INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Classification
5 Characteristics
6 Marking and other product information
7 Standard conditions for operation in service and
for installation
8 Conditions for construction and operation
9 Tests
Annex A (normative) - Number of samples to
be submitted and test sequences to
be applied for verification of
conformity for type F RCCBs
Annex B (normative) - Number of samples to
be submitted and test sequences to
be applied for verification of
conformity for Type F RCBOs
Annex C (normative) - Number of samples to
be submitted and test sequences to
be applied for verification of
conformity for Type B RCCBs
Annex D (normative) - Number of samples to
be submitted and test sequences to
be applied for verification of
conformity for Type B RCBOs
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Annex ZB (normative) - Special national conditions
Annex ZZ (informative) - Coverage of Essential
Requirements of EU Directives
Bibliography
Defines requirements and tests for Type F and Type B RCDs (Residual current devices).
Committee |
PEL/23
|
DevelopmentNote |
Supersedes 12/30257788 DC. (05/2013)
|
DocumentType |
Standard
|
Pages |
48
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
The scope of IEC 61008-1 and IEC 61009-1 applies with the following additions. IEC 62423:2009 specifies requirements and tests for Type F and Type B RCDs (Residual Current Devices). Requirements and tests given in this standard are in addition to the requirements of Type A residual current devices. This standard can only be used together with IEC 61008-1 and IEC 61009-1. Type F RCCBs (Residual Current Circuit Breaker) and Type F RCBOs (Residual current Circuit Breaker with Overcurrent protection) with rated frequency 50 Hz or 60 Hz are intended for installations when frequency inverters are supplied between phase and neutral or phase and earthed middle conductor and are able to provide protection in case of alternating residual sinusoidal at the rated frequency, pulsating direct residual currents and composite residual currents that may occur. Type B RCCBs and Type B RCBOs are able to provide protection in case of alternating residual sinusoidal currents up to 1 000 Hz, pulsating direct residual currents and smooth direct residual currents. This second edition cancels and replaces the first edition published in 2007 and constitutes a technical revision. The main changes from the first edition are as follows:
- requirements and tests for Type F RCD have been introduced;
- requirements and test for two-pole Type B RCD have been introduced;
- new additional requirements and tests for Type B RCDs have been introduced to cover requirements for Type F too. The contents of the corrigendum of December 2011 have been included in this copy.
Standards | Relationship |
EN 62423:2012 | Identical |
IEC 62423:2009/COR1:2011 | Identical |
BS 7671(2008) : 2018 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
BS 7671(2008) : 2008 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
CISPR 14-1:2016 | Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission |
IEC TS 60479-1:2005+AMD1:2016 CSV | Effects of current on human beings and livestock - Part 1: Generalaspects |
EN 61543:1995/A2:2006 | RESIDUAL CURRENT-OPERATED PROTECTIVE DEVICES (RCDS) FOR HOUSEHOLD AND SIMILAR USE - ELECTROMAGNETIC COMPATIBILITY |
IEC 61009-2-1:1991 | Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBO's) - Part 2-1: Applicability of the general rules to RCBO's functionally independent of line voltage |
IEC 61543:1995 | Residual current-operated protective devices (RCDs) for household and similar use - Electromagnetic compatibility |
2004/108/EC : 2004 | DIRECTIVE 2004/108/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 15 DECEMBER 2004 ON THE APPROXIMATION OF THE LAWS OF THE MEMBER STATES RELATING TO ELECTROMAGNETIC COMPATIBILITY AND REPEALING DIRECTIVE 89/336/EC |
IEC 61009-2-2:1991 | Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBO's) - Part 2-2: Applicability of the general rules to RCBO's functionally dependent on line voltage |
IEC 61008-2-2:1990 | Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCB's). Part 2-2: Applicability of the general rules to RCCB's functionally dependent on line voltage |
IEC 61008-2-1:1990 | Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCB's). Part 2-1: Applicability of the general rules to RCCB's functionally independent of line voltage |
IEC TS 60479-2:2007 | Effects of current on human beings and livestock - Part 2: Special aspects |
EN 55014-1:2017 | Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.