• IEC 60076-5:2006

    Current The latest, up-to-date edition.

    Power transformers - Part 5: Ability to withstand short circuit

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Language(s):  English - French, English, French, Spanish, Castilian

    Published date:  07-02-2006

    Publisher:  International Electrotechnical Committee

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    1 Scope
    2 Normative references
    3 Requirements with regard to ability to withstand short
      circuit
      3.1 General
      3.2 Overcurrent conditions
    4 Demonstration of ability to withstand short circuit
      4.1 Thermal ability to withstand short circuit
      4.2 Ability to withstand the dynamic effects of short
          circuit
    Annex A (informative) Theoretical evaluation of the ability
                          to withstand the dynamic effects of
                          short circuit
    Annex B (informative) Definition of similar transformer

    Abstract - (Show below) - (Hide below)

    Identifies the requirements for power transformers to sustain without damage the effects of overcurrents originated by external short circuits. Describes the calculation procedures used to demonstrate the thermal ability of a power transformer to withstand such overcurrents and both the special test and the theoretical evaluation method used to demonstrate the ability to withstand the relevant dynamic effects.

    General Product Information - (Show below) - (Hide below)

    Development Note Supersedes 95/203532 DC. (06/2004) Stability Date: 2018. (09/2017)
    Document Type Standard
    Publisher International Electrotechnical Committee
    Status Current
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    BS EN 62475:2010 High-current test techniques. Definitions and requirements for test currents and measuring systems
    BS IEC 60076-15:2015 Power transformers Gas-filled power transformers
    BS EN 60076-13:2006 Power transformers Self-protected liquid-filled transformers
    BS EN 50329 : 2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - TRACTION TRANSFORMERS
    09/30187488 DC : DRAFT AUG 2009 BS EN 60076-16 - POWER TRANSFORMERS - PART 16: TRANSFORMERS FOR WIND TURBINES APPLICATION
    I.S. EN 60726:2003 DRY-TYPE POWER TRANSFORMERS
    CEI EN 60076-14 : 2014 POWER TRANSFORMERS - PART 14: LIQUID-IMMERSED POWER TRANSFORMERS USING HIGH-TEMPERATURE INSULATION MATERIALS
    CEI EN 60076-11 : 2006 POWER TRANSFORMERS - PART 11: DRY-TYPE TRANSFORMERS
    CEI EN 62475 : 2011 HIGH-CURRENT TEST TECHNIQUES - DEFINITIONS AND REQUIREMENTS FOR TEST CURRENTS AND MEASURING SYSTEMS
    UNE-EN 50541-1:2012 Three phase dry-type distribution transformers 50 Hz, from 100 kVA to 3 150 kVA, with highest voltage for equipment not exceeding 36 kV - Part 1: General requirements
    UNE-EN 61378-1:2012 Convertor transformers -- Part 1: Transformers for industrial applications
    12/30263868 DC : 0 BS EN 60076-14 - POWER TRANSFORMERS - PART 14: LIQUID-IMMERSED POWER TRANSFORMERS USING HIGH-TEMPERATURE INSULATION MATERIALS
    KTA 3705 : 2013(R2017) SWITCHGEAR FACILITIES, TRANSFORMERS AND DISTRIBUTION NETWORKS FOR THE ELECTRICAL POWER SUPPLY OF THE SAFETY SYSTEM IN NUCLEAR POWER PLANTS
    07/30167951 DC : 0 BS EN 60076-1 - POWER TRANSFORMERS - PART 1: GENERAL
    BS EN 60076-6:2008 Power transformers Reactors
    BS EN 60310:2016 Railway applications. Traction transformers and inductors on board rolling stock
    IEEE C57.32-2015 IEEE Standard for Requirements, Terminology, and Test Procedures for Neutral Grounding Devices
    CEI EN 61378-2 : 2002 CONVERTOR TRANSFORMERS - PART 2: TRANSFORMERS FOR HVDC APPLICATIONS
    I.S. EN 60076-11:2004 POWER TRANSFORMERS - PART 11: DRY-TYPE TRANSFORMERS
    I.S. EN 60076-16:2011 POWER TRANSFORMERS - PART 16: TRANSFORMERS FOR WIND TURBINES APPLICATIONS (IEC 60076-16:2011)
    I.S. EN 62271-212:2017 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 212: COMPACT EQUIPMENT ASSEMBLY FOR DISTRIBUTION SUBSTATION (CEADS)
    NF EN 60076-16 : 2012 POWER TRANSFORMERS - PART 16: TRANSFORMERS FOR WIND TURBINES APPLICATION
    IEC 60214-2:2004 Tap-changers - Part 2: Application guide
    NF EN 60076-13 : 2007 POWER TRANSFORMERS - PART 13: SELF-PROTECTED LIQUID-FILLED TRANSFORMERS
    IEC TS 60076-14:2009 Power transformers - Part 14: Design and application of liquid-immersed power transformers using high-temperature insulation materials
    UNE-EN 62271-212:2017 High-voltage switchgear and controlgear - Part 212: Compact Equipment Assembly for Distribution Substation (CEADS)
    PD ISO/TR 18569:2004 Safety of machinery. Guidelines for the understanding and use of safety of machinery standards.
    11/30253145 DC : 0 BS EN 62271-202 ED2 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 202: HIGH-VOLTAGE/LOW-VOLTAGE PREFABRICATED SUBSTATION
    EN 60076-11:2004 Power transformers - Part 11: Dry-type transformers
    EN 60204-11:2000/corrigendum:2010 SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES - PART 11: REQUIREMENTS FOR HV EQUIPMENT FOR VOLTAGES ABOVE 1000 V A.C. OR 1500 V D.C. AND NOT EXCEEDING 36 KV
    EN 62271-212:2017 High-voltage switchgear and controlgear - Part 212: Compact Equipment Assembly for Distribution Substation (CEADS)
    EN 50541-1:2011 Three phase dry-type distribution transformers 50 Hz, from 100 kVA to 3 150 kVA, with highest voltage for equipment not exceeding 36 kV - Part 1: General requirements
    EN 62271-202:2014/AC:2014 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 202: HIGH-VOLTAGE/LOW-VOLTAGE PREFABRICATED SUBSTATION (IEC 62271-202:2014)
    EN 61378-1:2011 Convertor transformers - Part 1: Transformers for industrial applications
    EN 60289:1994/A11:2002 REACTORS
    EN 62475 : 2010 HIGH-CURRENT TEST TECHNIQUES - DEFINITIONS AND REQUIREMENTS FOR TEST CURRENTS AND MEASURING SYSTEMS
    EN 60726:2003 Dry-type power transformers
    16/30336914 DC : 0 BS EN 60076-57-129 ED 1.0 - CONVERTOR TRANSFORMERS - PART 57-129: TRANSFORMERS FOR HVDC APPLICATIONS
    17/30331680 DC : 0 BS ISO 18095 - CONDITION MONITORING AND DIAGNOSTICS OF POWER TRANSFORMERS
    02/205931 DC : DRAFT MAY 2002 IEC 60214-2. ED.1 - TAP CHANGERS - PART 2: APPLICATION GUIDE
    13/30256030 DC : 0 BS IEC 62695 ED 1.0 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - TRACTION TRANSFORMERS
    BS EN 60076-14:2013 Power transformers Liquid-immersed power transformers using high-temperature insulation materials
    BS 7806:1995 Dry-type power transformers
    BS EN 50541-1:2011 Three phase dry-type distribution transformers 50 Hz, from 100 kVA to 3150 kVA, with highest voltage for equipment not exceeding 36 kV General requirements
    BS EN 61800-4:2003 Adjustable speed electrical power drive systems General requirements. Rating specifications for a.c. power drive systems above 1000 V a.c. and not exceeding 35 kV
    02/211941 DC : 0 IEC 60076-14 ED.1 - GUIDE FOR THE DESIGN AND APPLICATION OF LIQUID-IMMERSED POWER TRANSFORMERS USING HIGH-TEMPERATURE INSULATION MATERIALS
    BS IEC 61378-3:2015 Converter transformers Application guide
    08/30178668 DC : DRAFT FEB 2008 BS EN 61378-1 - CONVERTER TRANSFORMERS - PART 1: TRANSFORMERS FOR INDUSTRIAL APPLICATIONS
