• There are no items in your cart

BS ISO 3009:2003

Current

Current

The latest, up-to-date edition.

Fire resistance tests. Elements of building construction. Glazed elements

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

13-02-2004

€271.12
Excluding VAT

Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions and symbols
4 Test equipment
5 Test conditions
6 Test specimen preparation
   6.1 General
   6.2 Number of specimens
   6.3 Size of specimen
   6.4 Test construction
7 Application of instrumentation
   7.1 Furnace thermocouples (plate thermometer)
   7.2 Specimen thermocouples
   7.3 Furnace pressure
   7.4 Heat flux measurement
   7.5 Deflection measurement
8 Test procedure
   8.1 Furnace control
   8.2 Measurements and observations
9 Performance criteria
10 Validity of the test
11 Expression of results
12 Test report
Annex A (informative) Non-planar elements and test data
        application
Annex B (normative) Test specimens - Testing insulated and
        uninsulated glazing
Bibliography

Provides test method for determining and assessing the fire resistance performance of both insulated and uninsulated glazed elements of building construction, when those elements are exposed to heating on one face.

Committee
FSH/22
DocumentType
Standard
Pages
36
PublisherName
British Standards Institution
Status
Current

This International Standard provides a test method for determining and assessing the fire resistance performance of both insulated and uninsulated glazed elements of building construction, when those elements are exposed to heating on one face. It is applicable to glazed separating elements such as screens, walls of glass blocks and other light-transmitting assemblies used in vertical, inclined or horizontal orientations, and to all separating elements containing glazing intended to be assessed in accordance with ISO834-1 — except for doors and shutter assemblies, which are intended to be tested in accordance with ISO3008. It is directly applicable to planar elements, but also gives guidance on the testing of non-planar elements such as pyramids.

The application of the test results to other, untested, forms of construction is acceptable only when the construction complies with the field of direct application given in this International Standard or when it is subjected to a field of extended application analysis in accordance with ISO/TR12470.

NOTE Since ISO/TR12470 gives only general guidelines, specific extended application analyses are to be performed only by persons expert in fire-resistant constructions.

Standards Relationship
ISO 3009:2003 Identical

07/30147204 DC : 0 BS 476-10 - FIRE TESTS ON BUILDING MATERIALS AND STRUCTURES - PART 10: GUIDE TO THE PRINCIPLES, SELECTION, ROLE AND APPLICATION OF FIRE TESTING AND THEIR OUTPUTS
BS 476-10:2009 Fire tests on building materials and structures Guide to the principles, selection, role and application of fire testing and their outputs

ISO/TR 834-3:2012 Fire-resistance tests — Elements of building construction — Part 3: Commentary on test method and guide to the application of the outputs from the fire-resistance test
ISO 6308:1980 Gypsum plasterboard Specification
ISO 834-8:2002 Fire-resistance tests Elements of building construction Part 8: Specific requirements for non-loadbearing vertical separating elements
ISO 13943:2017 Fire safety — Vocabulary
ISO 3008:2007 Fire-resistance tests Door and shutter assemblies
ISO/TR 12470:1998 Fire-resistance tests Guidance on the application and extension of results
ISO 834-9:2003 Fire-resistance tests — Elements of building construction — Part 9: Specific requirements for non-loadbearing ceiling elements
ISO 834-1:1999 Fire-resistance tests Elements of building construction Part 1: General requirements

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.