BS G 222:1976
Current
The latest, up-to-date edition.
Specification for Efglas type electric cables (metric units)
Hardcopy , PDF
English
30-07-1976
Foreword
Sections
One. General
Two. Efglas cables
Three. Efglasmet cables
Four. Efglasmetsheath cables
Five. Efglaslarge cables
Appendix
A Maximum long-term current ratings for Efglas
cables at an ambient temperature of 220 deg C
Tables
1 Details of Efglas cables
2 Details of Efglasmet cables
3(a) Details of Efglasmetsheath cables
3(b) Details of Du- and Triefglasmetsheath cables
4 Details of Efglaslarge cables
5 Abrasion test weights and minimum length of
abrasion tape
6 Thickness of nickel on copper conductors and
braiding wires
7 Resistance to fluids
Gives the requirements for Efglas type cables for aircraft wiring for continuous use where the maximum stabilized conductor temperature does not exceed 260 degrees C and remain flexible at temperatures down to -70 degrees C. Applies to cables where the potential between conductors or between a conductor and screen or the aircraft structure is less than 600 volts (r.m.s.) and the frequency less than 1600 Hz. Includes maximum long-term current ratings for Efglas cables at an ambient temperature of 220 degrees C.
Committee |
ACE/6
|
DevelopmentNote |
Supersedes 74/73799 DC, 86/75316 DC and BS PD6456(1970). (06/2005) Reviewed and confirmed by BSI, December 2012. (11/2012)
|
DocumentType |
Standard
|
Pages |
16
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
1.1 This British Standard states the requirements for Efglas type cables for aircraft wiring which are suitable for continuous use where the maximum stabilized conductor temperature does not exceed 260 °C. The cables remain flexible at temperatures down to – 70 °C.
1.2 The cables do not support combustion but they do not comply with the requirements of 3G 100 in respect of fire resistance.
1.3 The cables are suitable for use where the potential between conductors or between a conductor and screen or the aircraft structure does not exceed 600 volts (r.m.s.) and the frequency does not exceed 1 600 Hz.
1.4 The maximum current ratings for Efglas cables are shown in Appendix A.
DEFSTAN 02-517(PT4)/2(2008) : 2008 | REQUIREMENTS FOR CABLE, ELECTRIC - PART 4: FLUORINATED MATERIAL INSULATED |
DEFSTAN 00-970(PT1)SEC6/4(2006) : 2006 | DESIGN AND AIRWORTHINESS REQUIREMENTS FOR SERVICE AIRCRAFT - PART 1: COMBAT A/C - SECTION 6: EQUIPMENT |
DEFSTAN 00-970(PT7)SEC7/1(2006) : 2006 | DESIGN AND AIRWORTHINESS REQUIREMENTS FOR SERVICE AIRCRAFT - PART 7: ROTORCRAFT - SECTION 7: INSTALLATIONS |
DEFSTAN 00-970(PT1)SEC6/15(2015) : 2015 | DESIGN AND AIRWORTHINESS REQUIREMENTS FOR SERVICE AIRCRAFT - PART 1: FIXED WING - SECTION 6: EQUIPMENT |
DEFSTAN 00-970(PT1)SEC6/6(2010) : 2010 | DESIGN AND AIRWORTHINESS REQUIREMENTS FOR SERVICE AIRCRAFT - PART 1: FIXED WING - SECTION 6: EQUIPMENT |
DEFSTAN 00-970(PT1)SEC6/12(2014) : 2014 | DESIGN AND AIRWORTHINESS REQUIREMENTS FOR SERVICE AIRCRAFT - PART 1: FIXED WING - SECTION 6: EQUIPMENT |
DEFSTAN 00-970(PT1)SEC6/11(2013) : 2013 | DESIGN AND AIRWORTHINESS REQUIREMENTS FOR SERVICE AIRCRAFT - PART 1: FIXED WING - SECTION 6: EQUIPMENT |
DEFSTAN 00-970(PT1)SEC6/5(2007) : 2007 | DESIGN AND AIRWORTHINESS REQUIREMENTS FOR SERVICE AIRCRAFT - PART 1: COMBAT AIRCRAFT - SECTION 6: EQUIPMENT |
DEFSTAN 00-970(PT1)SEC6/10(2013) : 2013 | DESIGN AND AIRWORTHINESS REQUIREMENTS FOR SERVICE AIRCRAFT - PART 1: FIXED WING - SECTION 6: EQUIPMENT |
DEFSTAN 00-970(PT1)SEC6/14(2015) : 2015 | DESIGN AND AIRWORTHINESS REQUIREMENTS FOR SERVICE AIRCRAFT - PART 1: FIXED WING - SECTION 6: EQUIPMENT |
DEFSTAN 00-970(PT7)SEC2/SUPP6/5(2015) : INTERIM | DESIGN AND AIRWORTHINESS REQUIREMENTS FOR SERVICE AIRCRAFT - PART 7: ROTORCRAFT - SUPPLEMENT 6: EQUIPMENT (SUBPART F) |
DEFSTAN 00-970(PT1)SEC6/13(2014) : 2014 | DESIGN AND AIRWORTHINESS REQUIREMENTS FOR SERVICE AIRCRAFT - PART 1: FIXED WING - SECTION 6: EQUIPMENT |
BS G 225:1979 | Specification for performance of environment-resistant terminal junction modules with removable crimp-type contacts |
DEFSTAN 02-122/1(2002) : INTERIM | REQUIREMENTS FOR CATERING EQUIPMENT |
BS G 192:1965 | Specification for Efglas type electric cables with copper conductors for aircraft |
DEFSTAN 00-970(PT1)SEC6/16(2016) : 2016 | DESIGN AND AIRWORTHINESS REQUIREMENTS FOR SERVICE AIRCRAFT - PART 1: FIXED WING - SECTION 6: EQUIPMENT |
BS G 244:1989 | Code of practice for installation/repair of aircraft electrical interconnection systems |
BS 3G 231:1997 | Specification for conductors for general-purpose aircraft electrical cables and aerospace applications |
BS G 212:1971 | Specification for general requirements for aircraft electrical cables |
BS G 192:1965 | Specification for Efglas type electric cables with copper conductors for aircraft |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.