BS EN 61535 : 2009
Current
The latest, up-to-date edition.
INSTALLATION COUPLERS INTENDED FOR PERMANENT CONNECTION IN FIXED INSTALLATIONS
Hardcopy , PDF
English
01-01-2009
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements
5 General notes on tests
6 Ratings
7 Classification
8 Marking and documentation
9 Dangerous compatibility
10 Protection against electric shock
11 Terminals, terminations and connectable conductors
12 Construction
13 Protection against harmful ingress of solid foreign
objects and against harmful ingress of water
14 Insulation resistance and electric strength
15 Construction of contacts
16 Temperature rise
17 Breaking capacity
18 Forces necessary to disengage the parts of the
installation coupler
19 Cables and their connection
20 Mechanical strength
21 Resistance to heat and ageing
22 Screws, current-carrying parts and connections
23 Clearances, creepage distances and distances through
solid insulation
24 Resistance to abnormal heat and to tracking
25 Resistance to rusting
Annex A (normative) - Routine Earth (PE) continuity tests
Annex B (normative) - Test circuits for temperature rise
test
Annex C (normative) - Number of sets of test samples used
for the tests and sequence of tests for each set
Annex D (informative) - Guide to use
Bibliography
Annex ZA (normative) - Special national conditions
Annex ZB (normative) - Normative references to international
publications with their corresponding European
publications
Pertains to two up to five wire installation couplers including earth, if provided, with a rated voltage up to and including 500 V a.c. and a rated connecting capacity up to and including 10 mm[2] for permanent connection in indoor electrical installations.
Committee |
PEL/23
|
DevelopmentNote |
Supersedes BS 61535(2006) & 07/30161792 DC. (09/2009) 2009 Edition Re-Issued in April 2013 & incorporates AMD 1 2013. Supersedes 11/30235073 DC. (04/2013)
|
DocumentType |
Standard
|
Pages |
54
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
Standards | Relationship |
EN 61535:2009/A1:2013 | Identical |
IEC 61535:2009+AMD1:2012 CSV | Identical |
BS 7671(2008) : 2018 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
BS 8488(2009) : 2009 | PREFABRICATED WIRING SYSTEMS INTENDED FOR PERMANENT CONNECTION IN FIXED INSTALLATIONS - SPECIFICATION |
BS 7671(2008) : 2008 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
IEC 60112:2003+AMD1:2009 CSV | Method for the determination of the proof and the comparative tracking indices of solid insulating materials |
IEC 60998-2-3:2002 | Connecting devices for low-voltage circuits for household and similar purposes - Part 2-3: Particular requirements for connecting devices as separate entities with insulation-piercing clamping units |
IEC 60364-4-41:2005+AMD1:2017 CSV | Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock |
IEC TR 60083:2015 | Plugs and socket-outlets for domestic and similar general use standardized in member countries of IEC |
IEC 60695-2-11:2014 | Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) |
IEC 60068-2-31:2008 | Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens |
IEC 60050-442:1998 | International Electrotechnical Vocabulary (IEV) - Part 442: Electrical accessories |
EN 60112 : 2003 AMD 1 2009 | METHOD FOR THE DETERMINATION OF THE PROOF AND THE COMPARATIVE TRACKING INDICES OF SOLID INSULATING MATERIALS |
IEC 60999-1:1999 | Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm2 up to 35 mm2 (included) |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
EN 61032:1998 | Protection of persons and equipment by enclosures - Probes for verification |
EN 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
EN 60999-1:2000 | Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm² up to 35 mm² (included) |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
IEC 61032:1997 | Protection of persons and equipment by enclosures - Probes for verification |
IEC 60364-7-713:2013 | Low-voltage electrical installations - Part 7-713: Requirements for special installations or locations - Furniture |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 60364-5-52:2009 | Low-voltage electrical installations - Part 5-52: Selection and erection of electrical equipment - Wiring systems |
EN 60695-2-11:2014 | Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) (IEC 60695-2-11:2014) |
EN 60068-2-31:2008 | ENVIRONMENTAL TESTING - PART 2-31: TESTS - TEST EC: ROUGH HANDLING SHOCKS, PRIMARILY FOR EQUIPMENT-TYPE SPECIMENS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.