BS EN 61378-2:2001
Current
The latest, up-to-date edition.
Convertor transformers Transformers for HVDC applications
Hardcopy , PDF
English
15-08-2001
1 General
1.1 Scope
1.2 Service conditions
2 Normative references
3 Definitions
4 List of variables
5 Ratings
5.1 General
5.2 Rated voltage
5.3 Rated current
5.4 Rated frequency
5.5 Rated power
6 Tolerances
6.1 General
6.2 Short-circuit impedance tolerances
6.3 Guarantees
7 Losses
7.1 General
7.2 No-load loss
7.3 Load loss under rated power-frequency
conditions
7.4 Load loss under service conditions
7.5 Determination of hot-spot temperature
8 Insulation levels
8.1 Line windings
8.2 Valve windings
8.3 Induced voltage level with partial discharge
measurements
9 Sound level
9.1 General
9.2 Guaranteed sound-power levels
9.3 Sound-power level at site
10 Testing
10.1 General
10.2 Tests
10.3 Load-loss measurements
10.4 Factory dielectric tests
10.5 Temperature-rise test
10.6 Load-current test
10.7 Determination of transformer sound-power
level
11 High-frequency modelling
12 Loading of transformer above rating
13 Bushings
13.1 AC bushings
13.2 Valve winding bushings
14 Tap-changer
14.1 General
14.2 Current wave shape
Bibliography
Table 1 - Test conditions for three-winding
transformers
Annex ZA (normative) Normative references to
international publications
with their corresponding
European publications
Applicable to oil-immersed three-phase and single-phase convertor transformers for use in HVDC power transmission.
Committee |
PEL/14
|
DevelopmentNote |
Also numbered as IEC 61378-2 (06/2001) Supersedes 00/203496 DC (10/2004)
|
DocumentType |
Standard
|
Pages |
28
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This part of IEC 61378 applies to oil-immersed three-phase and -single-phase convertor transformers for use in HVDC power transmission. It applies to transformers having two, three or multiple windings. This standard does not apply to convertor transformers for industrial applications (see IEC 61378-1) and to convertor transformers for traction applications (see IEC 60310).
Standards | Relationship |
I.S. EN 61378-2:2001 | Identical |
NBN EN 61378-2 : 2001 | Identical |
UNE-EN 61378-2:2002 | Identical |
EN 61378-2:2001 | Identical |
SN EN 61378-2 : 2001 | Identical |
DIN EN 61378-2 : 2001 | Identical |
NF EN 61378-2 : 2001 | Identical |
IEC 61378-2:2001 | Identical |
IEC 60270:2000+AMD1:2015 CSV | High-voltage test techniques - Partial discharge measurements |
IEC 60214:1989 | On-load tap-changers |
IEC 60076-10:2016 | Power transformers - Part 10: Determination of sound levels |
IEC 60076-5:2006 | Power transformers - Part 5: Ability to withstand short circuit |
IEC 60567:2011 | Oil-filled electrical equipment - Sampling of gases and analysis of free and dissolved gases - Guidance |
IEC 60354:1991 | Loading guide for oil-immersed power transformers |
IEC 60076-8:1997 | Power transformers - Part 8: Application guide |
IEC 60146-1-1:2009 | Semiconductor converters - General requirements and line commutated converters - Part 1-1: Specification of basic requirements |
IEC 60076-3:2013 | Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air |
IEC 60137:2017 | Insulated bushings for alternating voltages above 1000 V |
IEC 60076-1:2011 | Power transformers - Part 1: General |
IEC 60076-2:2011 | Power transformers - Part 2: Temperature rise for liquid-immersed transformers |
IEC 61378-1:2011 | Converter transformers - Part 1: Transformers for industrial applications |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.