BS EN ISO 7198:2017
Current
The latest, up-to-date edition.
Cardiovascular implants and extracorporeal systems. Vascular prostheses. Tubular vascular grafts and vascular patches
Hardcopy , PDF
English
31-03-2017
Committee |
CH/150/2
|
DevelopmentNote |
Supersedes 14/30281557 DC, BS ISO 7198 & BS EN 12006-2. (03/2017)
|
DocumentType |
Standard
|
Pages |
70
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
1.1 This International Standard specifies requirements for the evaluation of vascular prostheses and requirements with respect to nomenclature, design attributes and information supplied by the manufacturer, based upon current medical knowledge. Guidance for the development of in vitro test methods is included in an informative annex to this International Standard. This International Standard can be considered as a supplement to ISO14630:2012, which specifies general requirements for the performance of non-active surgical implants.
NOTE Due to the variations in the design of implants covered by this International Standard and, in some cases, due to the relatively recent development of some of these implants (e.g. bioabsorbable vascular prostheses, cell based tissue engineered vascular prostheses), acceptable standardized in vitro tests and clinical results are not always available. As further scientific and clinical data become available, appropriate revision of this International Standard will be necessary.
1.2 This International Standard is applicable to sterile tubular vascular grafts implanted by direct visualization surgical techniques as opposed to fluoroscopic or other non-direct imaging (e.g. computerized tomography or magnetic resonance imaging), intended to replace, bypass, or form shunts between segments of the vascular system in humans and vascular patches intended for repair and reconstruction of the vascular system.
1.3 Vascular prostheses that are made of synthetic textile materials and synthetic non-textile materials are within the scope of this International Standard.
1.4 While vascular prostheses that are made wholly or partly of materials of non-viable biological origin, including tissue engineered vascular prostheses are within the scope, this International Standard does not address sourcing, harvesting, manufacturing and all testing requirements for biological materials. It is further noted that different regulatory requirements might exist for tissues from human and animal sources.
1.5 Compound, coated, composite, and externally reinforced vascular prostheses are within the scope of this standard.
1.6 Endovascular prostheses implanted using catheter delivery and non-direct visualization are excluded from the scope of this International Standard. This International Standard includes information on the development of appropriate test methods for graft materials, referenced in ISO25539-1 for materials used in the construction of endovascular prostheses (i.e. stent-grafts).
NOTE Requirements for endovascular prostheses are specified in ISO25539-1.
1.7 The valve component of valved conduits constructed with a tubular vascular graft component, and the combination of the valved component and the tubular vascular graft component, are excluded from the scope of this International Standard. This International Standard can be helpful in identifying the appropriate evaluation of the tubular vascular graft component of a valved conduit but specific requirements and testing are not described for these devices.
1.8 Cardiac and pericardial patches, vascular stents, accessory devices such as anastomotic devices, staplers, tunnelers and sutures, and pledgets are excluded from the scope of this International Standard.
NOTE Requirements for vascular stents are specified in ISO25539-2.
1.9 Requirements regarding cell seeding are excluded from the scope of this International Standard. Tissue engineered vascular prostheses that contain or are manufactured using cells present many distinct manufacturing (e.g. aseptic processing, cell seeding, etc.) and testing issues than those produced with synthetic or non-viable biological materials. The in vitro testing requirements that are outlined in this International Standard can be a useful guide for certain testing requirements for these cell-based products.
1.10 Pharmacological aspects of drug-eluting or drug-coated vascular prostheses are not addressed in this International Standard.
NOTE Requirements for vascular device-drug combination products are specified in ISO12417-1.
1.11 Degradation, tissue ingrowth and/or tissue replacement, and other time-dependent aspects of absorbable vascular prostheses are not addressed in the standard.