    NF EN 60289 : 96 AMD 11 2002 REACTORS
    CEI EN 60076-16 : 2012 POWER TRANSFORMERS - PART 16: TRANSFORMERS FOR WIND TURBINES APPLICATIONS
    IEC 62695:2014 Railway applications - Fixed installations - Traction transformers
    CEI 14-41 : 2011 TAP-CHANGERS - PART 2: APPLICATION GUIDE
    IEC 60092-303:1980 Electrical installations in ships - Part 303: Equipment - Transformers for power and lighting
    I.S. EN 60076-13:2006 POWER TRANSFORMERS - PART 13: SELF-PROTECTED LIQUID-FILLED TRANSFORMERS
    IEC 60137:2017 Insulated bushings for alternating voltages above 1000 V
    BS EN 60137:2017 Insulated bushings for alternating voltages above 1000 V
    I.S. EN 62271-202:2014 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 202: HIGH-VOLTAGE/LOW-VOLTAGE PREFABRICATED SUBSTATION
    BS EN 60204-11 : 2001 SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES - PART 11: REQUIREMENTS FOR HV EQUIPMENT FOR VOLTAGES ABOVE 1000 V A.C. OR 1500 V D.C. AND NOT EXCEEDING 36 KV
    IEC 60076-7:2018 Power transformers - Part 7: Loading guide for mineral-oil-immersed power transformers
    CEI 14-42 : 2011 CONVERTER TRANSFORMERS - PART 3: APPLICATION GUIDE
    IEC 61378-3:2015 Converter transformers - Part 3: Application guide
    CEI EN 61378-1 : 2012 CONVERTOR TRANSFORMERS - PART 1: TRANSFORMERS FOR INDUSTRIAL APPLICATIONS
    NF EN 60076-6 : 2008 POWER TRANSFORMERS - PART 6: REACTORS
    NF EN 50329 : 2005 AMD 1 2011 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - TRACTION TRANSFORMERS
    ISO/TR 18569:2004 Safety of machinery Guidelines for the understanding and use of safety of machinery standards
    15/30297998 DC : 0 BS EN 62271-212 ED 1.0 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 212: COMPACT EQUIPMENT ASSEMBLY FOR DISTRIBUTION SUBSTATION (CEADS)
    17/30354643 DC : 0 BS EN 62933-2-1 - ELECTRIC ENERGY STORAGE (ESS) SYSTEMS - PART 2-1: UNIT PARAMETERS AND TESTING METHODS - GENERAL SPECIFICATION
    I.S. EN ISO 14224:2016 PETROLEUM, PETROCHEMICAL AND NATURAL GAS INDUSTRIES - COLLECTION AND EXCHANGE OF RELIABILITY AND MAINTENANCE DATA FOR EQUIPMENT (ISO 14224:2016)
    IEC 60137:2017 RLV Insulated bushings for alternating voltages above 1000 V
    VDE 0532-20 : 1994 REACTORS
    VDE 0532-42 : 2001 CONVERTOR TRANSFORMERS - PART 2: TRANSFORMERS FOR HVDC APPLICATIONS
    BS IEC 60092-303:1980 Electrical installation in ships Equipment. Transformers for power and lighting
    BS 5622-1:1979 Guide for insulation co-ordination Terms, definitions, principles and rules
    I.S. EN 60076-1:2011 POWER TRANSFORMERS - PART 1: GENERAL (IEC 60076-1:2011)
    UNE-EN 60137:2011 Insulated bushings for alternating voltages above 1 000 V
    BS EN 60076-16:2011 Power transformers Transformers for wind turbines applications
    BS 171-1:1978 Power transformers General
    CEI EN 50541-1 : 2011 THREE PHASE DRY-TYPE DISTRIBUTION TRANSFORMERS 50 HZ, FROM 100 KVA TO 3150 KVA, WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 1: GENERAL REQUIREMENTS
    14/30271248 DC : 0 BS EN 60310 ED 4.0 - RAILWAY APPLICATIONS - TRACTION TRANSFORMERS AND INDUCTORS ON BOARD ROLLING STOCK
    CCS GUIDELINE E-07 : DEC 2017 TRANSFORMERS
    BS EN 50327:2003 Railway applications. Fixed installations. Harmonisation of the rated values for converter groups and tests on converter groups
    UNE-EN 60076-14:2014 Power transformers - Part 14: Liquid-immersed power transformers using high-temperature insulation materials
    IEC/IEEE 60076-57-129:2017 Power transformers - Part 57-129: Transformers for HVDC applications
    05/30133866 DC : DRAFT MAY 2005 IEC 60076-6 - POWER TRANSFORMERS - PART 6: REACTORS
