BS ISO 10094-2:2010
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Pneumatic fluid power. Electro-pneumatic pressure control valves Test methods to determine main characteristics to include in the supplier\'s literature
Hardcopy , PDF
English
30-11-2010
29-11-2021
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and units
5 Test conditions
6 Test procedures
7 Control signal/pressure static-characteristics test at null
forward or relief flow rate
8 Flow/pressure static characteristics test
9 Pressure regulation characteristics test
10 Leakage at null forward flow rate or relief flow rate
characteristic test
11 Dynamic characteristics
12 Presentation of test results
Annex A (informative) - Calculation procedures of gain and
phase lag
Bibliography
Describes the test procedures and a method of presenting the results concerning the parameters which define the main characteristics to be included in the supplier's literature of the electro-pneumatic continuous pressure control valves.
| Committee |
MCE/18/-/5
|
| DevelopmentNote |
Supersedes 09/30196686 DC. (11/2010)
|
| DocumentType |
Standard
|
| Pages |
38
|
| PublisherName |
British Standards Institution
|
| Status |
Superseded
|
| SupersededBy | |
| Supersedes |
This part of ISO10094 specifies the test procedures and a method of presenting the results concerning the parameters which define the main characteristics to be included in the supplier\'s literature of the electro-pneumatic continuous pressure control valves, conforming to ISO10094-1.
The purpose of this part of ISO10094 is
-
to facilitate the comparison by standardizing the test methods and the presentation of the test results, and
-
to assist in the proper application of these components in compressed air systems.
The specified tests are intended to allow comparison between the different types of continuous pressure control valves; these are not production tests to be carried out on each manufactured product.
NOTE1 The tests related to non-electrically modulated pneumatic continuous pressure control valves are specified in ISO6953-2.
NOTE2 The tests related to electro-pneumatic continuous flow control valves are specified in ISO10041-2.
NOTE3 The tests described in this part of ISO10094 are realised on components with an exhaust port vented to the atmosphere.
| Standards | Relationship |
| ISO 10094-2:2010 | Identical |
| ISO 8778:2003 | Pneumatic fluid power — Standard reference atmosphere |
| ISO 5598:2008 | Fluid power systems and components — Vocabulary |
| ISO 10041-2:2010 | Pneumatic fluid power — Electro-pneumatic continuous flow control valves — Part 2: Test methods to determine main characteristics to include in the supplier's literature |
| ISO 6953-1:2015 | Pneumatic fluid power — Compressed air pressure regulators and filter-regulators — Part 1: Main characteristics to be included in literature from suppliers and product-marking requirements |
| ISO 1219-1:2012 | Fluid power systems and components — Graphical symbols and circuit diagrams — Part 1: Graphical symbols for conventional use and data-processing applications |
| ISO 6953-2:2015 | Pneumatic fluid power — Compressed air pressure regulators and filter-regulators — Part 2: Test methods to determine the main characteristics to be included in literature from suppliers |
| ISO 10094-1:2010 | Pneumatic fluid power — Electro-pneumatic pressure control valves — Part 1: Main characteristics to include in the supplier's literature |
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.