BS EN 61207-6:2015
Current
The latest, up-to-date edition.
Expression of performance of gas analyzers Photometric analyzers
Hardcopy , PDF
English
31-01-2015
INTRODUCTION
1 Scope and object
2 Normative references
3 Terms and definitions
4 Procedure for specification
5 Recommended standard values and range
of influence quantities
6 Procedures for compliance testing
Annex A (normative) - Techniques and systems of
photometric analysis
Annex B (informative) - Methods of preparation of
water-vapor in test gases
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Pertains to all aspects of analyzers using photometric techniques for the measurement of concentration of one or more components in a mixture of gases or vapors.
Committee |
GEL/65/2
|
DevelopmentNote |
Supersedes 90/23869 DC (11/2005) 1994 Edition remains active & will be withdrawn on 30/12/2017. (02/2015)
|
DocumentType |
Standard
|
Pages |
26
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This part of IEC61207 applies to all aspects of analyzers using photometric techniques for the measurement of concentration of one or more components in a mixture of gases or vapors. It should be used in conjunction with IEC61207‑1 . For photometric analyzers utilizing tuneable semiconductor laser absorption spectroscopy (TSLAS) for gas measurements, IEC61207‑7 should also be referred to. This part of IEC61207 applies to analyzers using non-dispersive and dispersive wavelength selection and using absorption, emission, wavelength derivative or scattering techniques. It applies to analyzers which receive either a conditioned or unconditioned sample of gas either under vacuum, at ambient pressure or pressurized. It applies to analyzers which measure gas concentrations directly within the sample gas. The object of this part is: to specify the terminology and definitions related to the functional performance of gas analyzers, utilizing a photometric analyzer, for the continuous measurement of gas or vapor concentration in a source gas; to unify methods used in making and verifying statements on the functional performance of such analyzers; to specify what tests should be performed to determine the functional performance and how such tests should be carried out; to provide basic documents to support the application of standards of quality assurance ISO9001 .
Standards | Relationship |
IEC 61207-6:2014 | Identical |
I.S. EN 61207-6:2015 | Identical |
DIN EN 61207-6:2016-03 | Identical |
EN 61207-6:2015 | Identical |
NF EN 61207-6 : 2015 | Identical |
NBN EN 61207-6 : 2015 | Identical |
UNE-EN 61207-6:2004 | Identical |
SN EN 61207-6:2015 | Identical |
EN 60079-29-4:2010 | Explosive atmospheres - Part 29-4: Gas detectors - Performance requirements of open path detectors for flammable gases |
EN 60079-29-1:2016 | Explosive atmospheres - Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases |
EN 61207-1:2010 | Expression of performance of gas analyzers - Part 1: General |
IEC 60079-29-4:2009 | Explosive atmospheres - Part 29-4: Gas detectors - Performance requirements of open path detectors for flammable gases |
EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
ISO 9001:2015 | Quality management systems — Requirements |
EN 61207-7:2013/AC:2015 | EXPRESSION OF PERFORMANCE OF GAS ANALYZERS - PART 7: TUNEABLE SEMICONDUCTOR LASER GAS ANALYZERS (IEC 61207-7:2013) |
IEC 61207-1:2010 | Expression of performance of gas analyzers - Part 1: General |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.