• BS IEC 60728-12:2017

    Current The latest, up-to-date edition.

    Cable networks for television signals, sound signals and interactive services Electromagnetic compatibility of systems

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  18-09-2017

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    INTRODUCTION
    1 Scope
    2 Normative references
    3 Terms, definitions, symbols and abbreviated terms
    4 Methods of measurement
    5 Performance requirements
    Annex A (informative) - Information on legal requirements
            in some countries
    Annex B (informative) - Frequency ranges of typical safety
            of life services
    Annex C (informative) - Interdependence between the
            maximum allowable field strength and the minimum
            signal level at system outlet
    Annex D (normative) - Measurements at other distances
            than the standard distance of 3 m
    Annex E (informative) - GPS based leakage detection system
            for cable networks
    Bibliography

    Abstract - (Show below) - (Hide below)

    Pertains to the radiation characteristics and immunity to electromagnetic disturbance of cable networks for television signals, sound signals and interactive services and covers the frequency range 0,15 MHz to 3,5 GHz.

    Scope - (Show below) - (Hide below)

    This part of IEC 60728 applies to the radiation characteristics and immunity to electromagnetic disturbance of cable networks for television signals, sound signals and interactive services and covers the frequency range 0,15 MHz to 3,5 GHz.

    NOTE 1 Measurements below 30 MHz are not generally considered useful in the context of cable networks and are difficult to perform in practice.

    This document specifies methods of measurement and EMC performance requirements under operating conditions (in situ) to ensure the ongoing EMC integrity of cable networks.

    Cable networks beyond the system outlets (e.g. the receiver lead, in simplest terms) that begin at the system outlet and end at the input to the subscriber\'s terminal equipment are not covered by this document. Requirements for the electromagnetic compatibility of receiver leads are specified in IEC 60966-2-4, IEC 60966-2-5 and IEC 60966-2-6.

    Cable networks and a wide range of radio services have to coexist. These include, for example, the emergency services, safety of life, broadcasting, aeronautical, radio navigation services and also land, mobile, amateur and cellular radio services. Frequency ranges of typical safety of life services are listed in Annex B. Additional protection for certain services may be required by national regulations. Annex A gives information on legal requirements in certain countries.

    General Product Information - (Show below) - (Hide below)

    Committee EPL/100
    Document Type Standard
    Publisher British Standards Institution
    Status Current

    Standards Referencing This Book - (Show below) - (Hide below)

    CISPR 16-1-4:2010+AMD1:2012+AMD2:2017 CSV Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-4: Radio disturbance and immunity measuring apparatus - Antennas and test sites for radiated disturbance measurements
    IEC 60966-2-6:2016 Radio frequency and coaxial cable assemblies - Part 2-6: Detail specification for cable assemblies for radio and TV receivers - Frequency range 0 MHz to 3 000 MHz, IEC 61169-24 connectors
    CISPR 16-1-1:2015 Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus
    CISPR 32:2015 RLV Electromagnetic compatibility of multimedia equipment - Emission requirements
    IEC 61169-24:2009 Radio-frequency connectors - Part 24: Sectional specification - Radio frequency coaxial connectors with screw coupling, typically for use in 75 Ω cable networks (type F)
    IEC 60966-2-5:2016 Radio frequency and coaxial cable assemblies - Part 2-5: Detail specification for cable assemblies for radio and TV receivers - Frequency range 0 MHz to 1 000 MHz, IEC 61169-2 connectors
    IEC 60966-2-7:2015 Radio frequency and coaxial cable asemblies - Part 2-7: Detail specification for cable assemblies for radio and TV receivers - Frequency range 0 MHz to 3 000 MHz, IEC 61169-47 connectors
    IEC 60966-2-4:2016 Radio frequency and coaxial cable assemblies - Part 2-4: Detail specification for cable assemblies for radio and TV receivers - Frequency range 0 MHz to 3 000 MHz, IEC 61169-2 connectors
    IEC 61169-2:2007 Radio-frenquency connectors - Part 2: Sectional specification - Radio frequency coaxial connectors of type 9,52
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective