POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES ABOVE 36 KV (U[M] = 42 KV) UP TO 150 KV (U[M] = 170 KV)
Hardcopy , PDF
Italian
01-01-2010
28-07-2025
EUROPEAN FOREWORD
PART 1 - General test requirements
PART 2 - Additional test methods
PART 3 - Test requirements for cables with XLPE insulation
and metallic screen and their accessories
PART 4 - Test requirements for cables with XLPE insulation,
metallic screen and metal-laminated sheath and their
accessories
PART 5 - Test requirements for cables with XLPE insulation
and metallic sheath and their accessories
PART 6 - Test requirements for cables with EPR insulation
and metallic screen and their accessories
PART 7 - Test requirements for cables with EPR insulation,
metallic screen and metal-laminated sheath and their
accessories
PART 8 - Test requirements for cables with EPR insulation
and metallic sheath and their accessories
PART 9 - Test requirements for cables with PE or HDPE
insulation and metallic screen and their accessories
PART 10 - Test requirements for cables with PE or HDPE
insulation, metallic screen and metal-laminated sheath
and their accessories
PART 11 - Test requirements for cables with PE or HDPE
insulation and metallic sheath and their accessories
Defines test methods and requirements for power cable systems, cables alone and accessories alone, for fixed installations and for rated voltages above 36 kV (U[m] = 42 kV) up to and including 150 kV (U[m] = 170 kV).
| Committee |
CT 20
|
| DevelopmentNote |
Supersedes CEI 20-66 V1. (02/2017) 2ED 2010 Edition is valid until 27-06-2019. (08/2017)
|
| DocumentType |
Test Method
|
| Pages |
148
|
| PublisherName |
Comitato Elettrotecnico Italiano
|
| Status |
Superseded
|
| SupersededBy | |
| Supersedes |
| Standards | Relationship |
| HD 632 S1:1998 | Identical |
| CEI 20-56 : 2010 | DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV SOMMARIO |
| EN 60229:2008 | Electric cables - Tests on extruded oversheaths with a special protective function |
| CEI 20-50 : 2010 | ELECTRICAL CABLES ADDITIONAL TEST METHODS |
| HD 605 S2:2008/corrigendum:2010 | ELECTRIC CABLES - ADDITIONAL TEST METHODS |
| EN 60332-1-2:2004/A11:2016 | TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-2: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - PROCEDURE FOR 1 KW PRE-MIXED FLAME (IEC 60332-1-2:2004/A1:2015) |
| HD 588.1 : S1 AMD 1 | HIGH VOLTAGE TEST TECHNIQUES - GENERAL DEFINITIONS AND TEST REQUIREMENTS |
| IEC 60183:2015 | Guidance for the selection of high-voltage A.C. cable systems |
| CEI EN 60228 : 2005 | CONDUCTORS OF INSULATED CABLES |
| EN 60230:2002 | Impulse tests on cables and their accessories |
| ISO 48:2010 | Rubber, vulcanized or thermoplastic — Determination of hardness (hardness between 10 IRHD and 100 IRHD) |
| CEI 42-4 : 1997 | TECNICHE DI PROVA AD ALTA TENSIONE - PARTE 1: DEFINIZIONI E PRESCRIZIONI GENERALI RELATIVE ALLE PROVE |
| CEI 20-29 : 2ED 1997 | Insulated cable conductors |
| IEC 60287-1-1:2006+AMD1:2014 CSV | Electric cables - Calculation of the current rating - Part 1-1:Current rating equations (100 % load factor) and calculation of losses - General |