• There are no items in your cart

BS EN ISO 16017-2:2003

Current

Current

The latest, up-to-date edition.

Indoor, ambient and workplace air. Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography Diffusive sampling

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

05-08-2003

€306.17
Excluding VAT

Foreword
1 Scope
2 Normative references
3 Principle
4 Reagents and materials
5 Apparatus
6 Sample tube conditioning
7 Sampling
8 Procedure
   8.1 Safety precautions
   8.2 Desorption and analysis
   8.3 Calibration
   8.4 Determination of sample concentration
   8.5 Determination of desorption efficiency
   8.6 Calibration of uptake rate
9 Calculations
10 Interferences
11 Performance characteristics
12 Test report
13 Quality control
Annex A (informative) Operating principles of diffusive
        sampling
Annex B (informative) Description of sorbent types
Annex C (informative) Guidance on sorbent selection
Annex D (informative) Guidance on sorbent use
Annex E (informative) Summary of data on overall uncertainty,
        precision, bias and storage
Bibliography

Provides general guidance for the sampling and analysis of volatile organic compounds (VOCs) in air. It is applicable to indoor, ambient and workplace air.

Committee
EH/2/5
DevelopmentNote
Supersedes 99/563451 DC (06/2003) Reviewed and confirmed by BSI, November 2007. (10/2007)
DocumentType
Standard
Pages
46
PublisherName
British Standards Institution
Status
Current
Supersedes

This part of ISO 16017 gives general guidance for the sampling and analysis of volatile organic compounds (VOCs) in air. It is applicable to indoor, ambient and workplace air.

This part of ISO 16017 is applicable to a wide range of vOCs, including hydrocarbons, halogenated hydrocarbons, esters, glycol ethers, ketones and alcohols. A number of sorbents1) are recommended for the sampling of these VOCs, each sorbent having a different range of applicability. very polar compounds generally require derivatisation; very low boiling compounds are only partially retained by the sorbents and can only be estimated qualitatively. Semi-volatile compounds are fully retained by the sorbents, but may only be partially recovered.

This part of ISO 16017 is applicable to the measurement of airborne vapours of VOCs in a mass concentration range of approximately 0,002 mg/m3 to 100 mg/m3 individual organic for an exposure time of 8 h, or 0,3 µg/m3 to 300 µg/m3 individual organic for an exposure time of four weeks.

The upper limit of the useful range is set by the sorptive capacity of the sorbent used and by the linear dynamic range of the gas chromatograph column and detector or by the sample splitting capability of the analytical instrumentation used. The lower limit of the useful range depends on the noise level of the detector and on blank levels of analyte and/or interfering artefacts on the sorbent tubes. Artefacts are typically sub-nanogram for well-conditioned Tenax GR and carbonaceous sorbents such as Carbopack/Carbotrap type materials, carbonized molecular sieves such as Spherocarb and pure charcoals. Artefacts are typically at low nanogram levels for Tenax TA and at 5 ng to 50 ng levels for other porous polymers such as Chromosorbs and Porapaks.

12/30248026 DC : 0 BS 8576 - GUIDANCE ON INVESTIGATIONS FOR GROUND GAS - PERMANENT GASES AND VOLATILE ORGANIC COMPOUNDS (VOCS)
BS 8576:2013 Guidance on investigations for ground gas. Permanent gases and Volatile Organic Compounds (VOCs)

VDI 2119 Blatt 4:1997-08 Measurement of Particulate Precipitations - Microscopic differentiation and size fractionated determination of particle deposition on adhesive collection plates - Sigma-2 sampler
EN 838:2010 Workplace exposure - Procedures for measuring gases and vapours using diffusive samplers - Requirements and test methods
EN 482:2012+A1:2015 Workplace exposure - General requirements for the performance of procedures for the measurement of chemical agents
EN 13528-1:2002 Ambient air quality - Diffusive samplers for the determination of concentrations of gases and vapours - Requirements and test methods - Part 1: General requirements
EN 13528-2:2002 Ambient air quality - Diffusive samplers for the determination of concentrations of gases and vapours - Requirements and test methods - Part 2: Specific requirements and test methods
ISO 6145-5:2009 Gas analysis — Preparation of calibration gas mixtures using dynamic volumetric methods — Part 5: Capillary calibration devices
ISO 16000-1:2004 Indoor air — Part 1: General aspects of sampling strategy
ISO 6145-4:2004 Gas analysis Preparation of calibration gas mixtures using dynamic volumetric methods Part 4: Continuous syringe injection method
ISO 6145-3:1986 Gas analysis Preparation of calibration gas mixtures Dynamic volumetric methods Part 3: Periodic injections into a flowing gas stream
ISO 6145-1:2003 Gas analysis Preparation of calibration gas mixtures using dynamic volumetric methods Part 1: Methods of calibration
ISO 6141:2015 Gas analysis Contents of certificates for calibration gas mixtures
ISO 6145-6:2017 Gas analysis — Preparation of calibration gas mixtures using dynamic methods — Part 6: Critical flow orifices

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.