C22.2 NO. 245-17
Current
The latest, up-to-date edition.
Marine shipboard cable
Hardcopy , PDF
English
01-01-2017
Preface
1 Scope
2 Reference publications
3 General requirements
4 Construction
5 Testing details and performance requirements of cable types
6 Cable type and product markings
Annex A (informative) - Recommended practice for colour code
for control and signal cables
Annex B (informative) - Recommended practice for colour code
for twisted pair cables
Defines the requirements for distribution (power), control, and signal cables, for use aboard marine vessels and fixed and floating offshore drilling or production platforms, that are: a) rated up to 35 kV (ac or dc, phase-to-phase) maximum; b) in single or multi-conductor constructions; c) with or without metal armour; and d) with or without an overall jacket.
DocumentType |
Standard
|
ISBN |
978-1-4883-0893-2
|
Pages |
0
|
PublisherName |
Canadian Standards Association
|
Status |
Current
|
Supersedes |
Preface This is the third edition of CSA C22.2 No. 245, Marine shipboard cable. It supersedes the previous editions published in 2015 and 1995. It is one of a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. This Standard was originally published as a harmonized Standard with Underwriters Laboratories Inc. It is now a non-harmonized CSA Group Standard. This edition includes the following changes: a) changes in the low smoke halogen free compliance which is now in Clause 5.3.10; b) Clause 5.2.4 has been added to clarify the required production tests for cables above 2 kV; c) in Clause 5.3.10, the halogen content is to be calculated for halogen free type only; d) a note has been added in Table 5 to address the testing of cable jacket when the cables diameter is less than 16 AWG; and e) various changes to the values in Table 7. Scope 1.1 This Standard specifies the requirements for distribution (power), control, and signal cables, for use aboard marine vessels and fixed and floating offshore drilling or production platforms, that are a) rated up to 35 kV (ac or dc, phase-to-phase) maximum; b) in single or multi-conductor constructions; c) with or without metal armour; and d) with or without an overall jacket. Cables rated up to 1 kV ac can be rated at 2.8 kV dc. 1.2 The installations described in Clause 1.1 are designed to be installed in accordance with Canadian Electrical Code (CE Code), Part I. Note: Installation of cables is subject to requirements found in industry standards and local regulations. 1.3 In this Standard, \"shall\" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; \"should\" is used to express a recommendation or that which is advised but not required; and \"may\" is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application. 1.4 The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only.
CSA C22.2 No. 38 : 2014 | THERMOSET-INSULATED WIRES AND CABLES |
ASTM B 174 : 2017 : REDLINE | Standard Specification for Bunch-Stranded Copper Conductors for Electrical Conductors |
IEC 60331-2:2009 | Tests for electric cables under fire conditions - Circuit integrity - Part 2: Test method for fire with shock at a temperature of at least 830 °C for cables of rated voltage up to and including 0,6/1,0 kV and with an overall diameter not exceeding 20 mm |
CSA C22.2 No. 123 : 2016 | METAL SHEATHED CABLES |
CSA C22.2 No. 124 : 2016 | MINERAL-INSULATED CABLE |
CSA C68.10 : 2014 | SHIELDED POWER CABLE FOR COMMERCIAL AND INDUSTRIAL APPLICATIONS, 5-46 KV |
NEMA WC 55 : 1992(R1999) | INSTRUMENTATION CABLES AND THERMOCOUPLE WIRE |
NEMA WC 57 : 2014 | CONTROL, THERMOCOUPLE EXTENSION, AND INSTRUMENTATION CABLES |
ASTM B 172 : 2017 : REDLINE | Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Members, for Electrical Conductors |
ASTM B 496 : 2016 : REDLINE | Standard Specification for Compact Round Concentric-Lay-Stranded Copper Conductors |
IEC 60331-23:1999 | Tests for electric cables under fire conditions - Circuit integrity - Part 23: Procedures and requirements - Electric data cables |
CSA C22.2 No. 210 : 2015 | APPLIANCE WIRING MATERIAL PRODUCTS |
C22.2 NO. 75-17 | Thermoplastic insulated wires and cables (Trinational standard with UL 83 and NMX-J-010-ANCE-2017) |
MIL-DTL-24643 Revision C:2009 | Cables, Electric, Low Smoke, Halogen-Free, for Shipboard Use, General Specification for |
IEC 60331-1:2009 | Tests for electric cables under fire conditions - Circuit integrity - Part 1: Test method for fire with shock at a temperature of at least 830 °C for cables of rated voltage up to and including 0,6/1,0 kV and with an overall diameter exceeding 20 mm |
IEC 60331-25:1999 | Tests for electric cables under fire conditions - Circuit integrity - Part 25: Procedures and requirements - Optical fibre cables |
CSA C22.2 No. 2556 : 2015 | WIRE AND CABLE TEST METHODS |
ASTM B 173 : 2017 : REDLINE | Standard Specification for Rope-Lay-Stranded Copper Conductors Having Concentric-Stranded Members, for Electrical Conductors |
IEC 60331-3:2009 | Tests for electric cables under fire conditions - Circuit integrity - Part 3: Test method for fire with shock at a temperature of at least 830 °C for cables of rated voltage up to and including 0,6/1,0 kV tested in a metal enclosure |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.