Resilient, textile and laminate floor coverings - Design, preparation and installation - Part 4: Resilient floor coverings
06-09-2023
18-06-2003
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Exchange of information
5 Materials
5.1 Smoothing compounds or underlayments
5.2 Underlayments
5.3 Underlays
5.4 Selection of floor coverings
6 Subfloors
6.1 General
6.2 Board and strip floors
6.3 Wood blocks
6.4 Particleboard floating floors
6.5 Other bases
6.6 Fabricated substrates
7 Installation
7.1 General
7.2 Inspection of goods
7.3 Existing floor coverings
7.4 Underfloor heating
7.5 Planning of layout
7.6 Temperature during installation
7.7 Adhesives
7.8 Welding
7.9 Stairs
7.10 Skirtings, covings, edges, and dividing strip
7.11 Conductive floor coverings
8 Completion
Bibliography
This Technical Specification provides recommendations for the installation of resilient floor coverings. It covers products composed of polyvinyl chloride, linoleum, cork and rubber. It details suitable methods of installation and advises on the selection of the materials required for their implementation.The guidelines in this Technical Specification are intended for use in cases where manufacturer's instructions, taking account of the national code of practice in the country where the installation is to be made, are not available. References to the national codes that are currently available are listed in the Bibliography of the various parts of this Technical Specification.This Technical Specification is intended for use in conjunction with CEN/TS 14472-1 that deals with general matters relevant to textile and laminate floor coverings as well as resilient floor coverings. It gives recommendations for the installation of resilient floor coverings in new or existing buildings. It describes common procedures which are in use throughout Europe and highlights the major differences that can exist in different national procedures.Special measures beyond those described in this Technical Specification may be necessary for the successful installation of resilient floor coverings for specialist purposes such as electrostatic control or use in special wet areas. These specialist techniques are not described in this Technical Specification.
Committee |
CEN/TC 134
|
DocumentType |
Technical Specification
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Withdrawn
|
Standards | Relationship |
DIN CEN/TS 14472-4:2003-10 | Identical |
NEN NPR CEN/TS 14472-4 : 2003 | Identical |
UNI CEN/TS 14472-4 : 2003 | Identical |
S.R. CEN TS 14472-4:2003 | Identical |
UNE-CEN/TS 14472-4:2004 | Identical |
NBN CEN/TS 14472-4 : 2004 | Identical |
DS CEN/TS 14472-4 : 2003 | Identical |
EN 688:2011 | Resilient floor coverings - Specification for corklinoleum |
NFP 62 203-1 : 1993 | TRAVAUX DE BATIMENT - REVETEMENTS DE SOL PLASTIQUES COLLES - PARTIE: 1 CAHIER DES CLAUSES TECHNIQUES |
EN 548:2011 | Resilient floor coverings - Specification for plain and decorative linoleum |
EN 652:2011 | Resilient floor coverings - Polyvinyl chloride floor coverings with cork-based backing - Specification |
EN 651:2011 | Resilient floor coverings - Polyvinyl chloride floor coverings with foam layer - Specification |
EN 12199:2010 | Resilient floor coverings - Specifications for homogeneous and heterogeneous relief rubber floor coverings |
EN 686:2011 | Resilient floor coverings - Specification for plain and decorative linoleum on a foam backing |
EN 14085:2010 | Resilient floor coverings - Specification for floor panels for loose laying |
EN 653:2011 | Resilient floor coverings - Expanded (cushioned) polyvinyl chloride floor coverings - Specification |
EN 1817:2010 | Resilient floor coverings - Specification for homogeneous and heterogeneous smooth rubber floor coverings |
EN 13553:2017 | Resilient floor coverings - Polyvinyl chloride floor coverings for use in special wet areas - Specification |
EN 1816:2010 | Resilient floor coverings - Specification for homogeneous and heterogeneous smooth rubber floor coverings with foam backing |
EN 649:2011 | Resilient floor coverings - Homogenous and heterogenous polyvinyl chloride floor coverings - Specification |
EN 650:2012 | Resilient floor coverings - Polyvinyl chloride floor coverings on jute backing or on polyester felt backing or on a polyester felt with a polyvinyl chloride backing - Specification |
EN 687:2011 | Resilient floor coverings - Specification for plain and decorative linoleum on a corkment backing |
EN 654:2011 | Resilient floor coverings - Semi-flexible polyvinyl chloride tiles - Specification |
RAL RG 725/1 : 1983 | TOP SURFACE OF ELASTIC FLOOR COVERINGS; DESIGNATIONS |
EN 12103:1999 | Resilient floor coverings - Agglomerated cork underlays - Specification |
EN 12455:1999 | Resilient floor coverings - Specification for corkment underlay |
EN 655:2011 | Resilient floor coverings - Tiles of agglomerated composition cork with polyvinyl chloride wear layer - Specification |
CEN/TS 14472-1:2003 | Resilient, textile and laminate floor coverings - Design, preparation and installation - Part 1: General |
EN 12466:1998 | Resilient floor coverings - Vocabulary |
PREN 13845 : DRAFT 2015 | RESILIENT FLOOR COVERINGS - POLYVINYL CHLORIDE FLOOR COVERINGS WITH PARTICLE BASED ENHANCED SLIP RESISTANCE - SPECIFICATION |
EN 685:2007 | Resilient, textile and laminate floor coverings - Classification |
EN 12104:2000 | Resilient floor coverings - Cork floor tiles - Specification |
EN 13413:2001 | Resilient floor coverings - Polyvinyl chloride floor coverings on a filled fibrous backing - Specification |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.