of safety sign materials |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.