Standards | Relationship |
ISO 7198:2016 | Identical |
EN ISO 7198:2017 | Identical |
ISO 25539-2:2012 | Cardiovascular implants Endovascular devices Part 2: Vascular stents |
EN ISO 14937:2009 | Sterilization of health care products - General requirements for characterization of a sterilizing agent and the development, validation and routine control of a sterilization process for medical devices (ISO 14937:2009) |
EN ISO 10993-5:2009 | Biological evaluation of medical devices - Part 5: Tests for in vitro cytotoxicity (ISO 10993-5:2009) |
EN ISO 10993-2:2006 | Biological evaluation of medical devices - Part 2: Animal welfare requirements (ISO 10993-2:2006) |
ISO 14160:2011 | Sterilization of health care products Liquid chemical sterilizing agents for single-use medical devices utilizing animal tissues and their derivatives Requirements for characterization, development, validation and routine control of a sterilization process for medical devices |
ISO 11135:2014 | Sterilization of health-care products — Ethylene oxide — Requirements for the development, validation and routine control of a sterilization process for medical devices |
EN ISO 10993-11:2009 | Biological evaluation of medical devices - Part 11: Tests for systemic toxicity (ISO 10993-11:2006) |
EN ISO 10993-17:2009 | Biological evaluation of medical devices - Part 17: Establishment of allowable limits for leachable substances (ISO 10993-17:2002) |
ISO 13485:2016 | Medical devices Quality management systems Requirements for regulatory purposes |
EN ISO 10993-13:2010 | Biological evaluation of medical devices - Part 13: Identification and quantification of degradation products from polymeric medical devices (ISO 10993-13:2010) |
ISO 14937:2009 | Sterilization of health care products General requirements for characterization of a sterilizing agent and the development, validation and routine control of a sterilization process for medical devices |
EN ISO 10993-9:2009 | Biological evaluation of medical devices - Part 9: Framework for identification and quantification of potential degradation products (ISO 10993-9:2009) |
EN ISO 10993-10:2013 | Biological evaluation of medical devices - Part 10: Tests for irritation and skin sensitization (ISO 10993-10:2010) |
EN ISO 10993-7 : 2008 COR 2009 | BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 7: ETHYLENE OXIDE STERILIZATION RESIDUALS (ISO 10993-7:2008/COR 1:2009) |
EN ISO 10993-4:2017 | Biological evaluation of medical devices - Part 4: Selection of tests for interactions with blood (ISO 10993-4:2017) |
ISO 25539-1:2017 | Cardiovascular implants — Endovascular devices — Part 1: Endovascular prostheses |
CEN ISO/TS 17665-2:2009 | Sterilization of health care products - Moist heat - Part 2: Guidance on the application of ISO 17665-1 (ISO/TS 17665-2:2009) |
EN ISO 11135:2014 | Sterilization of health-care products - Ethylene oxide - Requirements for the development, validation and routine control of a sterilization process for medical devices (ISO 11135:2014) |
EN ISO 10993-3:2014 | Biological evaluation of medical devices - Part 3: Tests for genotoxicity, carcinogenicity and reproductive toxicity (ISO 10993-3:2014) |
ISO 14630:2012 | Non-active surgical implants — General requirements |
EN ISO 10993-6:2016 | Biological evaluation of medical devices - Part 6: Tests for local effects after implantation (ISO 10993-6:2016) |
ISO 12417-1:2015 | Cardiovascular implants and extracorporeal systems — Vascular device-drug combination products — Part 1: General requirements |
EN ISO 11137-2:2015 | Sterilization of health care products - Radiation - Part 2: Establishing the sterilization dose (ISO 11137-2:2013) |
EN ISO 10993-18:2009 | Biological evaluation of medical devices - Part 18: Chemical characterization of materials (ISO 10993-18:2005) |
EN ISO 11137-1:2015 | Sterilization of health care products - Radiation - Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices (ISO 11137-1:2006, including Amd 1:2013) |
EN ISO 14971:2012 | Medical devices - Application of risk management to medical devices (ISO 14971:2007, Corrected version 2007-10-01) |
EN ISO 10993-12:2012 | Biological evaluation of medical devices - Part 12: Sample preparation and reference materials (ISO 10993-12:2012) |
ISO 14155:2011 | Clinical investigation of medical devices for human subjects Good clinical practice |
EN ISO 17665-1:2006 | Sterilization of health care products - Moist heat - Part 1: Requirements for the development, validation and routine control of a sterilization process for medical devices (ISO 17665-1:2006) |
ISO 14971:2007 | Medical devices Application of risk management to medical devices |
ISO 11607-1:2006 | Packaging for terminally sterilized medical devices Part 1: Requirements for materials, sterile barrier systems and packaging systems |
EN ISO 10993-15:2009 | Biological evaluation of medical devices - Part 15: Identification and quantification of degradation products from metals and alloys (ISO 10993-15:2000) |
EN ISO 10993-14:2009 | Biological evaluation of medical devices - Part 14: Identification and quantification of degradation products from ceramics (ISO 10993-14:2001) |
EN ISO 11137-3:2017 | Sterilization of health care products - Radiation - Part 3: Guidance on dosimetric aspects of development, validation and routine control (ISO 11137-3:2017) |
EN ISO 14160:2011 | Sterilization of health care products - Liquid chemical sterilizing agents for single-use medical devices utilizing animal tissues and their derivatives - Requirements for characterization, development, validation and routine control of a sterilization process for medical devices (ISO 14160:2011) |
EN ISO 14630:2012 | Non-active surgical implants - General requirements (ISO 14630:2012) |