CAN/CSA-C22.2 NO. 60947-7-3:17
Current
The latest, up-to-date edition.
Low-voltage switchgear and controlgear ? Part 7-3: Ancillary equipment ? Safety requirements for fuse terminal blocks (Trinational standard NMX-J-538/7-3-ANCE with UL 60947-7-3)
Hardcopy , PDF
English, French
01-01-2017
Preface
NATIONAL DIFFERENCES
FOREWORD
INTRODUCTION
1 General
2 Definitions
3 Classification
4 Characteristics
5 Product information
6 Normal service, mounting and transport conditions
7 Constructional and performance requirements
8 Tests
Annex A (normative) - Gauges
Annex B (informative) - Power dissipation values P[V]
and P[VK]
Annex C (normative) - Order of tests and number of
specimens
Annex DVA (normative) - IEC, Canadian, Mexican, and
United States Standard References
Annex DVB (normative)
Bibliography
Pertains to fuse terminal blocks with screw-type or screwless-type clamping units for the connection of rigid (solid or stranded) or flexible copper conductors for the reception of cartridge fuse-links in accordance with IEC 60127-2, intended primarily for industrial or similar use in circuits not exceeding 1000 V a.c., up to 1000 Hz or 1500 V d.c., and having a maximum short-circuit breaking capacity of 1500 A.
DevelopmentNote |
Also numbered as NMX-J-538/7-3-ANCE with UL 60947-7-3. (02/2017)
|
DocumentType |
Standard
|
ISBN |
978-1-77139-994-4
|
Pages |
0
|
PublisherName |
Canadian Standards Association
|
Status |
Current
|
Preface This is the harmonized ANCE, CSA Group, and UL standard for Low-Voltage Switchgear and Controlgear - Part 7-3: Ancillary Equipment - Safety Requirements for Fuse Terminal Blocks. It is the first edition of NMX-J-538/7-3-ANCE, the first edition of CAN/CSA-C22.2 No. 60947-7-3, and the third edition of UL 60947-7-3. This edition of UL 60947-7-3 supersedes the previous edition (s) published on May 6, 2011.? This harmonized standard is based on IEC Publication 60947-7-3: Edition 1 (2002), Low-Voltage Switchgear and Controlgear - Part 7-3: Ancillary Equipment - Safety Requirements for Fuse Terminal Blocks, as revised by corrigendum (March 2003). IEC 60947-7-3 is copyrighted by the IEC.? Scope This part of IEC 60947 applies to fuse terminal blocks with screw-type or screwless-type clamping units for the connection of rigid (solid or stranded) or flexible copper conductors for the reception of cartridge fuse-links in accordance with IEC 60127-2, intended primarily for industrial or similar use in circuits not exceeding 1 000 V a.c., up to 1 000 Hz or 1 500 V d.c., and having a maximum short-circuit breaking capacity of 1 500 A.? They are intended for installation in electrical equipment with enclosures which surround the fuse terminal blocks to such an extent that they are accessible only with the aid of a tool.? For certain applications, for example in control circuits, the fuse terminal blocks may be designed exclusively for short-circuit protection.? NOTE This Standard may be used as a guide for fuse terminal blocks for the reception of special cartridge fuselinks which do not meet the requirements of IEC 60127-2.? The object of this standard is to specify safety requirements and test methods for the mechanical, electrical and thermal characteristics of fuse terminal\'s blocks, to ensure the compatibility between terminal blocks and standardized fuse-links.? This Standard may be used as a guide for? fuse terminal blocks requiring the fixing of special devices to the conductors, for example quick connect terminations or wrapped connections, etc.;? fuse terminal blocks providing direct contact to the conductors by means of edges or points penetrating the insulation, for example insulation displacement connections, etc.? Where applicable in this standard, the term \"clamping unit\" has been used instead of the term \"terminal\". This is taken into account in case of reference to IEC 60947-1.? 1.1DV D2 Modification by adding the following:? This Standard specifies requirements for fuse terminal blocks with screw-type or screwless-type clamping units for the connection of rigid (solid or stranded) or flexible copper conductors for the reception of cartridge fuse-links, in accordance with Annex DVB, National Electrical Code, NFPA 70 (for use in the USA), CSA C22.1-15 Canadian Electrical Code, Part I (for use in Canada), and NOM-001-SEDE, Electrical Installations (Utility) [for use in Mexico].
IEC 60364-4-43:2008 | Low-voltage electrical installations - Part 4-43: Protection for safety - Protection against overcurrent |
IEC 60127-6:2014 | Miniature fuses - Part 6: Fuse-holders for miniature fuse-links |
CAN/CSA-C22.2 NO. 60947-7-1:17 | Low-voltage switchgear and controlgear ? Part 7-1: Ancillary equipment ? Terminal blocks for copper conductors (Trinational standard with NMX-J-538/7-1-ANCE and UL 60947-7-1) |
ISO 3:1973 | Preferred numbers Series of preferred numbers |
IEC 60947-7-1:2009 | Low-voltage switchgear and controlgear - Part 7-1: Ancillary equipment - Terminal blocks for copper conductors |
IEC 60127-1:2006+AMD1:2011+AMD2:2015 CSV | Miniature fuses - Part 1: Definitions for miniature fuses andgeneral requirements for miniature fuse-links |
IEC 60127-2:2014 | Miniature fuses - Part 2: Cartridge fuse-links |
IEC 60715:2017 | Dimensions of low-voltage switchgear and controlgear - Standardized mounting on rails for mechanical support of switchgear, controlgear and accessories |
IEC 61180-2:1994 | High-voltage test techniques for low-voltage equipment - Part 2: Test equipment |
CAN/CSA-C22.2 NO. 60947-1-13 (R2018) | Low-voltage switchgear and controlgear - Part 1: General rules (Tri-national standard, with UL 60947-1 and NMX-J-515-ANCE) |
IEC 60947-1:2007+AMD1:2010+AMD2:2014 CSV | Low-voltage switchgear and controlgear - Part 1: General rules |
NFPA 70 : 2017 | NATIONAL ELECTRICAL CODE |
UL 60947-7-1:4ED 2017-01-27 | Low-voltage switchgear and controlgear - Part 7-1: Ancillary equipment - Terminal blocks for copper conductors |
ISO 4046:1978 | Paper, board, pulp and related terms — Vocabulary |
IEC 61180-1:1992 | High-voltage test techniques for low voltage equipment - Part 1: Definitions, test and procedure requirements |
IEC 60216-1:2013 | Electrical insulating materials - Thermal endurance properties - Part 1: Ageing procedures and evaluation of test results |