• There are no items in your cart

CEI EN 60670-24 : 2014

Current

Current

The latest, up-to-date edition.

BOXES AND ENCLOSURES FOR ELECTRICAL ACCESSORIES FOR HOUSEHOLD AND SIMILAR FIXED ELECTRICAL INSTALLATIONS - PART 24: PARTICULAR REQUIREMENTS FOR ENCLOSURES FOR HOUSING PROTECTIVE DEVICES AND OTHER POWER DISSIPATING ELECTRICAL EQUIPMENT

Available format(s)

Hardcopy , PDF

Language(s)

English - Italian

Published date

01-01-2014

€170.67
Excluding VAT

Foreword
Introduction
1. Scope
2. Normative references
3. Definitions
4. General requirements
5. General notes on tests
6. Ratings
7. Classification
8. Marking
9. Dimensions
10. Protection against electric shock
11. Provision for earthing
12. Construction
13. Resistance to ageing, protection against ingress
    of solid objects and against harmful ingress of water
14. Insulation resistance and electric strength
15. Mechanical strength
16. Resistance to heat
17. Creepage distances, clearances and distances
     through sealing compound
18. Resistance of insulating material to abnormal
    heat and fire
19. Resistance to tracking
20. Resistance to corrosion
21. Electromagnetic compatibility
Annex AA (normative) - Examples of connecting
                       boxes/enclosures
Annex AA (Normative) - Instructions to be given by the
                       manufacturer of the GP enclosure to the
                       installer how to integrate accessories,
                       and example of calculation
Annex BB (Normative) - Instructions to be given by the
                       manufacturer of the PD enclosure to the
                       installer how to integrate accessories
Bibliography
ANNEX ZA (normative) - Normative references to international
                       publications with their corresponding
                       european publications
ANNEX ZB (normative) - Special national conditions
ANNEX ZC (normative) - A-Deviations

Describes the enclosures and parts of them for housing protective devices and other power dissipating electrical equipment intended to be used with a rated voltage not exceeding 400 V and a total incoming load current not exceeding 125 A for household and similar fixed electrical installations.

Committee
CT 23
DevelopmentNote
Classificazione CEI 23-128. To be read in conjunction with CEI EN 60670-1. (03/2014) New child AMD 11 2023 is added New child AMD 11 2024 is added
DocumentType
Standard
Pages
112
ProductNote
New child AMD 11 2023 is added New child AMD 11 2024 is added
PublisherName
Comitato Elettrotecnico Italiano
Status
Current

Standards Relationship
EN 60670-24:2013 Identical

EN 62262:2002 Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code)
IEC 61009-2-1:1991 Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBO's) - Part 2-1: Applicability of the general rules to RCBO's functionally independent of line voltage
EN 61008-2-1:1994/A11:1998/corrigendum:1999 RESIDUAL CURRENT OPERATED CIRCUIT BREAKERS WITHOUT INTEGRAL OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR USES (RCCBs) - APPLICABILITY OF THE GENERAL RULES TO RCCBs' FUNCTIONALLY INDEPENDENT OF LINE VOLTAGE
CEI 3 : 1998 GRAPHICAL SYMBOLS FOR ELECTRICAL CIRCUITS OF RAILWAY SIGNALLING SYSTEMS
EN 61009-2-1:1994/A11:1998/corrigendum Mar. 1999 RESIDUAL CURRENT OPERATED CIRCUIT BREAKERS WITH INTEGRAL OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR USES (RCBOs) - PART 2-1: APPLICABILITY OF THE GENERAL RULES TO RCBOS' FUNCTIONALLY INDEPENDENT OF LINE VOLTAGE
IEC 62262:2002 Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code)
CEI 23-31 : 1997 SISTEMI DI CANALI METALLICI E LORO ACCESSORI AD USO PORTACAVI E PORTAPPARECCHI
EN 60898-1:2003/A13:2012 ELECTRICAL ACCESSORIES - CIRCUIT BREAKERS FOR OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR INSTALLATIONS - PART 1: CIRCUIT-BREAKERS FOR A.C. OPERATION (IEC 60898-1:2002, MODIFIED)
IEC 60898-1:2015 Electrical accessories - Circuit-breakers for overcurrent protection for household and similar installations - Part 1: Circuit-breakers for a.c. operation
IEC 61008-2-1:1990 Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCB's). Part 2-1: Applicability of the general rules to RCCB's functionally independent of line voltage
IEC 60439-3:1990+AMD1:1993+AMD2:2001 CSV Low-voltage switchgear and controlgear assemblies - Part 3: Particular requirements for low-voltage switchgear and controlgear assemblies intended to be installed in places where unskilled persons have access for their use - Distribution boards
EN 60898-1:2003/A13:2012 ELECTRICAL ACCESSORIES - CIRCUIT BREAKERS FOR OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR INSTALLATIONS - PART 1: CIRCUIT-BREAKERS FOR A.C. OPERATION (IEC 60898-1:2002, MODIFIED)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.