CEN/TS 14972:2011
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
Fixed firefighting systems - Watermist systems - Design and installation
11-03-2023
22-06-2011
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
5 Activation and control
6 Design and installation
7 Components
8 Water supply, including additives
9 Acceptance tests and maintenance
10 Documentation
Annex A (normative) - Test protocols
Annex B (informative) - Guidelines for developing
representative fire test procedures for watermist
Annex C (informative) - Determination of drop size
distribution
Annex D (informative) - Testing of nozzles
Annex E (informative) - Function tests for acceptance
and maintenance
Annex F (normative) - Fire test procedure for certain
occupancies Ordinary hazard group OH3
Bibliography
This Technical Specification specifies requirements and gives information on design, installation and testing and gives criteria for the acceptance of fixed landbased watermist systems for specific hazards and provides fire test protocols for a variety of hazard groups.The requirements are not valid for watermist systems on ships, in aircraft, on vehicles and mobile fire appliances or for below ground systems in the mining industry.The requirements can be used as a guidance for other fixed firefighting systems, however, provided that any specific requirements for other firefighting supplies are taken into account.Aspects of watermist associated with explosion protection are beyond the scope of this document.As the fire test scenarios of this document apply to a group of similar applications, by analogy the successful performance of watermist systems also applies to that group, as defined in Annex A. Extrapolation is not covered.The document is not intended to be used as a universal design manual of watermist, as different systems have different characteristics and hence follow different design criteria to satisfy their duty requirements.In the absence of a generalized design method, it is the intent of this document that watermist systems are full-scale fire tested and its system component evaluations are conducted by qualified testing laboratories.The full system acceptance requires the relevant fire test report, the component test report(s) as well as manufacturer's design, installation, operation and maintenance manual for the application. If the gas in the system is a significant factor for extinguishment/suppression, the relevant parts of EN 12094 and EN 15004-1 are applicable.Firefighting systems in accordance with EN 12845 and water spray systems are not covered.
Committee |
CEN/TC 191
|
DocumentType |
Technical Specification
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Withdrawn
|
SupersededBy |
Standards | Relationship |
NEN NPR CEN/TS 14972 : 2011 | Identical |
DIN CEN/TS 14972;DIN SPEC 91216:2011-09 | Identical |
SIS-CEN/TS 14972:2011 | Identical |
XP CEN/TS 14972 : 2011 XP | Identical |
UNE-CEN/TS 14972:2014 | Identical |
UNI CEN/TS 14972 : 2011 | Identical |
NBN CEN/TS 14972 : 2008 | Identical |
ONORM ONR CEN/TS 14972 : 2011 | Identical |
S.R. CEN/TS 14972:2011 | Identical |
10/30216933 DC : 0 | BS EN 50553 - RAILWAY APPLICATIONS - REQUIREMENTS FOR RUNNING CAPABILITY IN CASE OF FIRE ON BOARD OF ROLLING STOCK |
I.S. EN 50600-2-5:2016 | INFORMATION TECHNOLOGY - DATA CENTRE FACILITIES AND INFRASTRUCTURES - PART 2-5: SECURITY SYSTEMS |
BS EN 50553 : 2012 | RAILWAY APPLICATIONS - REQUIREMENTS FOR RUNNING CAPABILITY IN CASE OF FIRE ON BOARD OF ROLLING STOCK |
NFPA 750 : 2015 | WATER MIST FIRE PROTECTION SYSTEMS |
EN 50600-2-5:2016 | Information technology - Data centre facilities and infrastructures - Part 2-5: Security systems |
I.S. EN 50553:2012 | RAILWAY APPLICATIONS - REQUIREMENTS FOR RUNNING CAPABILITY IN CASE OF FIRE ON BOARD OF ROLLING STOCK |
PREN 50553 : DRAFT 2010 | RAILWAY APPLICATIONS - REQUIREMENTS FOR RUNNING CAPABILITY IN CASE OF FIRE ON BOARD OF ROLLING STOCK |
