BS EN 61753-031-2:2014
Current
The latest, up-to-date edition.
Fibre optic interconnecting devices and passive components. Performance standard Non-connectorized single-mode 1xN and 2xN non-wavelength-selective branching devices for Category C. Controlled environment
Hardcopy , PDF
English
30-11-2014
1 Scope
2 Normative references
3 Test
4 Test report
5 Performance requirements
Annex A (normative) - A and U requirements of
1 x N and 2 x N NWBDs
Annex B (normative) - Sample size
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Defines the minimum initial tests and measurement requirements and severities which a non-wavelength selective branching device (NWBD) should satisfy in order to be categorized as meeting the requirement of this IEC standard.
Committee |
GEL/86/2
|
DevelopmentNote |
Supersedes 11/30245080 DC. (11/2014)
|
DocumentType |
Standard
|
Pages |
24
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
IEC 61753-031-2:2014 contains the minimum initial tests and measurement requirements and severities which a non-wavelength selective branching device (NWBD) should satisfy in order to be categorized as meeting the requirement of this IEC standard. The requirements cover balanced bidirectional non-connectorized single-mode 1 x N and 2 x N non wavelength-selective branching devices for use in an IEC Category C environment (N is the number of branching ports), especially but not exclusively used for PON application. For balanced NWBD two attenuation and uniformity performance classes are considered:
- class A (premium class) which meets more restrictive requirements (i.e. for extended reach PON application) and
- class B (standard class) for standard application (i.e. normal reach PON application). The requirements also cover unbalanced bidirectional non-connectorized single-mode, non-wavelength-selective branching devices; however, the specifications of unbalanced branching devices are limited to 1 x 2 and 2 x 2 devices because they are the most commonly used. Keywords: non-wavelength selective branching device (NWBD), IEC Category C environment
Standards | Relationship |
IEC 61753-031-2:2014 | Identical |
EN 61753-031-2:2014 | Identical |
IEC 61300-3-20:2001 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-20: Examinations and measurements - Directivity of fibre optic branching devices |
EN 61300-2-18:2005 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-18: Tests - Dry heat - High temperature endurance |
IEC 61300-3-2:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-2: Examination and measurements - Polarization dependent loss in a single-mode fibre optic device |
IEC 61300-3-28:2012 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-28: Examinations and measurements - Transient loss |
EN 61300-2-1:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-1: Tests - Vibration (sinusoidal) |
EN 61300-2-17:2011 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-17: Tests - Cold |
EN 60793-2-50:2016 | Optical fibres - Part 2-50: Product specifications - Sectional specification for class B single-mode fibres |
IEC 61300-3-3:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-3: Examinations and measurements - Active monitoring of changes in attenuation and return loss |
IEC 61300-2-1:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-1: Tests - Vibration (sinusoidal) |
EN 61300-3-3:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-3: Examinations and measurements - Active monitoring of changes in attenuation and return loss |
IEC 61300-2-9:2017 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-9: Tests - Shock |
EN 61300-2-22:2007 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-22: Tests - Change of temperature |
EN 61300-2-44:2013 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-44: Tests - Flexing of the strain relief of fibre optic devices |
EN 60875-1:2015 | Fibre optic interconnecting devices and passive components - Non-wavelength-selective fibre optic branching devices - Part 1: Generic specification |
IEC 61300-2-17:2010 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-17: Tests - Cold |
IEC 61753-1:2007 | Fibre optic interconnecting devices and passive components performance standard - Part 1: General and guidance for performance standards |
EN 61753-1:2007 | Fibre optic interconnecting devices and passive components performance standard - Part 1: General and guidance for performance standards |
IEC 61300-2-14:2012 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-14: Tests - High optical power |
EN 61300-3-7:2012 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-7: Examinations and measurements - Wavelength dependence of attenuation and return loss of single mode components |
IEC 61300-3-7:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-7: Examinations and measurements - Wavelength dependence of attenuation and return loss of single mode components |
IEC 61300-2-18:2005 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-18: Tests - Dry heat - High temperature endurance |
IEC 61300-2-22:2007 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-22: Tests - Change of temperature |
EN 61300-3-2:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-2: Examinations and measurements - Polarization dependent loss in a single-mode fibre optic device |
IEC 61300-3-6:2008 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-6: Examinations and measurements - Return loss |
EN 61300-2-14:2013 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-14: Tests - High optical power |
EN 61300-3-6:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-6: Examinations and measurements - Return loss |
EN 61300-2-4:1997 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-4: Tests - Fibre/cable retention |
IEC 61300-2-42:2014 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-42: Tests - Static side load for strain relief |
EN 61300-3-28:2012 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-28: Examinations and measurements - Transient loss |
IEC 60793-2-50:2015 | Optical fibres - Part 2-50: Product specifications - Sectional specification for class B single-mode fibres |
IEC 61300-2-44:2013 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-44: Tests - Flexing of the strain relief of fibre optic devices |
IEC 61300-2-4:1995 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-4: Tests - Fibre/cable retention |
EN 61300-2-42:2014 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-42: Tests - Static side load for strain relief |
EN 61300-3-20:2001/corrigendum:2002 | FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS - BASIC TEST AND MEASUREMENT PROCEDURES - PART 3-20: EXAMINATIONS AND MEASUREMENTS - DIRECTIVITY OF FIBRE OPTIC BRANCHING DEVICES |
IEC 61300-2-19:2012 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-19: Tests - Damp heat (steady state) |
EN 61300-2-19:2013 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-19: Tests - Damp heat (steady state) |
IEC 60875-1:2015 | Fibre optic interconnecting devices and passive components - Non-wavelength-selective fibre optic branching devices - Part 1: Generic specification |
EN 61300-2-9:2017 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-9: Tests - Shock |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.