BS EN 61753-031-3:2015
Current
The latest, up-to-date edition.
Fibre optic interconnecting devices and passive components. Performance standard Non-connectorized single-mode 1×N and 2×N non-wavelength-selective branching devices for Category U. Uncontrolled environment
Hardcopy , PDF
English
31-03-2015
1 Scope
2 Normative references
3 Test
4 Test report
5 Performance requirements
Annex A (normative) - A and U requirements
of 1 x N and 2 x N NWBDs
Annex B (normative) - Sample size
Bibliography
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Defines the minimum initial tests and measurement requirements and severities which a non-wavelength selective branching device (NWBD) should satisfy in order to be categorized as meeting the requirement of this standard.
Committee |
GEL/86/2
|
DevelopmentNote |
Supersedes 10/30228493 DC. (03/2015)
|
DocumentType |
Standard
|
Pages |
24
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This part of IEC61753 contains the minimum initial tests and measurement requirements and severities which a non-wavelength selective branching device (NWBD) should satisfy in order to be categorized as meeting the requirements of this standard. The requirements cover balanced bidirectional non-connectorized single-mode 1×N and 2×N non-wavelength-selective branching devices for use in an IEC categoryU environment (N is the number of branching ports), especially but not exclusively used for PON application. For balanced NWBD two attenuation and uniformity performance classes are considered: class A (premium class) which meets more restrictive requirements (i.e. for extended reach PON application) and class B (standard class) for standard application (i.e. for normal reach PON application). The requirements also cover unbalanced, bidirectional, non-connectorized, single-mode, non-wavelength-selective branching devices; however, the specifications of unbalanced branching devices are limited to 1×2 and 2×2 devices because they are the most commonly used.
Standards | Relationship |
EN 61753-031-3:2015 | Identical |
IEC 61753-031-3:2014 | Identical |
EN 61300-2-5:2011 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-5: Tests - Torsion |
IEC 61300-3-20:2001 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-20: Examinations and measurements - Directivity of fibre optic branching devices |
EN 61300-2-18:2005 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-18: Tests - Dry heat - High temperature endurance |
IEC 61300-3-2:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-2: Examination and measurements - Polarization dependent loss in a single-mode fibre optic device |
IEC 61300-3-28:2012 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-28: Examinations and measurements - Transient loss |
EN 61300-2-1:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-1: Tests - Vibration (sinusoidal) |
EN 61300-2-17:2011 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-17: Tests - Cold |
EN 60793-2-50:2016 | Optical fibres - Part 2-50: Product specifications - Sectional specification for class B single-mode fibres |
IEC 61300-3-3:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-3: Examinations and measurements - Active monitoring of changes in attenuation and return loss |
IEC 61300-2-1:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-1: Tests - Vibration (sinusoidal) |
EN 61300-3-3:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-3: Examinations and measurements - Active monitoring of changes in attenuation and return loss |
IEC 61300-2-9:2017 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-9: Tests - Shock |
EN 61300-2-22:2007 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-22: Tests - Change of temperature |
EN 61300-2-44:2013 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-44: Tests - Flexing of the strain relief of fibre optic devices |
EN 60875-1:2015 | Fibre optic interconnecting devices and passive components - Non-wavelength-selective fibre optic branching devices - Part 1: Generic specification |
IEC 61300-2-17:2010 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-17: Tests - Cold |
IEC 61753-1:2007 | Fibre optic interconnecting devices and passive components performance standard - Part 1: General and guidance for performance standards |
EN 61753-1:2007 | Fibre optic interconnecting devices and passive components performance standard - Part 1: General and guidance for performance standards |
IEC 61300-2-46:2006 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-46: Tests - Damp heat, cyclic |
IEC 61300-2-5:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-5: Tests - Torsion |
IEC 61300-2-14:2012 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-14: Tests - High optical power |
EN 61300-3-7:2012 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-7: Examinations and measurements - Wavelength dependence of attenuation and return loss of single mode components |
IEC 61300-3-7:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-7: Examinations and measurements - Wavelength dependence of attenuation and return loss of single mode components |
IEC 61300-2-18:2005 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-18: Tests - Dry heat - High temperature endurance |
IEC 61300-2-22:2007 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-22: Tests - Change of temperature |
EN 61300-3-2:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-2: Examinations and measurements - Polarization dependent loss in a single-mode fibre optic device |
IEC 61300-3-6:2008 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-6: Examinations and measurements - Return loss |
EN 61300-2-14:2013 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-14: Tests - High optical power |
EN 61300-3-6:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-6: Examinations and measurements - Return loss |
EN 61300-2-4:1997 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-4: Tests - Fibre/cable retention |
IEC 61300-2-42:2014 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-42: Tests - Static side load for strain relief |
EN 61300-3-28:2012 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-28: Examinations and measurements - Transient loss |
IEC 60793-2-50:2015 | Optical fibres - Part 2-50: Product specifications - Sectional specification for class B single-mode fibres |
IEC 61300-2-44:2013 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-44: Tests - Flexing of the strain relief of fibre optic devices |
IEC 61300-2-4:1995 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-4: Tests - Fibre/cable retention |
EN 61300-2-42:2014 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-42: Tests - Static side load for strain relief |
EN 61300-3-20:2001/corrigendum:2002 | FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS - BASIC TEST AND MEASUREMENT PROCEDURES - PART 3-20: EXAMINATIONS AND MEASUREMENTS - DIRECTIVITY OF FIBRE OPTIC BRANCHING DEVICES |
IEC 60875-1:2015 | Fibre optic interconnecting devices and passive components - Non-wavelength-selective fibre optic branching devices - Part 1: Generic specification |
EN 61300-2-9:2017 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-9: Tests - Shock |
EN 61300-2-46:2006 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-46: Tests - Damp heat cyclic |