CLC/TS 50549-1:2015
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
Requirements for generating plants to be connected in parallel with distribution networks - Part 1: Connection to a LV distribution network above 16 A
10-03-2023
16-01-2015
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements on generating plants
5 Conformance test procedure
Annex A (informative) - Interconnection requirements
Annex B (informative) - Loss of Mains and overall
power system security
Annex C (informative) - Examples of protection strategies
Annex D (normative) - Abbreviations
Bibliography
The purpose of this Technical Specification is to provide technical guidance on the requirements for generating plants which can be operated in parallel with a distribution network.For practical reasons, this Technical Specification refers to the distribution system operator in case settings have to be defined and/or provided, even when these settings are to be defined and/or provided by another actor according to national and European legal framework. NOTE 1This includes European network codes and their national implementation, as well as further national regulations.NOTE 2Further national requirements especially for the connection to the distribution network and the operation of the generating plant can apply.The requirements of this Technical Specification apply to all generating plants, electrical machinery and electronic equipment, irrespective of the kind of primary energy source and irrespective of the presence of loads in the producer’s network that meet all of the following conditions:-converting any primary energy source into AC electricity;-connected to a LV distribution network and rated at more than 16 A per phase;-intended to operate in parallel with this distribution network under normal network operating conditions. NOTE 3Generating plants rated up to and including 16 A per phase are covered by EN 50438.NOTE 4Generating plants connected to a MV distribution network fall into the scope of CLC/TS 50549-2.Unless stated differently by the DSO generating plants connected to a medium voltage distribution network with a maximum apparent power up to 100 kVA can comply with this Technical Specification as alternative to the requirements of CLC/TS 50549-2. A different threshold may be defined by the DSO.This Technical Specification defines connection requirements.This Technical Specification recognizes the existence of National Standards, Network Codes, and specific technical requirements of the DSOs. These should be complied with. Excluded from the scope are:-the selection and evaluation of the point of connection;-power system impact assessment;-connection assessment;-island operation of generating plants, both intentional and unintentional, where no part of the distribution network is involved;-active front ends of drives feeding energy back into the distribution network for short duration;-requirements for the safety of personnel as they are already adequately covered by existing European Standards.
Committee |
CLC/TC 8X
|
DocumentType |
Technical Specification
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Withdrawn
|
SupersededBy |
Standards | Relationship |
S.R. CLC/TS 50549-1:2015 | Identical |
NEN NPR CLC/TS 50549-1 : 2015 | Identical |
DIN CLC/TS 50549-1 : 2016-07 | Identical |
VDE V 0124-549-1 : 2016-07 | Identical |
CEI CLC/TS 50549-1 : 2015 | Identical |
IEC 62933-2-1:2017 | Electrical energy storage (EES) systems - Part 2-1: Unit parameters and testing methods - General specification |
PD IEC/TS 62786:2017 | Distributed energy resources connection with the grid |
BS EN 50465:2015 | European product standard for combined heating power systems using gas fuel |
I.S. EN 50465:2015 | GAS APPLIANCES - COMBINED HEAT AND POWER APPLIANCE OF NOMINAL HEAT INPUT INFERIOR OR EQUAL TO 70 KW |
17/30354643 DC : 0 | BS EN 62933-2-1 - ELECTRIC ENERGY STORAGE (ESS) SYSTEMS - PART 2-1: UNIT PARAMETERS AND TESTING METHODS - GENERAL SPECIFICATION |
IEC TS 62786:2017 | Distributed energy resources connection with the grid |
EN IEC 62933-2-1:2018 | Electrical energy storage (EES) systems - Part 2-1: Unit parameters and testing methods - General specification |
