• ISO 16362:2005

    Current The latest, up-to-date edition.

    Ambient air — Determination of particle-phase polycyclic aromatic hydrocarbons by high performance liquid chromatography

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Language(s):  English

    Published date:  18-02-2005

    Publisher:  International Organization for Standardization

    Add To Cart

    Abstract - (Show below) - (Hide below)

    ISO 16362:2005 specifies sampling, cleanup and analysis procedures for the quantitative determination of low volatility (particle-bound) polycyclic aromatic hydrocarbons (PAHs) in ambient air. For sampling, a low-volume or a medium/high-volume sampling device may be used. Sampling times between 1 h and 24 h are possible. The sampling volume flow rates can range from 1 m/h to 4 m/h ("low volume sampler") or from 10 m/h to about 90 m/h ("medium/high-volume sampler"). In any case, the linear face velocity at the collection filter should range between about 0,5 m/s and 0,9 m/s.

    The method has been validated for sampling periods up to 24 h. The detection limits for single PAHs and the standard deviations resulting from duplicate measurements are listed.

    ISo 16362:2005 describes a sampling and analysis procedure for PAH that involves collection from air onto a filter followed by analysis using high performance liquid chromatography usually with fluorescence detector (FLD). The use of a diode array detector (DAD) is possible. The combination of both detector types is also possible. Total suspended particulate matter is sampled.

    Generally, compounds having a boiling point above 430 °C (vapour pressure less than 10-9 kPa at 25 °C, e.g. chrysene, benz[a]anthracene) can be collected efficiently on the filter at low ambient temperatures (e.g. below 10 °C). In contrast, at higher temperatures (above 30 °C, see also ISO 12884[1]), only PAHs having boiling points above 475 °C (vapour pressure less than 10-10 kPa at 25 °C) are determined quantitatively.

    General Product Information - (Show below) - (Hide below)

    Development Note Supersedes ISO/DIS 16362 (02/2005)
    Document Type Standard
    Product Note THIS STANDARD ALSO REFERS TO NIST Special Publication 922
    Publisher International Organization for Standardization
    Status Current

    Standards Referenced By This Book - (Show below) - (Hide below)