ISO/IEC TS 22237-6:2018 | Information technology — Data centre facilities and infrastructures — Part 6: Security systems |
11/30203947 DC : 0 | BS 9991 - FIRE SAFETY IN THE DESIGN, MANAGEMENT AND USE OF RESIDENTIAL BUILDINGS - CODE OF PRACTICE |
CEI EN 50600-2-5 : 2017 | INFORMATION TECHNOLOGY - DATA CENTRE FACILITIES AND INFRASTRUCTURES - PART 2-5: SECURITY SYSTEMS |
14/30295814 DC : 0 | BS 8489-1 - FIXED FIRE PROTECTION SYSTEMS - INDUSTRIAL AND COMMERCIAL WATERMIST SYSTEMS - PART 1: CODE OF PRACTICE FOR DESIGN AND INSTALLATION |
09/30182748 DC : 0 | BS 5306-0 - FIRE PROTECTION INSTALLATIONS AND EQUIPMENT ON PREMISES - PART 0: GUIDE FOR THE SELECTION OF INSTALLED SYSTEMS AND OTHER FIRE EQUIPMENT |
UNI 11292 : 2008 | PREMISES INTENDED FOR THE INSTALLATION OF PUMPSET FOR FIRE FIGHTING SYSTEMS - FUNCTIONAL AND CONSTRUCTIVE REQUIREMENTS |
EN 50553 : 2012 AMD 1 2016 | RAILWAY APPLICATIONS - REQUIREMENTS FOR RUNNING CAPABILITY IN CASE OF FIRE ON BOARD OF ROLLING STOCK |
ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
ISO 5660-1:2015 | Reaction-to-fire tests Heat release, smoke production and mass loss rate Part 1: Heat release rate (cone calorimeter method) and smoke production rate (dynamic measurement) |
ISO/TR 13387-1:1999 | FIRE SAFETY ENGINEERING - PART 1: APPLICATION OF FIRE PERFORMANCE CONCEPTS TO DESIGN OBJECTIVES |
ISO 6182-9:2005 | Fire protection — Automatic sprinkler system — Part 9: Requirements and test methods for water mist nozzles |
ISO 6182-11:2003 | Fire protection Automatic sprinkler systems Part 11: Requirements and test methods for pipe hangers |
ISO 6182-12:2014 | Fire protection Automatic sprinkler systems Part 12: Requirements and test methods for grooved-end components for steel pipe systems |
ISO 565:1990 | Test sieves — Metal wire cloth, perforated metal plate and electroformed sheet — Nominal sizes of openings |
ISO/TR 13387-3:1999 | Fire safety engineering Part 3: Assessment and verification of mathematical fire models |
ISO/TR 13387-8:1999 | FIRE SAFETY ENGINEERING - PART 8: LIFE SAFETY - OCCUPANT BEHAVIOUR, LOCATION AND CONDITION |
EN ISO 14847:1999 | Rotary positive displacement pumps - Technical requirements (ISO 14847:1999) |
EN 15004-1:2008 | Fixed firefighting systems - Gas extinguishing systems - Part 1: Design, installation and maintenance (ISO 14520-1:2006, modified) |
ISO/TR 13387-7:1999 | Fire safety engineering Part 7: Detection, activation and suppression |
IEC 60335-2-37:2017 | Household and similar electrical appliances - Safety - Part 2-37: Particular requirements for commercial electric doughnut fryers and deep fat fryers |
ISO 14847:1999 | Rotary positive displacement pumps Technical requirements |
ISO/TR 13387-4:1999 | Fire safety engineering — Part 4: Initiation and development of fire and generation of fire effluents |
EN 50126-1:2017 | Railway Applications - The Specification and Demonstration of Reliability, Availability, Maintainability and Safety (RAMS) - Part 1: Generic RAMS Process |
ISO/TR 13387-2:1999 | Fire safety engineering Part 2: Design fire scenarios and design fires |
ISO 14520-1:2015 | Gaseous fire-extinguishing systems — Physical properties and system design — Part 1: General requirements |
ISO/TR 13387-6:1999 | Fire safety engineering Part 6: Structural response and fire spread beyond the enclosure of origin |
EN 60335-2-37:2002/A12:2016 | HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 2-37: PARTICULAR REQUIREMENTS FOR COMMERCIAL ELECTRIC DEEP FAT FRYERS |
ISO/TR 13387-5:1999 | Fire safety engineering Part 5: Movement of fire effluents |
1997/23/EC : 1997 | DIRECTIVE 97/23/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 29 MAY 1997 ON THE APPROXIMATION OF THE LAWS OF THE MEMBER STATES CONCERNING PRESSURE EQUIPMENT |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.