BS EN 60603-7-1:2011
Current
The latest, up-to-date edition.
Connectors for electronic equipment Detail specification for 8-way, shielded, free and fixed connectors
Hardcopy , PDF
English
31-07-2011
INTRODUCTION
1 General
2 Terms and definitions
3 Common features and isometric view
4 Cable terminations and internal connections - Fixed and
free connectors
5 Gauges
6 Characteristics
7 Tests and test schedule
Annex A (normative) - Gauging continuity test
Bibliography
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Describes the dimensions, mechanical, electrical and environmental characteristics and tests, in relation to the shield, additional to those in IEC 60603-7.
Committee |
EPL/48
|
DevelopmentNote |
Supersedes 98/232683 DC (08/2002) Supersedes 06/30152213 DC. (01/2010) Supersedes 10/30218335 DC. (07/2011)
|
DocumentType |
Standard
|
Pages |
30
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This part of IEC 60603-7 covers 8-way shielded free and fixed connectors. It specifies the dimensions, mechanical, electrical and environmental characteristics and tests, in relation to the shield, additional to those in IEC 60603-7.
These connectors are intermateable and interoperable with other IEC 60603-7 series connectors as defined in IEC 60603-7.
Standards | Relationship |
DIN EN 60603-7-1 : 2012 | Identical |
EN 60603-7-1:2011 | Identical |
IEC 60603-7-1:2011 | Identical |
I.S. EN 60603-7-1:2011 | Identical |
DEFSTAN 21-88(PT4)/4(2012) : 2012 | POLICIES AND PROCEDURES FOR SYSTEM INTEGRATION IN SURFACE SHIPS - PART 4: LEGACY PLATFORM DEDICATED INTERFACES |
DEFSTAN 21-88/2(2006) : 2006 | POLICIES AND PROCEDURES FOR COMBAT SYSTEM INTEGRATION IN SURFACE SHIPS (SSP 88) |
IEC 60603-7-71:2010 | Connectors for electronic equipment - Part 7-71: Detail specification for 8-way, shielded, free and fixed connectors, for data transmission with frequencies up to 1 000 MHz |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
IEC 62153-4-12:2009 | Metallic communication cable test methods - Part 4-12: Electromagnetic compatibility (EMC) - Coupling attenuation or screening attenuation of connecting hardware - Absorbing clamp method |
EN 60512-1-100:2012 | Connectors for electronic equipment - Tests and measurements - Part 1-100: General - Applicable publications |
EN ISO 1302:2002 | Geometrical Product Specifications (GPS) - Indication of surface texture in technical product documentation (ISO 1302:2002) |
ISO/IEC 11801:2002 | Information technology Generic cabling for customer premises |
EN 60512-1:2001 | Connectors for electronic equipment - Tests and measurements - Part 1: General |
IEC 60068-2-38:2009 | Environmental testing - Part 2-38: Tests - Test Z/AD: Composite temperature/humidity cyclic test |
ISO 1302:2002 | Geometrical Product Specifications (GPS) Indication of surface texture in technical product documentation |
EN 60068-2-38:2009 | Environmental testing - Part 2-38: Tests - Test Z/AD: Composite temperature/humidity cyclic test |
IEC 60603-7:2008+AMD1:2011 CSV | Connectors for electronic equipment - Part 7: Detail specification for 8-way, unshielded, free and fixed connectors |
IEC 60512-1-100:2012 | Connectors for electronic equipment - Tests and measurements - Part 1-100: General - Applicable publications |
EN 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
EN 60603-7:2009/A1:2011 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7: DETAIL SPECIFICATION FOR 8-WAY, UNSHIELDED, FREE AND FIXED CONNECTORS (IEC 60603-7:2008/A1:2011) |
IEC 61156-5:2009+AMD1:2012 CSV | Multicore and symmetrical pair/quad cables for digital communications - Part 5: Symmetrical pair/quad cables withtransmission characteristics up to 1 000 MHz - Horizontal floorwiring - Sectional specification |
IEC 60512-1:2001 | Connectors for electronic equipment - Tests and measurements - Part 1: General |
IEC 60603-7-7:2010 | Connectors for electronic equipment - Part 7-7: Detail specification for 8-way, shielded, free and fixed connectors for data transmission with frequencies up to 600 MHz |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.