CLC/TS 50131-2-5:2004
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
Alarm systems - Intrusion systems - Part 2-5: Requirements for combined passive infrared and ultrasonic detectors
09-03-2023
08-04-2004
1 Scope
2 Normative references
3 Definitions and abbreviations
4 Functional requirements
4.1 Indication signal or messages
4.2 Detection
4.3 Operational requirements
4.4 Immunity of the individual technologies to
incorrect operation
4.5 Tamper security
4.6 Electrical requirements
4.7 Environmental classification and conditions
5 Marking, identification and documentation
5.1 Marking and identification
5.2 Documentation
6 Testing
6.1 General test conditions
6.2 Basic detection test
6.3 Walk testing
6.4 Verification of detection performance
6.5 Switch-on delay, time interval between signals and
indication of detection
6.6 Fault condition signals or messages: self tests
6.7 Immunity to incorrect operation
6.8 Tamper security
6.9 Electrical tests
6.10 Environmental classification and conditions
6.11 Marking and documentation
Annex A (normative) Format of standard test magnets
Annex B (normative) General test matrix
Annex C (normative) Walk test matrix
Annex D (normative) Procedure for standard target calculations
Annex E (informative) Basic detection target for the basic
test of detection capability
Annex F (informative) Calibration heat source
Annex G (normative) Calibration of the standard walk test targets
Annex H (informative) Equipment for walk test velocity control
Annex J (informative) Immunity to visible and near infrared
radiation: calibration of the light source
Annex K (informative) List of small tools suitable for testing
immunity of casing to attack
Annex L (informative) Test for resistance to reorientation of
adjustable mountings
Figures
Tables
Provides security grades 1-4 (see EN 50131-1), specific or non-specific wired or wire-free combined passive infrared and ultrasonic detectors, and is covered by environmental classes 1-3 (see EN 50130-5).
Committee |
CLC/TC 79
|
DocumentType |
Technical Specification
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Withdrawn
|
SupersededBy |
Standards | Relationship |
VDE V 0830-2-2-5 : 2005 | Identical |
XP CLC/TS 50131-2-5 : 2005 XP | Identical |
NEN NPR CLC/TS 50131-2-5 : 2004 | Identical |
DIN CLC/TS 50131-2-5 : 2005 | Identical |
UNE-CLC/TS 50131-2-5:2005 | Identical |
DD CLC/TS 50131-2-5:2004 | Identical |
CEI CLC/TS 50131-2-5 : 2005 | Identical |
UNE-CLC/TS 50131-2-5:2005 V2 | Identical |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
EN 50131-1:2006/A2:2017 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 1: SYSTEM REQUIREMENTS |
EN 50131-6:2017 | Alarm systems - Intrusion and hold-up systems - Part 6: Power supplies |
EN 50130-4:2011/A1:2014 | ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS |
IEC 60068-2-52:2017 | Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution) |
EN 50130-5:2011 | ALARM SYSTEMS - PART 5: ENVIRONMENTAL TEST METHODS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.