BS EN 60947-6-1:2005
Current
The latest, up-to-date edition.
Low-voltage switchgear and controlgear Multiple function equipment. Transfer switching equipment
Hardcopy , PDF
English
01-02-2006
1 Scope and object
2 Normative references
3 Terms and definitions, symbols and abbreviations
4 Classification
5 Characteristics
6 Product information
7 Normal service, mounting and transport conditions
8 Constructional and performance requirements
9 Tests
Annex A (normative) - Assignment of utilization categories
based on the results of tests
Annex B (informative) - Items subject to agreement between
manufacturer and user
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Annex ZZ (informative) - Coverage of Essential Requirements
of EU Directives
Bibliography
Pertains to transfer switching equipment (TSE) to be used in power systems for transferring a load supply between a normal and an alternate source with a supply interruption during transfer, the rated voltage of which does not exceed 1000 V a.c. or 1500 V d.c.
Committee |
PEL/17/2
|
DevelopmentNote |
Supersedes 84/29897 DC & 91/34060 DC. (12/2005) Supersedes 02/207961 DC. (03/2006) 2005 Edition Re-Issued in July 2014 & incorporates AMD 1 2014. Supersedes 11/30257130 DC. (08/2014)
|
DocumentType |
Standard
|
Pages |
50
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This part of IEC 60947applies to transfer switching equipment (TSE) to be used in power systems with interruption of the supply to the load during transfer, the rated voltage of which does not exceed 1 000 V a.c. or 1 500 V d.c.
Standards | Relationship |
EN 60947-6-1:2005/A1:2014 | Identical |
SN EN 60947-6-1 : 1993 AMD 2 1997 | Identical |
IEC 60947-6-1:2005+AMD1:2013 CSV | Identical |
DIN EN 60947-6-1 : 2014 | Identical |
UNE-EN 60947-6-1:2006 | Identical |
I.S. EN 60947-6-1:2005 | Identical |
13/30264663 DC : 0 | BS 7346-7 - COMPONENTS FOR SMOKE AND HEAT CONTROL SYSTEMS - PART 7: CODE OF PRACTICE ON FUNCTIONAL RECOMMENDATIONS AND CALCULATION METHODS FOR SMOKE AND HEAT CONTROL SYSTEMS FOR COVERED CAR PARKS |
BS 7671(2008) : 2018 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
BS 7346-7:2013 | Components for smoke and heat control systems Code of practice on functional recommendations and calculation methods for smoke and heat control systems for covered car parks |
ASHRAE 90.4 : 2016 | ENERGY STANDARD FOR DATA CENTERS |
BS 7671(2008) : 2008 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
IEC 60947-6-2:2002+AMD1:2007 CSV | Low-voltage switchgear and controlgear - Part 6-2: Multiple function equipment - Control and protective switching devices (or equipment) (CPS) |
IEC 60364-5-56:2009 | Low-voltage electrical installations - Part 5-56: Selection and erection of electrical equipment - Safety services |
EN 60947-4-3:2014 | Low-voltage switchgear and controlgear - Part 4-3: Contactors and motor-starters - AC semiconductor controllers and contactors for non-motor loads |
IEC 60947-4-1:2009+AMD1:2012 CSV | Low-voltage switchgear and controlgear - Part 4-1: Contactors and motor-starters - Electromechanical contactors and motor-starters |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
EN 61000-4-2:2009 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
EN 60947-1:2007/A2:2014 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: GENERAL RULES (IEC 60947-1:2007/A2:2014) |
IEC 60364-1:2005 | Low-voltage electrical installations - Part 1: Fundamental principles, assessment of general characteristics, definitions |
IEC 61000-4-6:2013 | Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
EN 60947-3:2009/A2:2015 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 3: SWITCHES, DISCONNECTORS, SWITCH-DISCONNECTORS AND FUSE-COMBINATION UNITS (IEC 60947-3:2008/A2:2015) |
EN 60947-4-1 : 2010 AMD 1 2012 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 4-1: CONTACTORS AND MOTOR-STARTERS - ELECTROMECHANICAL CONTACTORS AND MOTOR-STARTERS (IEC 60947-4-1:2009/A1:2012) |
IEC 60947-1:2007+AMD1:2010+AMD2:2014 CSV | Low-voltage switchgear and controlgear - Part 1: General rules |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 60695-11-10:2013 | Fire hazard testing - Part 11-10: Test flames - 50 W horizontal and vertical flame test methods |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
IEC 60947-4-2:2011 | Low-voltage switchgear and controlgear - Part 4-2: Contactors and motor-starters - AC semiconductor motor controllers and starters |
EN 61000-4-4:2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012) |
CISPR 11:2015 RLV | Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |
IEC 60947-3:2008+AMD1:2012+AMD2:2015 CSV | Low-voltage switchgear and controlgear - Part 3: Switches, disconnectors, switch-disconnectors and fuse-combination units |
EN 61000-4-6:2014/AC:2015 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013) |
IEC 60947-2:2016 | Low-voltage switchgear and controlgear - Part 2: Circuit-breakers |
EN 60947-2:2017 | Low-voltage switchgear and controlgear - Part 2: Circuit-breakers |
IEC 60947-4-3:2014 | Low-voltage switchgear and controlgear - Part 4-3: Contactors and motor-starters - AC semiconductor controllers and contactors for non-motor loads |
EN 60947-4-2:2012 | Low-voltage switchgear and controlgear - Part 4-2: Contactors and motor-starters - AC semiconductor motor controllers and starters |
EN 61000-4-13:2002/A2:2016 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-13: TESTING AND MEASUREMENT TECHNIQUES - HARMONICS AND INTERHARMONICS INCLUDING MAINS SIGNALLING AT A.C. POWER PORT, LOW FREQUENCY IMMUNITY TESTS (IEC 61000-4-13:2002/A2:2015) |
IEC 61000-4-13:2002+AMD1:2009+AMD2:2015 CSV | Electromagnetic compatibility (EMC) - Part 4-13: Testing and measurement techniques - Harmonics and interharmonics includingmains signalling at a.c. power port, low frequency immunity tests |
EN 60947-6-2:2003/A1:2007 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 6-2: MULTIPLE FUNCTION EQUIPMENT - CONTROL AND PROTECTIVE SWITCHING DEVICES (OR EQUIPMENT) (CPS) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-