    04/30111589 DC : 0
    IEC TS 60076-23:2018 Power transformers - Part 23: DC magnetic bias suppression devices
    BS EN 60289:1995 Reactors
    EN IEC 62933-2-1:2018 Electrical energy storage (EES) systems - Part 2-1: Unit parameters and testing methods - General specification
    I.S. EN IEC 62933-2-1:2018 ELECTRICAL ENERGY STORAGE (EES) SYSTEMS - PART 2-1: UNIT PARAMETERS AND TESTING METHODS - GENERAL SPECIFICATION
    I.S. EN 60310:2016 RAILWAY APPLICATIONS - TRACTION TRANSFORMERS AND INDUCTORS ON BOARD ROLLING STOCK
    EN 60137:2017 Insulated bushings for alternating voltages above 1 000 V
    PREN 50541-1 : DRAFT 2009 THREE PHASE DRY-TYPE DISTRIBUTION TRANSFORMERS 50 HZ, FROM 100 TO 3150 KVA, WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 1: GENERAL REQUIREMENTS AND REQUIREMENTS FOR DRY TYPE TRANSFORMERS WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV
    I.S. EN 60076-6:2008 POWER TRANSFORMERS - PART 6: REACTORS
    IEC 62032:2012 Guide for the Application, Specification and Testing of Phase-Shifting Transformers
    IEC 62933-2-1:2017 Electrical energy storage (EES) systems - Part 2-1: Unit parameters and testing methods - General specification
    IEC 60204-11:2000 Safety of machinery - Electrical equipment of machines - Part 11: Requirements for HV equipment for voltages above 1 000 V a.c. or 1 500 V d.c. and not exceeding 36 kV
    IEC 61892-3:2012 Mobile and fixed offshore units - Electrical installations - Part 3: Equipment
    I.S. EN 60204-11:2000 SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES PART 11: REQUIREMENTS FOR HV EQUIPMENT FOR VOLTAGES ABOVE 1000 V A.C. OR 1500 V D.C. AND NOT EXCEEDING 36 KV
    IEC 61378-2:2001 Convertor transformers - Part 2: Transformers for HVDC applications
    UNE-EN 62271-202:2015 High-voltage switchgear and controlgear - Part 202: High-voltage/low-voltage prefabricated substation
    IEC 60076-13:2006 Power transformers - Part 13: Self-protected liquid-filled transformers
    IEC 61800-4:2002 Adjustable speed electrical power drive systems - Part 4: General requirements - Rating specifications for a.c. power drive systems above 1 000 V a.c. and not exceeding 35 kV
    ISO 14224:2016 Petroleum, petrochemical and natural gas industries Collection and exchange of reliability and maintenance data for equipment
    BS 223:1985 Specification for bushings for alternating voltages above 1000 V
    EN 50532:2010 Compact Equipment Assembly for Distribution Substations (CEADS)
    DD IEC TS 60076-14 : DRAFT 2009 POWER TRANSFORMERS - PART 14: DESIGN AND APPLICATION OF LIQUID-IMMERSED POWER TRANSFORMERS USING HIGH-TEMPERATURE INSULATION MATERIALS
    09/30211604 DC : 0 BS EN 50541-1 - THREE PHASE DRY-TYPE DISTRIBUTION TRANSFORMERS 50 HZ, FROM 100 TO 3150 KVA, WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 1: GENERAL REQUIREMENTS AND REQUIREMENTS FOR DRY TYPE TRANSFORMERS WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV
    BS EN 60076-11:2004 Power transformers Dry-type transformers
    I.S. EN 50532:2010 COMPACT EQUIPMENT ASSEMBLY FOR DISTRIBUTION SUBSTATIONS (CEADS)
    BS EN 61378-1:2011 Convertor transformers Transformers for industrial applications
    UNE-EN 60076-16:2012 Power transformers - Part 16: Transformers for wind turbines applications
    BS EN 60076-1:2011 Power transformers General
    BS EN 60726:2003 Dry-type power transformers
    CEI 14-15 : 2006 POWER TRANSFORMERS - PART 7: LOADING GUIDE FOR OIL-IMMERSED POWER TRANSFORMERS
    PD IEC/TR 60787:2007 Application guide for the selection of high-voltage current-limiting fuse-links for transformer circuits
