BS EN 61378-2:2001

Current

Current

The latest, up-to-date edition.

Convertor transformers Transformers for HVDC applications

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

15-08-2001

€231.38
Excluding VAT

1 General
   1.1 Scope
   1.2 Service conditions
2 Normative references
3 Definitions
4 List of variables
5 Ratings
   5.1 General
   5.2 Rated voltage
   5.3 Rated current
   5.4 Rated frequency
   5.5 Rated power
6 Tolerances
   6.1 General
   6.2 Short-circuit impedance tolerances
   6.3 Guarantees
7 Losses
   7.1 General
   7.2 No-load loss
   7.3 Load loss under rated power-frequency
       conditions
   7.4 Load loss under service conditions
   7.5 Determination of hot-spot temperature
8 Insulation levels
   8.1 Line windings
   8.2 Valve windings
   8.3 Induced voltage level with partial discharge
       measurements
9 Sound level
   9.1 General
   9.2 Guaranteed sound-power levels
   9.3 Sound-power level at site
10 Testing
   10.1 General
   10.2 Tests
   10.3 Load-loss measurements
   10.4 Factory dielectric tests
   10.5 Temperature-rise test
   10.6 Load-current test
   10.7 Determination of transformer sound-power
        level
11 High-frequency modelling
12 Loading of transformer above rating
13 Bushings
   13.1 AC bushings
   13.2 Valve winding bushings
14 Tap-changer
   14.1 General
   14.2 Current wave shape
Bibliography
Table 1 - Test conditions for three-winding
          transformers
Annex ZA (normative) Normative references to
                     international publications
                     with their corresponding
                     European publications

Applicable to oil-immersed three-phase and single-phase convertor transformers for use in HVDC power transmission.

Committee
PEL/14
DevelopmentNote
Also numbered as IEC 61378-2 (06/2001) Supersedes 00/203496 DC (10/2004)
DocumentType
Standard
Pages
28
PublisherName
British Standards Institution
Status
Current
Supersedes

This part of IEC 61378 applies to oil-immersed three-phase and -single-phase convertor transformers for use in HVDC power transmission. It applies to transformers having two, three or multiple windings. This standard does not apply to convertor transformers for industrial applications (see IEC 61378-1) and to convertor transformers for traction applications (see IEC 60310).

Standards Relationship
I.S. EN 61378-2:2001 Identical
NBN EN 61378-2 : 2001 Identical
UNE-EN 61378-2:2002 Identical
EN 61378-2:2001 Identical
SN EN 61378-2 : 2001 Identical
DIN EN 61378-2 : 2001 Identical
NF EN 61378-2 : 2001 Identical
IEC 61378-2:2001 Identical

IEC 60270:2000+AMD1:2015 CSV High-voltage test techniques - Partial discharge measurements
IEC 60214:1989 On-load tap-changers
IEC 60076-10:2016 Power transformers - Part 10: Determination of sound levels
IEC 60076-5:2006 Power transformers - Part 5: Ability to withstand short circuit
IEC 60567:2011 Oil-filled electrical equipment - Sampling of gases and analysis of free and dissolved gases - Guidance
IEC 60354:1991 Loading guide for oil-immersed power transformers
IEC 60076-8:1997 Power transformers - Part 8: Application guide
IEC 60146-1-1:2009 Semiconductor converters - General requirements and line commutated converters - Part 1-1: Specification of basic requirements
IEC 60076-3:2013 Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air
IEC 60137:2017 Insulated bushings for alternating voltages above 1000 V
IEC 60076-1:2011 Power transformers - Part 1: General
IEC 60076-2:2011 Power transformers - Part 2: Temperature rise for liquid-immersed transformers
IEC 61378-1:2011 Converter transformers - Part 1: Transformers for industrial applications