Preface
1 Scope
2 Reference publications
3 Definitions
4 Construction
5 Performance
6 Manufacturing and production tests
Annex A (normative) - Outline of lighting instructions for
appliances equipped with continuous pilots
Annex B (normative) - Outline of operating instructions
for appliances equipped with intermittent pilot
or interrupted pilot systems
Annex C (normative) - Recommended wire color usage
Annex D (informative) - Pertinent references to ANSI Y14.15
Annex E (informative) - Wire color designations
Annex F (informative) - Preferred graphic symbols of
commonly used items, extracted from standard
ANSI/IEEE 315, Graphic symbols for electrical
and electronics diagrams, and abbreviations for
these items
Annex G (informative) - Relationship of carbon dioxide
to oxygen in the closed room test specified in
Clause 5
Annex H (informative) - