• BS EN 61558-2-16 : 2009

    Current The latest, up-to-date edition.

    SAFETY OF TRANSFORMERS, REACTORS, POWER SUPPLY UNITS AND SIMILAR PRODUCTS FOR SUPPLY VOLTAGES UP TO 1100 V - PART 2-16: PARTICULAR REQUIREMENTS AND TESTS FOR SWITCH MODE POWER SUPPLY UNITS AND TRANSFORMERS FOR SWITCH MODE POWER SUPPLY UNITS

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  01-01-2009

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 Scope
    2 Normative references
    3 Terms and definitions
    4 General requirements
    5 General notes on tests
    6 Ratings
    7 Classification
    8 Marking and other information
    9 Protection against electric shock
    10 Change of input voltage setting
    11 Output voltage and output current under load
    12 No-load output voltage
    13 Short circuit voltage
    14 Heating
    15 Short-circuit and overload protection
    16 Mechanical strength
    17 Protection against harmful ingress of dust, solid objects
       and moisture
    18 Insulation resistance, dielectric strength and leakage
       current
    19 Construction
    20 Components
    21 Internal wiring
    22 Supply connection and other external flexible cables or
       cords
    23 Terminals for external conductors
    24 Provisions for protective earthing
    25 Screws and connections
    26 Creepage distances, clearances and distances through
       insulation
    27 Resistance to heat, fire and tracking
    28 Resistance to rusting
    Annexes
    Annex K (normative) - Insulated winding wires
    Annex AA (informative) - Partial discharge (PD) test
    Annex BB (normative) - Particular requirements for associated
             transformers for use in switch mode power supplies
             with internal frequencies > 500 Hz
    Annex ZA (normative) - Normative references to international
             publications with their corresponding European
             publications

    Abstract - (Show below) - (Hide below)

    Describes the safety of switch mode power supply units and transformers for switch mode power supply units.

    General Product Information - (Show below) - (Hide below)

    Committee PEL/96
    Development Note Supersedes BS EN 61558-2-17 & 06/30046204 DC. (01/2010) 2009 Edition Re-Issued in February 2014 & incorporates AMD 1 2013. (03/2014)
    Document Type Standard
    Publisher British Standards Institution
    Status Current
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60950-1:2005+AMD1:2009+AMD2:2013 CSV Information technology equipment - Safety - Part 1: General requirements
    IEC 61558-2-13:2009 Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-13: Particular requirements and tests for auto transformers and power supply units incorporating auto transformers
    IEC 61558-2-1:2007 Safety of power transformers, power supplies, reactors and similar products - Part 2-1: Particular requirements and tests for separating transformers and power supplies incorporating separating transformers for general applications
    IEC 60664-4:2005 Insulation coordination for equipment within low-voltage systems - Part 4: Consideration of high-frequency voltage stress
    EN 61558-2-4:2009 Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-4: Particular requirements and tests for isolating transformers and power supply units incorporating isolating transformers
    EN 61558-2-13:2009 Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-13: Particular requirements and tests for auto transformers and power supply units incorporating auto transformers
    IEC 60364-4-41:2005+AMD1:2017 CSV Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock
    IEC 61558-2-4:2009 Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-4: Particular requirements and tests for isolating transformers and power supply units incorporating isolating transformers
    IEC 60601-1:2005+AMD1:2012 CSV Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
    EN 61558-1:2005/A1:2009 SAFETY OF POWER TRANSFORMERS, POWER SUPPLIES, REACTORS AND SIMILAR PRODUCTS - PART 1: GENERAL REQUIREMENTS AND TESTS
    EN 60317-56:2017 Specifications for particular types of winding wires - Part 56: Solderable fully insulated (FIW) zero-defect polyurethane enamelled round copper wire, class 180
    HD 60364-4-41:2017/A11:2017 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-41: PROTECTION FOR SAFETY - PROTECTION AGAINST ELECTRIC SHOCK
    EN 60950-1:2006/A2:2013 INFORMATION TECHNOLOGY EQUIPMENT - SAFETY - PART 1: GENERAL REQUIREMENTS (IEC 60950-1:2005/A2:2013, MODIFIED)
    IEC 61558-2-6:2009 Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers
    IEC 60317-56:2017 Specifications for particular types of winding wires - Part 56: Solderable fully insulated (FIW) zero-defect polyurethane enamelled round copper wire, class 180
    IEC 60851-5:2008+AMD1:2011 CSV Winding wires - Test methods - Part 5: Electrical properties
    IEC 61558-1:2017 Safety of transformers, reactors, power supply units and combinations thereof - Part 1: General requirements and tests
    EN 61558-2-1:2007 Safety of power transformers, power supplies, reactors and similar products - Part 2-1: Particular requirements and tests for separating transformers and power supplies incorporating separating transformers for general applications
    IEC 60851-3:2009+AMD1:2013 CSV Winding wires - Test methods - Part 3: Mechanical properties
    EN 60317-43:1997/A1:2010 SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES - PART 43: AROMATIC POLYIMIDE TAPE WRAPPED ROUND COPPER WIRE, CLASS 240
    EN 61558-2-6:2009 Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers
    IEC 60317-0-7:2017 Specifications for particular types of winding wires - Part 0-7: General requirements - Fully insulated (FIW) zero-defect enamelled round copper wire
    EN 61010-1:2010 Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
    EN 60664-4:2006/corrigendum:2006 INSULATION COORDINATION FOR EQUIPMENT WITHIN LOW-VOLTAGE SYSTEMS - PART 4: CONSIDERATION OF HIGH-FREQUENCY VOLTAGE STRESS
    IEC 60317-43:1997+AMD1:2010 CSV Specifications for particular types of winding wires - Part 43: Aromatic polyimide type wrapped round copper wire, class 240
    IEC 61204-7:2016 EXV LOW-VOLTAGE SWITCH MODE POWER SUPPLIES - PART 7: SAFETY REQUIREMENTS
    IEC 61010-1:2010+AMD1:2016 CSV Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
    EN 60851-5:2008/A1:2011 WINDING WIRES - TEST METHODS - PART 5: ELECTRICAL PROPERTIES (IEC 60851-5:2008)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective