BS EN 61195:2000
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Double-capped fluorescent lamps. Safety specifications
Hardcopy
22-05-2024
English
15-04-2000
1 General
2 Safety requirements
3 Assessment
Annex A (normative) - Test holder for torsion test for
G5 and G13 capped lamps
Annex B (normative) - Test for lamp cap temperature rise
Annex C (informative) - Information for luminaire design
Annex D (normative) Conditions of compliance for
design tests
Annex E (informative) - Information for ballast design
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Bibliography
Describes the safety requirements for double-capped fluorescent lamps for general lighting purposes of all groups having Fa6, Fa8, G5, G13, 2G13, R17d and W4.3x8.5d caps.
Committee |
CPL/34/1
|
DevelopmentNote |
Supersedes 98/200706 DC. (04/2003) Supersedes 11/30257881 DC. (06/2013) 1999 Edition Re-Issued in January 2015 & incorporates AMD 2 2015. Supersedes 13/30287020 DC. (02/2015)
|
DocumentType |
Standard
|
Pages |
28
|
PublisherName |
British Standards Institution
|
Status |
Withdrawn
|
Supersedes |
Specifies the safety requirements for double-capped fluorescent lamps for general lighting purposes of all groups having Fa6, Fa8, G5, G13 and R17d caps. Also specifies the method a manufacturer should use to show compliance with the requirements of this standard. The contents of the corrigendum of August 2000 have been included in this copy.
Standards | Relationship |
NF EN 61195 : 2001 AMD 2 2015 | Identical |
SN EN 61195 : 1999 | Identical |
DIN EN 61195 : 2015 | Identical |
IEC 61195:1999+AMD1:2012+AMD2:2014 CSV | Identical |
EN 61195:1999/A2:2015 | Identical |
NBN EN 61195 : 2000 AMD 2 2015 | Identical |
UNE-EN 61195:2001 | Identical |
I.S. EN 61195:2003 | Identical |
BS 1853-2:1995 | Tubular fluorescent lamps for general lighting service Specification for lamps used in the United Kingdom not included in BS EN 60081, BS EN 60901, BS EN 61195 and BS EN 61199 |
IEC 60061-3:2005 CSV | Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 3: Gauges |
IEC TR 62471-2:2009 | Photobiological safety of lamps and lamp systems - Part 2: Guidance on manufacturing requirements relating to non-laser optical radiation safety |
IEC 60061-2:2005 CSV | Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 2: Lampholders |
IEC 60695-2-10:2000 | FIRE HAZARD TESTING - TEST METHODS - GLOW-WIRE TEST METHODS - GENERAL |
IEC 60410:1973 | Sampling plans and procedures for inspection by attributes |
EN 60921:2004/A1:2006 | BALLASTS FOR TUBULAR FLUORESCENT LAMPS - PERFORMANCE REQUIREMENTS |
IEC 60921:2004+AMD1:2006 CSV | Ballasts for tubular fluorescent lamps - Performance requirements |
EN 60695-2-1-0 : 1996 | FIRE HAZARD TESTING - TEST METHODS - GLOW-WIRE TEST METHODS - GENERAL |
IEC 60598-1:2014+AMD1:2017 CSV | Luminaires - Part 1: General requirements and tests |
IEC 60061-1:2005 CSV | Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 1: Lamp caps |
IEC 62471:2006 | Photobiological safety of lamps and lamp systems |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.