• There are no items in your cart

CEN/TS 16645:2014

Current

Current

The latest, up-to-date edition.

Ambient air - Method for the measurement of benz[a]anthracene, benzo[b]fluoranthene, benzo[j]fluoranthene, benzo[k]fluoranthene, dibenz[a,h]anthracene, indeno[1,2,3-cd]pyrene and benzo[ghi]perylene

Published date

23-04-2014

Sorry this product is not available in your region.

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviations
5 Principle of the method
6 Requirements
7 Reagents and gases
8 Apparatus
9 Sampling
10 Sample preparation
11 Analysis
12 Quantification
13 Quality control
14 Determination of measurement uncertainty
15 Interferences
Annex A (informative) - Sampling systems with
        oxidant denuder
Annex B (informative) - Extraction methods
        (examples of experimental conditions)
Annex C (informative) - Example for clean-up procedure
Annex D (informative) - Parameters for analysis (examples)
Annex E (informative) - Assessment of performance indicators
        and uncertainty contributions
Annex F (informative) - Calculation of uncertainty using
        interlaboratory comparison and field validation data
Bibliography

This Technical Specification specifies a measurement method for the determination of the particle bound polycyclic aromatic hydrocarbon (PAH) compounds benz[a]anthracene (BaA), benzo[b]fluoranthene (BbF), benzo[j]fluoranthene (BjF), benzo[k]fluoranthene (BkF), dibenz[a,h]anthracene (DBahA), indeno[1,2,3-cd]pyrene (INP) and benzo[ghi]perylene (BghiP) in ambient air, which can be used in the framework of Council Directive 2008/50/EC [10] and Directive 2004/107/EC [11]. This document specifies performance characteristics and performance criteria for this measurement method. The performance characteristics of the measurement method are based on a sampling period of 24 h.This Technical Specification describes a measurement method which comprises sampling of the selected PAH compounds as part of the PM10 particles, sample extraction and analysis by high performance liquid chromatography (HPLC) with fluorescence detector (FLD) or by gas chromatography with mass spectrometric detection (GC-MS). The method is applicable for the measurement of the PAH compounds in the concentration range from approx. 0,04 ng/m3 to approximately 20 ng/m3 for BaA, BbF, BjF, BkF, BaP, INP and BghiP and 0,02 ng/m3 to approximately 2 ng/m3 for DBahA. Table 1 shows examples for concentrations of the compounds (annual mean values) for sampling sites with different characteristics.(...)The lower limit of the applicable range depends on the noise level of the detector and the variability of the laboratory filter blank.

Committee
CEN/TC 264
DocumentType
Technical Specification
PublisherName
Comite Europeen de Normalisation
Status
Current

CEN/TR 16998:2016 Ambient air - Report on nitro- and oxy-PAHs - Origin, toxicity, concentrations and measurement methods
S.R. CEN/TR 16998:2016 AMBIENT AIR - REPORT ON NITRO- AND OXY-PAHS - ORIGIN, TOXICITY, CONCENTRATIONS AND MEASUREMENT METHODS
PD CEN/TR 16998:2016 Ambient air. Report on nitro- and oxy-PAHs. Origin, toxicity, concentrations and measurement methods

ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories
EN 13274-7:2008 Respiratory protective devices - Methods of test - Part 7: Determination of particle filter penetration
ISO 12884:2000 Ambient air Determination of total (gas and particle-phase) polycyclic aromatic hydrocarbons Collection on sorbent-backed filters with gas chromatographic/mass spectrometric analyses
EN 14625:2012 Ambient air - Standard method for the measurement of the concentration of ozone by ultraviolet photometry
EN ISO 20988:2007 Air quality - Guidelines for estimating measurement uncertainty (ISO 20988:2007)
ISO 16362:2005 Ambient air — Determination of particle-phase polycyclic aromatic hydrocarbons by high performance liquid chromatography
EN 15980:2011 Air quality - Determination of the deposition of benz[a]anthracene, benzo[b]fluoranthene, benzo[j]fluoranthene, benzo[k]fluoranthene, benzo[a]pyrene, dibenz[a,h]anthracene and indeno[1,2,3-cd]pyrene
ISO 5725-2:1994 Accuracy (trueness and precision) of measurement methods and results Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method
ENV 13005 : DRAFT 1999 GUIDE TO THE EXPRESSION OF UNCERTAINTY IN MEASUREMENT
EN 1822-1:2009 High efficiency air filters (EPA, HEPA and ULPA) - Part 1: Classification, performance testing, marking
ISO 20988:2007 Air quality Guidelines for estimating measurement uncertainty
EN 15549:2008 Air quality - Standard method for the measurement of the concentration of benzo[a]pyrene in ambient air
ISO/IEC Guide 98-3:2008 Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995)
EN 12341:2014 Ambient air - Standard gravimetric measurement method for the determination of the PM10 or PM2,5 mass concentration of suspended particulate matter

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.