    16/30318517 DC : 0 BS EN 60137 ED. 7.0 - INSULATED BUSHINGS FOR ALTERNATING VOLTAGES ABOVE 1000 V
    UNE-IEC 60076-7:2010 Power transformers - Part 7: Loading guide for oil-immersed power transformers
    ISO 18095:2018 Condition monitoring and diagnostics of power transformers
    CEI EN 60076-1 : 2015 POWER TRANSFORMERS - PART 1: GENERAL
    I.S. EN 50541-1:2011 THREE PHASE DRY-TYPE DISTRIBUTION TRANSFORMERS 50 HZ, FROM 100 KVA TO 3150 KVA, WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 1: GENERAL REQUIREMENTS
    CEI EN 60076-6 : 2015 POWER TRANSFORMERS - PART 6: REACTORS
    IEC 60076-15:2015 Power transformers - Part 15: Gas-filled power transformers
    BS EN 62271-212:2017 High-voltage switchgear and controlgear Compact Equipment Assembly for Distribution Substation (CEADS)
    IEC 61378-1:2011 Converter transformers - Part 1: Transformers for industrial applications
    98/705686 DC : DRAFT MAR 1998 PREN 13135-1 - CRANES - SAFETY - DESIGN - REQUIREMENTS FOR EQUIPMENT - PART 1: ELECTROTECHNICAL EQUIPMENT
    08/30195018 DC : DRAFT DEC 2008 BS EN 60204-33 - SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES - PART 33: REQUIREMENTS FOR SEMICONDUCTOR FABRICATION EQUIPMENT
    BS EN 50532:2010 Compact equipment assembly for distribution substations (CEADS)
    UNE-EN 60076-1:2013 Power transformers - Part 1: General
    IEC 60076-6:2007 Power transformers - Part 6: Reactors
    IEC 61330:1995 High-voltage/low voltage prefabricated substations
    IEC 60076-1:2011 Power transformers - Part 1: General
    IEC 62475:2010 High-current test techniques - Definitions and requirements for test currents and measuring systems
    IEC 62271-212:2016 High-voltage switchgear and controlgear - Part 212: Compact Equipment Assembly for Distribution Substation (CEADS)
    IEC 62271-202:2014 High-voltage switchgear and controlgear - Part 202: High-voltage/ low-voltage prefabricated substation
    09/30202403 DC : 0 BS EN 50532 - COMPACT EQUIPMENT ASSEMBLY FOR DISTRIBUTION SUBSTATIONS (CEADS)
    UNE-EN 50532:2011 Compact Equipment Assembly for Distribution Substations (CEADS)
    IEC 60310:2016 Railway applications - Traction transformers and inductors on board rolling stock
    IEC 60076-14:2013 Power transformers - Part 14: Liquid-immersed power transformers using high-temperature insulation materials
    07/30153021 DC : 0 BS IEC 60204-33 - SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES - PART 33: REQUIREMENTS FOR SEMICONDUCTOR FABRICATION EQUIPMENT
    EN 60076-16:2011 Power transformers - Part 16: Transformers for wind turbines applications
    CEI EN 60076-13 : 2007 POWER TRANSFORMERS - PART 13: SELF PROTECTED LIQUID FILLED TRANSFORMERS
    BS EN 61378-2:2001 Convertor transformers Transformers for HVDC applications
    CEI EN 60310 : 2016 RAILWAY APPLICATIONS - TRACTION TRANSFORMERS AND INDUCTORS ON BOARD ROLLING STOCK
    12/30275045 DC : 0 BS EN 60076-15 - POWER TRANSFORMERS - PART 15: GAS-FILLED POWER TRANSFORMER
    BS IEC 61892-3:2012 Mobile and fixed offshore units. Electrical installations Equipment
    16/30349321 DC : 0 BS EN 60076-11 ED 2.0 - POWER TRANSFORMERS - PART 11: DRY-TYPE TRANSFORMERS
    IEC TR 60787:2007 Application guide for the selection of high-voltage current- limiting fuse-links for transformer circuits
    04/30117440 DC : DRAFT JUL 2004 IEC 60076-13. ED.1 - POWER TRANSFORMERS - PART 13: SELF-PROTECTED LIQUID FILLED TRANSFORMERS
    UNE-EN 62475:2012 High-current test techniques - Definitions and requirements for test currents and measuring systems
