CLC/TS 50131-2-7-1:2009

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Alarm systems - Intrusion and hold-up systems - Part 2-7-1: Intrusion detectors - Glass break detectors (acoustic)

Published date

20-03-2009

Withdrawn date

10-03-2023

Sorry this product is not available in your region.
Summarise this standard

1 Scope
2 Normative references
3 Terms, definitions and abbreviations
  3.1 Terms and definitions
  3.2 Abbreviations
4 Functional requirements
  4.1 Event processing
  4.2 Operational requirements
  4.3 Detection
  4.4 Immunity to false alarm sources
  4.5 Tamper security
  4.6 Electrical requirements
  4.7 Environmental classification and conditions
5 Marking, identification and documentation
  5.1 Marking and/or identification
  5.2 Documentation
6 Testing
  6.1 General test conditions
  6.2 Basic detection test
  6.3 Performance tests
  6.4 Switch-on delay, time interval between signals
       and indication of detection
  6.5 Fault condition signals or messages: self tests
  6.6 Tests of immunity to false alarm sources
  6.7 Tamper security
  6.8 Electrical tests
  6.9 Environmental classification and conditions
  6.10 Marking, identification and documentation
Annex A (informative) - Example of the setup of the test
        room
Annex B (normative) - Catalogue of standard glass types
Annex C (normative) - List of small tools suitable for testing
        immunity of casing to attack
Annex D (normative) - Dimensions & requirements of a
        standard test magnet
  D.1 Normative references
  D.2 Requirements
Annex E (normative) - Immunity test: Small objects hit
        sensitivity
Annex F (normative) - Immunity test: Soft objects hit
        sensitivity
Annex G (normative) - Immunity test: Hard objects hit
        sensitivity
Annex H (normative) - General testing matrix
Annex I (normative) - Immunity test: Noise sensitivity
Annex J (normative) - Performance test setup
  J.1 Performance test setup
  J.2 Alternative performance test setup
Annex K (informative) - Manipulation test: Resistance to
        re-orientation of adjustable mountings

This Technical Specification is for passive acoustic glass break detectors installed in buildings and provides for security grades 1 to 4 (see EN 50131 1), specific or non-specific wired or wire-free detectors and uses environmental classes I to IV (see EN 50130 5). This Technical Specification does not include requirements for passive acoustic glass break detectors intended for use outdoors. A detector shall fulfil all the requirements of the specified grade. Functions additional to the mandatory functions specified in this standard may be included in the detector, providing they do not adversely influence the correct operation of the mandatory functions. This Technical Specification does not apply to system interconnections.

Committee
CLC/TC 79
DocumentType
Technical Specification
PublisherName
European Committee for Standards - Electrical
Status
Withdrawn