BS EN 60896-22:2004
Current
The latest, up-to-date edition.
Stationary lead-acid batteries Valve regulated types. Requirements
Hardcopy , PDF
English
30-11-2009
1 Scope
2 Normative references
3 Terms and definitions
4 Functional requirements
5 Reporting format
6 Requirements and characteristics
Annex A (normative) - User statement of requirements
Annex B (normative) - Supplier statement of product range
test results
Annex ZA (normative) - Normative references to international
publications with their corresponding
European publications
Bibliography
Pertains to all stationary lead-acid cells and monobloc batteries of the valve regulated type for float charge applications, (i.e. permanently connected to a load and to a d.c. power supply), in a static location (i.e. not generally intended to be moved from place to place) and incorporated into stationary equipment or installed in battery rooms for use in telecom, uninterruptible power supply (UPS), utility switching, emergency power or similar applications.
Committee |
PEL/21
|
DevelopmentNote |
Together with BS EN 60896-21, it supersedes BS 6290-4(1997). (09/2009)
|
DocumentType |
Standard
|
Pages |
32
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This part of IEC 60896 applies to all stationary lead-acid cells and monobloc batteries of the valve regulated type for float charge applications, (i.e. permanently connected to a load and to a d.c. power supply), in a static location (i.e. not generally intended to be moved from place to place) and incorporated into stationary equipment or installed in battery rooms for use in telecom, uninterruptible power supply (UPS), utility switching, emergency power or similar applications.
The objective of this part of IEC 60896 is to assist the specifier in the understanding of the purpose of each test contained within IEC 60896-21 and provide guidance on a suitable requirement that will result in the battery meeting the needs of a particular industry application and operational condition. This standard is used in conjunction with the common test methods described in IEC 60896-21 and is associated with all types and construction of valve regulated stationary lead-acid cells and monoblocs used in standby power applications.
This part of IEC 60896 does not apply to lead-acid cells and batteries used for vehicle engine starting applications (IEC 60095 series), solar photovoltaic applications (IEC 61427), or general purpose applications (IEC 61056 series).
Standards | Relationship |
I.S. EN 60896-22:2004 | Identical |
EN 60896-22:2004 | Identical |
DIN EN 60896-22:2004-12 | Identical |
UNE-EN 60896-22:2004 | Identical |
NF EN 60896-22 : 2004 | Identical |
IEC 60896-22:2004 | Identical |
NBN EN 60896-22 : 2005 | Identical |
BIP 2081 : 2012 | A GUIDE TO EMERGENCY LIGHTING |
IEC 60950-1:2005+AMD1:2009+AMD2:2013 CSV | Information technology equipment - Safety - Part 1: General requirements |
IEC 61427:2005 | Secondary cells and batteries for photovoltaic energy systems (PVES) - General requirements and methods of test |
IEC 60050-151:2001 | International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices |
IEC 60896-21:2004 | Stationary lead-acid batteries - Part 21: Valve regulated types - Methods of test |
IEC 60050-486:1991 | International Electrotechnical Vocabulary (IEV) - Part 486: Secondary cells and batteries |
IEC 60707:1999 | Flammability of solid non-metallic materials when exposed to flame sources - List of test methods |
IEC 60050-603:1986 | International Electrotechnical Vocabulary (IEV) - Part 603: Generation, transmission and distribution of electricity - Power systems planning and management |
IEC 60695-11-10:2013 | Fire hazard testing - Part 11-10: Test flames - 50 W horizontal and vertical flame test methods |
ISO 9001:2015 | Quality management systems — Requirements |
ISO 9000:2015 | Quality management systems — Fundamentals and vocabulary |
IEC 60359:2001 | Electrical and electronic measurement equipment - Expression of performance |
IEC 60050-826:2004 | International Electrotechnical Vocabulary (IEV) - Part 826: Electrical installations |
ISO 1043-1:2011 | Plastics — Symbols and abbreviated terms — Part 1: Basic polymers and their special characteristics |
EN 60896-21:2004 | Stationary lead-acid batteries - Part 21: Valve regulated types - Methods of test |
IEC 60050-300:2001 | International Electrotechnical Vocabulary (IEV) - Part 300: Electrical and electronic measurements and measuring instruments - Part 311: General terms relating to measurements - Part 312: General terms relating to electrical measurements - Part 313: Types of electrical measuring instruments - Part 314: Specific terms according to the type of instrument |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.