    I.S. EN 62475:2010 HIGH-CURRENT TEST TECHNIQUES - DEFINITIONS AND REQUIREMENTS FOR TEST CURRENTS AND MEASURING SYSTEMS
    C88-16 Power transformers and reactors
    IEEE C57.135-2011 IEEE Guide for the Application, Specification, and Testing of Phase-Shifting Transformers
    I.S. EN 60076-14:2013 POWER TRANSFORMERS - PART 14: LIQUIDIMMERSED POWER TRANSFORMERS USING HIGH-TEMPERATURE INSULATION MATERIALS (IEC 60076-14:2013 (EQV))
    I.S. EN 60137:2017 INSULATED BUSHINGS FOR ALTERNATING VOLTAGES ABOVE 1000 V
    I.S. EN 50329:2007 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - TRACTION TRANSFORMERS
    I.S. EN 61378-1:2011 CONVERTOR TRANSFORMERS - PART 1: TRANSFORMERS FOR INDUSTRIAL APPLICATIONS (IEC 61378-1:2011)
    CEI EN 60137 : 2009 INSULATED BUSHINGS FOR ALTERNATING VOLTAGES ABOVE 1000 V
    CEI EN 61800-4 : 2003 ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 4: GENERAL REQUIREMENTS - RATING SPECIFICATIONS FOR A/C/ POWER DRIVE SYSTEMS ABOVE 1000 V A.C. AND NOT EXCEEDING 35 KV
    I.S. EN 61800-4:2003 ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 4: GENERAL REQUIREMENTS - RATING SPECIFICATIONS FOR A.C. POWER DRIVE SYSTEMS ABOVE 1000 V A.C. AND NOT EXCEEDING 35 KV
    IEC 60137 REDLINE : 7ED 2017 INSULATED BUSHINGS FOR ALTERNATING VOLTAGES ABOVE 1000 V
    02/203840 DC : DRAFT MAY 2002 IEC 60204-1/ED.5.0 - SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES - PART 1: GENERAL REQUIREMENTS
    IEC 60076-16:2011 Power transformers - Part 16: Transformers for wind turbine applications
    02/714212 DC : DRAFT DEC 2002 IEC 62271-202 ED.1 - HIGH VOLTAGE/LOW VOLTAGE PREFABRICATED SUBSTATIONS
    BS EN ISO 14224:2016 Petroleum, petrochemical and natural gas industries. Collection and exchange of reliability and maintenance data for equipment
    BS EN 62271-202:2014 High-voltage switchgear and controlgear High-voltage/low-voltage prefabricated substation
    EN 50327 : 2003 AMD 1 2005 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - HARMONISATION OF THE RATED VALUES FOR CONVERTER GROUPS AND TESTS ON CONVERTER GROUPS
    EN 61378-2:2001 Convertor transformers - Part 2: Transformers for HVDC applications
    EN 50329:2003/A1:2010 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - TRACTION TRANSFORMERS
    EN 60076-6:2008 Power transformers - Part 6: Reactors
    EN 60076-13 : 2006 POWER TRANSFORMERS - PART 13: SELF-PROTECTED LIQUID-FILLED TRANSFORMERS
    EN 61330:1996 High-voltage/low-voltage prefabricated substations
    EN 61800-4:2003 Adjustable speed electrical power drive systems - Part 4: General requirements - Rating specifications for a.c. power drive systems above 1 000 V a.c. and not exceeding 35 kV
    EN 60076-1:2011 POWER TRANSFORMERS - PART 1: GENERAL (IEC 60076-1:2011)
    EN 60076-14:2013 Power transformers - Part 14: Liquid-immersed power transformers using high-temperature insulation materials
    EN 60310:2016/AC:2018-03 RAILWAY APPLICATIONS - TRACTION TRANSFORMERS AND INDUCTORS ON BOARD ROLLING STOCK (IEC 60310:2016/COR1:2018)
    CEI 18-58 : 2013 MOBILE AND FIXED OFFSHORE UNITS - ELECTRICAL INSTALLATIONS - PART 3: EQUIPMENT
    BS 4944(1994) : 1994 AMD 8405 REACTORS

    Standards Referencing This Book - (Show below) - (Hide below)

    AS IEC 62475:2019 High-current test techniques - Definitions and requirements for test currents and measuring systems
    IEC 60076-8:1997 Power transformers - Part 8: Application guide
    IEC 60076-3:2013 Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air
    IEC 60076-1:2011 Power transformers - Part 1: General
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective