BS ISO 3009:2003
Current
The latest, up-to-date edition.
Fire resistance tests. Elements of building construction. Glazed elements
Hardcopy , PDF
English
13-02-2004
Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions and symbols
4 Test equipment
5 Test conditions
6 Test specimen preparation
6.1 General
6.2 Number of specimens
6.3 Size of specimen
6.4 Test construction
7 Application of instrumentation
7.1 Furnace thermocouples (plate thermometer)
7.2 Specimen thermocouples
7.3 Furnace pressure
7.4 Heat flux measurement
7.5 Deflection measurement
8 Test procedure
8.1 Furnace control
8.2 Measurements and observations
9 Performance criteria
10 Validity of the test
11 Expression of results
12 Test report
Annex A (informative) Non-planar elements and test data
application
Annex B (normative) Test specimens - Testing insulated and
uninsulated glazing
Bibliography
Provides test method for determining and assessing the fire resistance performance of both insulated and uninsulated glazed elements of building construction, when those elements are exposed to heating on one face.
Committee |
FSH/22
|
DocumentType |
Standard
|
Pages |
36
|
PublisherName |
British Standards Institution
|
Status |
Current
|
This International Standard provides a test method for determining and assessing the fire resistance performance of both insulated and uninsulated glazed elements of building construction, when those elements are exposed to heating on one face. It is applicable to glazed separating elements such as screens, walls of glass blocks and other light-transmitting assemblies used in vertical, inclined or horizontal orientations, and to all separating elements containing glazing intended to be assessed in accordance with ISO834-1 — except for doors and shutter assemblies, which are intended to be tested in accordance with ISO3008. It is directly applicable to planar elements, but also gives guidance on the testing of non-planar elements such as pyramids.
The application of the test results to other, untested, forms of construction is acceptable only when the construction complies with the field of direct application given in this International Standard or when it is subjected to a field of extended application analysis in accordance with ISO/TR12470.
NOTE Since ISO/TR12470 gives only general guidelines, specific extended application analyses are to be performed only by persons expert in fire-resistant constructions.
Standards | Relationship |
ISO 3009:2003 | Identical |
07/30147204 DC : 0 | BS 476-10 - FIRE TESTS ON BUILDING MATERIALS AND STRUCTURES - PART 10: GUIDE TO THE PRINCIPLES, SELECTION, ROLE AND APPLICATION OF FIRE TESTING AND THEIR OUTPUTS |
BS 476-10:2009 | Fire tests on building materials and structures Guide to the principles, selection, role and application of fire testing and their outputs |
ISO/TR 834-3:2012 | Fire-resistance tests — Elements of building construction — Part 3: Commentary on test method and guide to the application of the outputs from the fire-resistance test |
ISO 6308:1980 | Gypsum plasterboard Specification |
ISO 834-8:2002 | Fire-resistance tests Elements of building construction Part 8: Specific requirements for non-loadbearing vertical separating elements |
ISO 13943:2017 | Fire safety — Vocabulary |
ISO 3008:2007 | Fire-resistance tests Door and shutter assemblies |
ISO/TR 12470:1998 | Fire-resistance tests Guidance on the application and extension of results |
ISO 834-9:2003 | Fire-resistance tests — Elements of building construction — Part 9: Specific requirements for non-loadbearing ceiling elements |
ISO 834-1:1999 | Fire-resistance tests Elements of building construction Part 1: General requirements |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.