BS EN 61094-8:2012
Current
The latest, up-to-date edition.
Electroacoustics. Measurement microphones Methods for determining the free-field sensitivity of working standard microphones by comparison
Hardcopy , PDF
English
31-05-2013
1 Scope
2 Normative references
3 Terms and definitions
4 Reference environmental conditions
5 Principles of free-field calibration by comparison
6 General requirements
7 Factors influencing the free-field sensitivity
8 Calibration uncertainty components
Annex A (informative) - Basic substitution calibration in
a free-field chamber
Annex B (informative) - Time selective techniques
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Bibliography
Pertains to working standard microphones meeting the requirements of IEC 61094-4.
Committee |
EPL/29
|
DevelopmentNote |
Supersedes 11/30255884 DC. (12/2012)
|
DocumentType |
Standard
|
Pages |
34
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This part of the IEC61094 series is applicable to working standard microphones meeting the requirements of IEC61094-4. It describes methods of determining the free-field sensitivity by comparison with a laboratory standard microphone or working standard microphone (where applicable) that has been calibrated according to either:
IEC61094-3,
IEC61094-2 or IEC61094-5, and where factors given in IEC/TS61094-7 have been applied,
IEC61094-6,
this part of IEC61094.
Methods performed in an acoustical environment that is a good approximation to an ideal free-field (e.g. a high quality free-field chamber), and methods that use post processing of results to minimise the effect of imperfections in the acoustical environment, to simulate free-field conditions, are both covered by this part of IEC61094. Comparison methods based on the principles described in IEC61094-3 are also possible but beyond the scope of this part of IEC61094.
NOTE 1 This part of IEC61094 is also applicable to laboratory standard microphones meeting the requirements of IEC61094-1, noting that these microphones also meet the electroacoustic specifications for working standard microphones.
NOTE 2 This part of IEC61094 is also applicable to combinations of microphone and preamplifier where the determined sensitivity is referred to the unloaded output voltage of the preamplifier.
NOTE 3 Other devices, for example, sound level meters can be calibrated using the principles of this part of IEC61094, but are not within the scope of this standard.
Standards | Relationship |
EN 61094-8:2012/AC:2013 | Identical |
IEC 61094-8:2012 | Identical |
EN 61094-8:2012 | Equivalent |
IEC 61094-5:2016 | Electroacoustics - Measurement microphones - Part 5: Methods for pressure calibration of working standard microphones by comparison |
EN 61094-5:2016 | Electroacoustics - Measurement microphones - Part 5: Methods for pressure calibration of working standard microphones by comparison |
EN 61094-4:1995 | Measurement microphones - Part 4: Specifications for working standard microphones |
IEC TS 61094-7:2006 | Measurement microphones - Part 7: Values for the difference between free-field and pressure sensitivity levels of laboratory standard microphones |
IEC 61094-4:1995 | Measurement microphones - Part 4: Specifications for working standard microphones |
ISO 26101:2017 | Acoustics Test methods for the qualification of free-field environments |
EN 61094-1:2000 | Measurement microphones - Part 1: Specifications for laboratory standard microphones |
IEC 61094-1:2000 | Measurement microphones - Part 1: Specifications for laboratory standard microphones |
EN 61094-2:2009 | Electroacoustics - Measurement microphones - Part 2: Primary method for pressure calibration of laboratory standard microphones by the reciprocity technique |
EN 61094-6:2005 | Measurement microphones - Part 6: Electrostatic actuators for determination of frequency response |
IEC 61094-3:2016 | Electroacoustics - Measurement microphones - Part 3: Primary method for free-field calibration of laboratory standard microphones by the reciprocity technique |
ISO 18233:2006 | Acoustics Application of new measurement methods in building and room acoustics |
IEC 61094-2:2009 | Electroacoustics - Measurement microphones - Part 2: Primary method for pressure calibration of laboratory standard microphones by the reciprocity technique |
IEC 61094-6:2004 | Measurement microphones - Part 6: Electrostatic actuators for determination of frequency response |
EN 61094-3:2016/AC:2017-01 | ELECTROACOUSTICS - MEASUREMENT MICROPHONES - PART 3: PRIMARY METHOD FOR FREE-FIELD CALIBRATION OF LABORATORY STANDARD MICROPHONES BY THE RECIPROCITY TECHNIQUE |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.