    DIN EN 15980:2011-08 Air quality - Determination of the deposition of benz[a]anthracene, benzo[b]fluoranthene, benzo[j]fluoranthene, benzo[k]fluoranthene, benzo[a]pyrene, dibenz[a,h]anthracene and indeno[1,2,3-cd]pyrene
    UNE-EN 15980:2011 Air quality - Determination of the deposition of benz[a]anthracene, benzo[b]fluoranthene, benzo[j]fluoranthene, benzo[k]fluoranthene, benzo[a]pyrene, dibenz[a,h]anthracene and indeno[1,2,3-cd]pyrene
    06/30146327 DC : 0 EN ISO 16000-12 - INDOOR AIR - PART 12: SAMPLING STRATEGY FOR POLYCYCLIC AROMATIC HYDROCARBONS (PAHS), POLYCHLORINATED DIBENZO-P-DIOXINS (PCDDS), POLYCHLORINATED DIBENZO-FURANS (PCDFS) AND POLYCHLORINATED BIPHENYLS (PCBS)
    I.S. EN ISO 16000-12:2008 INDOOR AIR - PART 12: SAMPLING STRATEGY FOR POLYCHLORINATED BIPHENYLS (PCBS), POLYCHLORINATED DIBENZO-P-DIOXINS (PCDDS), POLYCHLORINATED DIBENZOFURANS (PCDFS) AND POLYCYCLIC AROMATIC HYDROCARBONS (PAHS)
    DIN EN 15549:2008-06 Air quality - Standard method for the measurement of the concentration of benzo[a]pyrene in ambient air
    NF EN ISO 16000-12 : 2009 INDOOR AIR - PART 12: SAMPLING STRATEGY FOR POLYCHLORINATED BIPHENYLS (PCBS), POLYCHLORINATED DIBENZO-P-DIOXINS (PCDDS), POLYCHLORINATED DIBENZOFURANS (PCDFS) AND POLYCYCLIC AROMATIC HYDROCARBONS (PAHS)
    BS EN 15549:2008 Air quality. Standard method for the measurement of the concentration of benzo(a)pyrene in ambient air
    S.R. CEN/TS 16645:2014 AMBIENT AIR - METHOD FOR THE MEASUREMENT OF BENZ[A]ANTHRACENE, BENZO[B]FLUORANTHENE, BENZO[J]FLUORANTHENE, BENZO[K]FLUORANTHENE, DIBENZ[A,H]ANTHRACENE, INDENO[1,2,3-CD]PYRENE AND BENZO[GHI]PERYLENE
    VDI 4301 Blatt 7:2017-04 (Draft) Measurement of indoor air pollution - Measurement of carboxylic acids
    VDI 4301 Blatt 5:2009-04 Measurement of indoor air pollution - Measurement of flame retardants and plasticizers based on organophosphorous compounds - Phosphoric acid ester
    VDI 4301 Blatt 6:2012-09 Measurement of indoor air pollution - Measurement of phthalates with GC/MS
    09/30193287 DC : 0 BS EN 15980 - AIR QUALITY - DETERMINATION OF THE DEPOSITION OF BENZ[A]ANTHRACENE, BENZO[B]FLUORANTHENE, BENZO[J]FLUORANTHENE, BENZO[K]FLUORANTHENE, BENZO[A]PYRENE, DIBENZ[A,H]ANTHRACENE AND INDENO[1,2,3-CD]PYRENE
    BS EN 15980:2011 Air quality. Determination of the deposition of benz[a]anthracene, benzo[b]fluoranthene, benzo[j]fluoranthene, benzo[k]fluoranthene, benzo[a]pyrene, dibenz[a,h]anthracene and indeno[1,2,3-cd]pyrene
    DIN EN ISO 16000-12:2008-08 INDOOR AIR - PART 12: SAMPLING STRATEGY FOR POLYCHLORINATED BIPHENYLS (PCBS), POLYCHLORINATED DIBENZO-P-DIOXINS (PCDDS), POLYCHLORINATED DIBENZOFURANS (PCDFS) AND POLYCYCLIC AROMATIC HYDROCARBONS (PAHS)
    UNI EN 15980 : 2011 AIR QUALITY - DETERMINATION OF THE DEPOSITION OF BENZ[A]ANTHRACENE, BENZO[B]FLUORANTHENE, BENZO[J]FLUORANTHENE, BENZO[K]FLUORANTHENE, BENZO[A]PYRENE, DIBENZ[A,H]ANTHRACENEAND INDENO[1,2,3-CD]PYRENE
    I.S. EN 15980:2011 AIR QUALITY - DETERMINATION OF THE DEPOSITION OF BENZ[A]ANTHRACENE, BENZO[B]FLUORANTHENE, BENZO[J]FLUORANTHENE, BENZO[K]FLUORANTHENE, BENZO[A]PYRENE, DIBENZ[A,H]ANTHRACENE AND INDENO[1,2,3-CD]PYRENE
    I.S. EN 15549:2008 AIR QUALITY - STANDARD METHOD FOR THE MEASUREMENT OF THE CONCENTRATION OF BENZO[A]PYRENE IN AMBIENT AIR
    UNI EN ISO 16000-12 : 2008 INDOOR AIR - PART 12: SAMPLING STRATEGY FOR POLYCHLORINATED BIPHENYLS (PCBS), POLYCHLORINATED DIBENZO-P-DIOXINS (PCDDS), POLYCHLORINATED DIBENZOFURANS (PCDFS) AND POLYCYCLIC AROMATIC HYDROCARBONS (PAHS)
    BS EN ISO 16000-12:2008 Indoor air Sampling strategy for polychlorinated biphenyls (PCBs), polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and polycyclic aromatic hydrocarbons (PAHs)
    PD CEN/TS 16645:2014 Ambient air. Method for the measurement of benz[a]anthracene, benzo[b]fluoranthene, benzo[j]fluoranthene, benzo[k]fluoranthene, dibenz[a,h]anthracene, indeno[1,2,3-cd]pyrene and benzo[ghi]perylene
    UNI EN 15549 : 2008 AIR QUALITY - STANDARD METHOD FOR THE MEASUREMENT OF THE CONCENTRATION OF BENZO[A]PYRENE IN AMBIENT AIR
    ISO 16000-12:2008 Indoor air Part 12: Sampling strategy for polychlorinated biphenyls (PCBs), polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and polycyclic aromatic hydrocarbons (PAHs)
    EN ISO 16000-12:2008 Indoor air - Part 12: Sampling strategy for polychlorinated biphenyls (PCBs), polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and polycyclic aromatic hydrocarbons (PAHs) (ISO 16000-12:2008)
    EN 15980:2011 Air quality - Determination of the deposition of benz[a]anthracene, benzo[b]fluoranthene, benzo[j]fluoranthene, benzo[k]fluoranthene, benzo[a]pyrene, dibenz[a,h]anthracene and indeno[1,2,3-cd]pyrene
    EN 15549:2008 Air quality - Standard method for the measurement of the concentration of benzo[a]pyrene in ambient air
    DIN EN 15549 E : 2008 AIR QUALITY - STANDARD METHOD FOR THE MEASUREMENT OF THE CONCENTRATION OF BENZO[A]PYRENE IN AMBIENT AIR
    UNI CEN/TS 16645 : 2014 AMBIENT AIR - METHOD FOR THE MEASUREMENT OF BENZ[A]ANTHRACENE, BENZO[B]FLUORANTHENE, BENZO[J]FLUORANTHENE, BENZO[K]FLUORANTHENE, DIBENZ[A,H]ANTHRACENE, INDENO[1,2,3-CD]PYRENE AND BENZO[GHI]PERYLENE
    CEN/TS 16645:2014 Ambient air - Method for the measurement of benz[a]anthracene, benzo[b]fluoranthene, benzo[j]fluoranthene, benzo[k]fluoranthene, dibenz[a,h]anthracene, indeno[1,2,3-cd]pyrene and benzo[ghi]perylene

    Standards Referencing This Book - (Show below) - (Hide below)

    ISO 12884:2000 Ambient air Determination of total (gas and particle-phase) polycyclic aromatic hydrocarbons Collection on sorbent-backed filters with gas chromatographic/mass spectrometric analyses
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective