CEI EN 50131-2-5 : 2009
Current
The latest, up-to-date edition.
ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-5: REQUIREMENTS FOR COMBINED PASSIVE INFRARED AND ULTRASONIC DETECTORS
Hardcopy , PDF
English - Italian
01-01-2009
INTRODUCTION
1 Scope
2 Normative references
3 Definitions and abbreviations
4 Functional requirements
5 Marking, identification and documentation
6 Testing
Annex A (normative) - Dimensions & requirements
of the standardised test magnets
Annex B (normative) - General testing matrix
Annex C (informative) - Walk test diagrams
Annex D (normative) - Procedure for calculation
of average temperature difference
Annex E (informative) - Basic detection target
for the basic test of detection capability
Annex F (informative) - Equipment for walk test
velocity control
Annex G (informative) - Immunity to visible and near
infrared radiation - Notes on calibration of the light source
Annex H (informative) - Example list of small tools
Annex I (informative) - Test for resistance to re-orientation
of adjustable mountings
Bibliography
Gives the security grades 1 to 4 (see EN 50131-1), specific or non-specific wired or wire-free detectors, and uses environmental classes I to IV (see EN 50130-5).
Committee |
CT 79
|
DevelopmentNote |
Classificazione CEI 79-58. Supersedes CEI CLC/TS 50131-2-5. (09/2009) An interpretation sheet 2015 exists for CEI EN 50131-2-5, See CEI EN 50131-2-5/IS1. (12/2015)
|
DocumentType |
Standard
|
Pages |
84
|
PublisherName |
Comitato Elettrotecnico Italiano
|
Status |
Current
|
Supersedes |
Standards | Relationship |
EN 50131-2-5:2008 | Identical |
CEI 79-3 : 2012 | ALARM SYSTEMS - PARTICULAR REQUIREMENTS FOR INTRUSION AND HOLD-UP INSTALLATIONS |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
EN 50131-1:2006/A2:2017 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 1: SYSTEM REQUIREMENTS |
EN 50131-6:2017 | Alarm systems - Intrusion and hold-up systems - Part 6: Power supplies |
EN 50130-4:2011/A1:2014 | ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
IEC 60068-2-52:2017 | Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution) |
EN 50130-5:2011 | ALARM SYSTEMS - PART 5: ENVIRONMENTAL TEST METHODS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.