BS EN 60770-2:2010
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
Transmitters for use in industrial-process control systems Methods for inspection and routine testing
Hardcopy , PDF
English
31-03-2011
20-05-2021
Foreword
INTRODUCTION
1 Scope and object
2 Normative references
3 Terms and definitions
4 Sampling for test
5 Performance tests
6 Test report and documentation
Bibliography
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Pertains to transmitters, which have either a standard analogue electric current output signal or a standard pneumatic output analogue signal in accordance with IEC 60381-1 or IEC 60382.
| Committee |
GEL/65/2
|
| DevelopmentNote |
Supersedes 99/243401 DC (06/2003) Supersedes 08/30176950 DC. (03/2011)
|
| DocumentType |
Standard
|
| Pages |
20
|
| PublisherName |
British Standards Institution
|
| Status |
Withdrawn
|
| SupersededBy | |
| Supersedes |
This part of IEC 60770 is applicable to transmitters, which have either a standard analogue electric current output signal or a standard pneumatic output analogue signal in accordance with IEC 60381-1 or IEC 60382. The tests detailed herein may be applied to transmitters which have other output signals, provided that due allowance is made for such differences.
For the method of inspection and routine testing of the intelligent transmitters see IEC 60770-3.
For certain types of transmitters, where the sensor is an integral part, other specific IEC or ISO standards may need to be consulted (e.g. for chemical analyzers, flow-meters, etc.)
This standard is intended to provide technical methods for inspection and routine testing of transmitters, for instance, for acceptance tests or after repair. For a full evaluation, IEC 60770-1 and/or IEC 60770-3, respectively for analogue or intelligent transmitters shall be used.
Quantitative criteria for acceptable performance should be established by agreement between manufacturer and user.
By agreement the tests need not be carried out by an accredited laboratory.
| Standards | Relationship |
| DIN EN 60770-2 : 2011 | Identical |
| NF EN 60770-2 : 2011 | Identical |
| I.S. EN 60770-2:2010 | Identical |
| EN 60770-2:2010 | Identical |
| NBN EN 60770-2 : 2011 | Identical |
| IEC 60770-2:2010 | Identical |
| UNE-EN 60770-2:2010 | Equivalent |
A newer version of this standard is available.