BS EN 60603-7-7:2010
Current
The latest, up-to-date edition.
Connectors for electronic equipment Detail specification for 8-way, shielded, free and fixed connectors for data transmission with frequencies up to 600 MHz
Hardcopy , PDF
English
31-10-2010
FOREWORD
INTRODUCTION
1 General
2 Terms and definitions
3 Common features and isometric view
4 Cable terminations and internal connections
5 Gauges
6 Characteristics
7 Tests and test schedule
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Specifies 8-way, shielded, free and fixed connectors, references dimensional, mechanical, electrical and environmental characteristics and tests in IEC 60603-7 and IEC 60603-7-1, and specifies electrical transmission requirements for frequencies up to 600 MHz.
Committee |
EPL/48
|
DevelopmentNote |
Supersedes 00/201586 DC (08/2002) Supersedes 03/100336 DC (08/2006) Supersedes 09/30201591 DC. (11/2010)
|
DocumentType |
Standard
|
Pages |
34
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
IEC 60603-7-7:2010 covers 8-way, shielded, free and fixed connectors, references dimensional, mechanical, electrical and environmental characteristics and tests in IEC 60603-7 and IEC 60603-7-1, and specifies electrical transmission requirements for frequencies up to 600 MHz. These connectors are typically used as category 7 connectors in class F cabling systems specified in ISO/IEC 11801. These connectors are intermateable and interoperable with other IEC 60603-7 series connectors as defined in Clause 2 of IEC 60603-7-1. This third edition of IEC 60603-7-7 cancels and replaces the second edition issued in 2006, and constitutes a technical revision. The main technical changes are as follows:
- Removal of test methods that are now referenced to IEC 60512-26-100;
- addition of TCL and TCTL requirements and removal of the electrical, mechanical, dimensional, environmental conditioning tests by reference to IEC 60603-7.
Standards | Relationship |
NF EN 60603-7-7 : 2012 | Identical |
I.S. EN 60603-7-7:2010 | Identical |
SN EN 60603-7-7 : 2006 | Identical |
IEC 60603-7-7:2010 | Identical |
DIN EN 60603-7-7 : 2011 | Identical |
EN 60603-7-7:2010 | Identical |
DEFSTAN 21-88(PT4)/4(2012) : 2012 | POLICIES AND PROCEDURES FOR SYSTEM INTEGRATION IN SURFACE SHIPS - PART 4: LEGACY PLATFORM DEDICATED INTERFACES |
DEFSTAN 21-88/2(2006) : 2006 | POLICIES AND PROCEDURES FOR COMBAT SYSTEM INTEGRATION IN SURFACE SHIPS (SSP 88) |
IEC 60603-7-1:2011 | Connectors for electronic equipment - Part 7-1: Detail specification for 8-way, shielded, free and fixed connectors |
EN 60512-25-9 : 2008 | CONNECTORS FOR ELECTRONIC EQUIPMENT - TESTS AND MEASUREMENTS - PART 25-9: SIGNAL INTEGRITY TESTS - TEST 25I: ALIEN CROSSTALK |
IEC 60603-7-71:2010 | Connectors for electronic equipment - Part 7-71: Detail specification for 8-way, shielded, free and fixed connectors, for data transmission with frequencies up to 1 000 MHz |
IEC 62153-4-12:2009 | Metallic communication cable test methods - Part 4-12: Electromagnetic compatibility (EMC) - Coupling attenuation or screening attenuation of connecting hardware - Absorbing clamp method |
EN 60512-1-100:2012 | Connectors for electronic equipment - Tests and measurements - Part 1-100: General - Applicable publications |
ISO/IEC 11801:2002 | Information technology Generic cabling for customer premises |
IEC 60512-27-100:2011 | Connectors for electronic equipment - Tests and measurements - Part 27-100: Signal integrity tests up to 500 MHz on 60603-7 series connectors - Tests 27a to 27g |
IEC 60512-26-100:2008+AMD1:2011 CSV | Connectors for electronic equipment - Tests and measurements - Part 26-100: Measurement setup, test and reference arrangements and measurements for connectors according to IEC 60603-7 - Tests 26a to 26g |
EN 60603-7-71 : 2010 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7-71: DETAIL SPECIFICATION FOR 8-WAY, SHIELDED, FREE AND FIXED CONNECTORS, FOR DATA TRANSMISSION WITH FREQUENCIES UP TO 1000 MHZ |
IEC 60603-7:2008+AMD1:2011 CSV | Connectors for electronic equipment - Part 7: Detail specification for 8-way, unshielded, free and fixed connectors |
IEC 60512-1-100:2012 | Connectors for electronic equipment - Tests and measurements - Part 1-100: General - Applicable publications |
IEC 60512-2-1:2002 | Connectors for electronic equipment - Tests and measurements - Part 2-1: Electrical continuity and contact resistance tests - Test 2a: Contact resistance - Millivolt level method |
EN 60512-27-100:2012 | Connectors for electronic equipment - Tests and measurements - Part 27-100: Signal integrity tests up to 500 MHz on IEC 60603-7 series connectors - Tests 27a to 27g |
EN 60603-7:2009/A1:2011 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7: DETAIL SPECIFICATION FOR 8-WAY, UNSHIELDED, FREE AND FIXED CONNECTORS (IEC 60603-7:2008/A1:2011) |
EN 60603-7-1:2011 | Connectors for electronic equipment - Part 7-1: Detail specification for 8-way, shielded, free and fixed connectors |
IEC 60512-25-9:2008 | Connectors for electronic equipment - Tests and measurements - Part 25-9: Signal integrity tests - Test 25i: Alien crosstalk |
IEC 60603-7-51:2010 | Connectors for electronic equipment - Part 7-51: Detail specification for 8-way, shielded, free and fixed connectors, for data transmissions with frequencies up to 500 MHz |
EN 60512-2-1:2002 | Connectors for electronic equipment - Tests and measurements - Part 2-1: Electrical continuity and contact resistance tests - Test 2a: Contact resistance - Millivolt level method |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.