I.S. EN IEC 62933-2-1:2018 | ELECTRICAL ENERGY STORAGE (EES) SYSTEMS - PART 2-1: UNIT PARAMETERS AND TESTING METHODS - GENERAL SPECIFICATION |
EN 50465 : 2015 | GAS APPLIANCES - COMBINED HEAT AND POWER APPLIANCE OF NOMINAL HEAT INPUT INFERIOR OR EQUAL TO 70 KW |
EN 50465:2015 | Gas appliances - Combined heat and power appliance of nominal heat input inferior or equal to 70 kW |
EN 50160 : 2010 AMD 1 2015 | VOLTAGE CHARACTERISTICS OF ELECTRICITY SUPPLIED BY PUBLIC ELECTRICITY NETWORKS |
EN 61000-4-30:2015/AC:2017-01 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-30: TESTING AND MEASUREMENT TECHNIQUES - POWER QUALITY MEASUREMENT METHODS (IEC 61000-4-30:2015/COR1:2016) |
EN 61000-6-1:2007 | Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for residential, commercial and light-industrial environments |
EN 50438:2013 | REQUIREMENTS FOR MICRO-GENERATING PLANTS TO BE CONNECTED IN PARALLEL WITH PUBLIC LOW-VOLTAGE DISTRIBUTION NETWORKS |
EN 61000-6-3:2007/A1:2011/AC:2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-3: GENERIC STANDARDS - EMISSION STANDARD FOR RESIDENTIAL, COMMERCIAL AND LIGHT-INDUSTRIAL ENVIRONMENTS (IEC 61000-6-3:2006/A1:2010) |
IEC 61000-6-2:2016 | Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments |
EN 61000-3-11:2000 | Electromagnetic compatibility (EMC) - Part 3-11: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems - Equipment with rated current |
IEC 61000-3-12:2011 | Electromagnetic compatibility (EMC) - Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16 A and ≤ 75 A per phase |
IEC TR 61000-3-15:2011 | Electromagnetic compatibility (EMC) - Part 3-15: Limits - Assessment of low frequency electromagnetic immunity and emission requirements for dispersed generation systems in LV network |
IEC 60364-1:2005 | Low-voltage electrical installations - Part 1: Fundamental principles, assessment of general characteristics, definitions |
EN 61000-2-2:2002/A1:2017 | ELECTROMAGNETIC COMPATIBILITY (EMC) - ENVIRONMENT - COMPATIBILITY LEVELS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES AND SIGNALLING IN PUBLIC LOW-VOLTAGE POWER SUPPLY SYSTEMS (IEC 61000-2-2:2002/A1:2017) |
EN 60255-127:2014 | Measuring relays and protection equipment - Part 127: Functional requirements for over/under voltage protection |
IEC 61000-6-3:2006+AMD1:2010 CSV | Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments |
HD 60364-1:2008/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 1: FUNDAMENTAL PRINCIPLES, ASSESSMENT OF GENERAL CHARACTERISTICS, DEFINITIONS |
EN 61000-6-2:2005/corrigendum:2005 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY FOR INDUSTRIAL ENVIRONMENTS (IEC 61000-6-2:2005) |
EN 61000-6-4:2007/A1:2011 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-4: GENERIC STANDARDS - EMISSION STANDARD FOR INDUSTRIAL ENVIRONMENTS |
IEC 61850-7-420:2009 | Communication networks and systems for power utility automation - Part 7-420: Basic communication structure - Distributed energy resources logical nodes |
IEC 60255-127:2010 | Measuring relays and protection equipment - Part 127: Functional requirements for over/under voltage protection |
IEC 61000-2-2:2002+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 2-2: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public low-voltage power supply systems |
IEC 61000-6-1:2016 | Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments |
IEC 61000-6-4:2006+AMD1:2010 CSV | Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments |
EN 61000-3-12:2011 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-12: LIMITS - LIMITS FOR HARMONIC CURRENTS PRODUCED BY EQUIPMENT CONNECTED TO PUBLIC LOW-VOLTAGE SYSTEMS WITH INPUT CURRENT > 16 A AND <= 75 A PER PHASE (IEC 61000-3-12:2011) |
HD 60364-5-551:2010/A11:2016 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-55: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - OTHER EQUIPMENT - CLAUSE 551: LOW-VOLTAGE GENERATING SETS |
IEC 60364-5-55:2011+AMD1:2012+AMD2:2016 CSV | Electrical installations of buildings - Part 5-55: Selection and erection of electrical equipment - Other equipment |