CLC/TR 50484:2009
Current
The latest, up-to-date edition.
Recommendations for shielded enclosures
17-04-2009
1 Scope
2 Normative references
3 Definitions
4 General
5 Shielding
Bibliography
This Technical Report applies to shielded enclosures used for EMC testing which are to be validated according to the EN 50147 series of standards and the corresponding international standards. The object of this report is to give guidance to the selection of the shielding materials and components. The frequency range for this document is 10 kHz to 40 GHz.
Committee |
CLC/TC 210
|
DevelopmentNote |
Supersedes R210-005. (07/2010)
|
DocumentType |
Technical Report
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Supersedes |
Standards | Relationship |
PD CLC/TR 50484:2009 | Identical |
CEI CLC/TR 50484 : 2010 | Identical |
NEN NPR CLC/TR 50484 : 2009 | Identical |
EN 55016-1-4:2010/A2:2017 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-4: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - ANTENNAS AND TEST SITES FOR RADIATED DISTURBANCE MEASUREMENTS (CISPR 16-1-4:2010/A2:2017) |
CLC/TR 50485:2010 | Electromagnetic compatibility - Emission measurements in fully anechoic chambers |
UNE-EN 55016-1-4:2011 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-4: Radio disturbance and immunity measuring apparatus - Antennas and test sites for radiated disturbance measurements |
CISPR 16-1-4:2010+AMD1:2012+AMD2:2017 CSV | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-4: Radio disturbance and immunity measuring apparatus - Antennas and test sites for radiated disturbance measurements |
S.R. CLC/TR 50485:2010 | ELECTROMAGNETIC COMPATIBILITY - EMISSION MEASUREMENTS IN FULLY ANECHOIC CHAMBERS |
I.S. EN 55016-1-4:2010 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-4: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - ANTENNAS AND TEST SITES FOR RADIATED DISTURBANCE MEASUREMENTS |
BS EN 55016-1-4 : 2010 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-4: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - ANTENNAS AND TEST SITES FOR RADIATED DISTURBANCE MEASUREMENTS (CISPR 16-1-4:2010/A2:2017) |
PD CLC/TR 50485:2010 | Electromagnetic compatibility. Emission measurements in fully anechoic chambers |
CEI CLC/TR 50485 : 2013 | ELECTROMAGNETIC COMPATIBILITY - EMISSION MEASUREMENTS IN FULLY ANECHOIC CHAMBERS |
EN 50147-1:1996 | Anechoic chambers - Part 1: Shield attenuation measurement |
CISPR 22:2008 | Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement |
EN 50147-2 : 1996 | ANECHOIC CHAMBERS - PART 2: ALTERNATIVE TEST SITE SUITABILITY WITH RESPECT TO SITE ATTENUATION |
EN 55022:2010/AC:2011 | INFORMATION TECHNOLOGY EQUIPMENT - RADIO DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT (CISPR 22:2008) |
CISPR 11:2015 RLV | Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |