CEN/TR 15276-1:2009
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
Fixed firefighting systems - Condensed aerosol extinguishing systems - Part 1: Requirements and test methods for components
07-03-2023
14-01-2009
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Component requirements
4.1 Condensed aerosol generator
4.2 Solid aerosol-forming compound
4.3 Cooling mechanism
4.4 Ignition device
4.4.1 General
4.4.2 Electrical ignition device
4.4.3 Thermal ignition device
4.4.4 Other methods of ignition device
4.5 End plate and housing
4.6 Extinguishants
5 Condensed aerosol generators requirements
5.1 General
5.2 Extinguishing factor
5.3 Agent distribution
5.4 Discharge time
5.5 Ambient temperature and humidity operation ranges
5.6 Service life
5.7 Shelf life and storage conditions
5.8 Corrosion
5.9 Vibration
5.10 Mechanical shock
5.11 Discharge temperature
5.11.1 General
5.11.2 Casing temperature
5.11.3 Aerosol flow temperature
5.12 Ignition device
5.12.1 General
5.12.2 Electrical ignition device
5.12.3 Thermal ignition device
5.13 Function reliability
5.14 Open fire conditions
5.15 Accessories
5.16 Documentation
6 Marking
7 Test methods
7.1 Conditions
7.2 Samples
7.3 Conformity
7.4 Extinguishing factor determination
7.5 Coverage determination
7.6 Discharge time test
7.7 Temperature and humidity operation range tests
7.7.1 Object of the test
7.7.2 Test procedure
7.7.3 Low temperature Test
7.8 Accelerated ageing test
7.8.1 Test time
7.8.2 Test procedure
7.9 Corrosion test
7.10 Stress corrosion test
7.11 Vibration test
7.12 Impact test
7.12.1 Test procedure
7.12.2 Test apparatus
7.13 Drop test
7.13.1 Impact surface
7.13.2 Procedure
7.13.3 Requirements
7.14 Casing and aerosol flow temperatures test
7.14.1 Casing temperature test
7.14.2 Aerosol flow temperature test
7.15 Ignition performance test
7.16 Function test
7.16.1 Discharge time
7.16.2 Aerosol flow temperatures
7.16.3 Test procedure
7.16.4 Casing temperature test
7.16.5 Discharged mass
7.16.6 Explosive atmosphere actuation test
7.16.7 Requirements
7.17 Heat exposure test
7.17.1 Object of the test
7.17.2 Test procedure
7.17.3 Requirements
7.18 Explosive atmosphere test
7.18.1 Object of the test
7.18.2 Test procedure
7.18.3 Requirements
Annex A (normative) - Extinguishing factor/coverage
test procedure
Bibliography
This document specifies requirements, describes test methods for condensed aerosol extinguishing components and covers solely condensed aerosols. This document is not intended to indicate approval of the extinguishants listed herein by the appropriate authorities, as other extinguishants may be equally acceptable.This document is intended as a standard covering solely condensed aerosol.The condensed aerosol generator typically consists of the following main components:a)solid aerosol-forming compound;b)cooling mechanism;c)ignition device(s);d)end plate discharge outlet(s);e)housing;f)mounting bracket.This document does not cover dispersed aerosols.This document requires, as a precaution, that the room is evacuated and sealed off whenever a generator is activated. Precautions include evacuation of the proximity area, criteria for re-entering and other safeguards as stated in Clause 5 of CEN/TR 15276-2:2009.
Committee |
CEN/TC 191
|
DocumentType |
Technical Report
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Withdrawn
|
SupersededBy |
Standards | Relationship |
PD CEN/TR 15276-1:2009 | Identical |
DIN-Fachbericht CEN/TR 15276-1:2009-05 | Identical |
UNI CEN/TR 15276-1 : 2009 | Identical |
FD CEN/TR 15276-1 : 2009 FD | Identical |
NEN NPR CEN/TR 15276-1 : 2009 | Identical |
S.R. CEN TR 15276-1:2009 | Identical |
PNE-prCEN/TR 15276-1 | Identical |
PD CEN/TR 15276-2:2009 | Fixed firefighting systems. Condensed aerosol extinguishing systems Design, installation and maintenance |
CEN/TR 15276-2:2009 | Fixed firefighting systems - Condensed aerosol extinguishing systems - Part 2: Design, installation and maintenance |
UNI CEN/TR 15276-2 : 2009 | FIXED FIREFIGHTING SYSTEMS - CONDENSED AEROSOL EXTINGUISHING SYSTEMS - PART 2: DESIGN, INSTALLATION AND MAINTENANCE |
S.R. CEN TR 15276-2:2009 | FIXED FIREFIGHTING SYSTEMS - CONDENSED AEROSOL EXTINGUISHING SYSTEMS - PART 2: DESIGN, INSTALLATION AND MAINTENANCE |
ISO 5660-1:2015 | Reaction-to-fire tests Heat release, smoke production and mass loss rate Part 1: Heat release rate (cone calorimeter method) and smoke production rate (dynamic measurement) |
ISO 209:2007 | Aluminium and aluminium alloys — Chemical composition |
CEN/TR 15276-2:2009 | Fixed firefighting systems - Condensed aerosol extinguishing systems - Part 2: Design, installation and maintenance |
EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
ISO 9001:2015 | Quality management systems — Requirements |
EN 60068-2-6:2008 | Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal) |
EN 316:2009 | Wood fibre boards - Definition, classification and symbols |
EN 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.