• BS IEC 62873-3-2:2016

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Residual current operated circuit-breakers for household and similar use Particular requirements for RCDs with flat quick-connect terminations

    Available format(s):  Hardcopy, PDF

    Superseded date:  27-11-2020

    Language(s):  English

    Published date:  30-09-2016

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    INTRODUCTION
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Classification
    5 Characteristics of RCDs
    6 Marking and other product information
    7 Standard conditions for operation in service
      and for installation
    8 Requirements for construction and operation
    9 Tests
    Bibliography

    Abstract - (Show below) - (Hide below)

    Pertains to RCDs equipped with flat quick-connect terminations consisting of a male tab with nominal width 6,3 mm and thickness 0,8 mm, to be used with a mating female connector for connecting electrical copper conductors according to the manufacturer's instructions, for rated currents up to and including 16 A.

    Scope - (Show below) - (Hide below)

    This part of IEC 62873 applies to RCDs equipped with flat quick-connect terminations consisting of a male tab (see 3.2) with nominal width 6,3 mm and thickness 0,8 mm, to be used with a mating female connector for connecting electrical copper conductors according to the manufacturer\'s instructions, for rated currents up to and including 16 A.

    NOTE The use of RCDS with flat quick-connect terminations for rated currents up to and including 20 A is accepted in BE, FR, IT, ES, PT and US.

    This part of IEC 62873 cannot be used alone but is intended to be applied together with an RCD product standard (IEC 61008-1 or IEC 61009-1) if an RCD is equipped with flat quick-connect terminations.

    The connectable electrical copper conductors are flexible, having a cross-sectional area up to and including 4 mm2, or rigid stranded, having a cross-sectional area up to and including 2,5 mm2 (AWG equal to or greater than 12).

    This part of IEC 62873 applies exclusively to RCDs having male tabs as an integral part of the device.

    General Product Information - (Show below) - (Hide below)

    Committee PEL/23/1
    Development Note Supersedes 13/30283468 DC. (09/2016)
    Document Type Standard
    Publisher British Standards Institution
    Status Superseded
    Superseded By
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 62873-2:2016 Residual current operated circuit-breakers for household and similar use - Part 2: Residual current devices (RCDs) - Vocabulary
    IEC 61210:2010 Connecting devices - Flat quick-connect terminations for electrical copper conductors - Safety requirements
    IEC 61008-1:2010+AMD1:2012+AMD2:2013 CSV Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part1: General rules
    IEC 61009-1:2010+AMD1:2012+AMD2:2013 CSV Residual current operated circuit-breakers with integral overcurrentprotection for household and similar uses (RCBOs) - Part 1: General rules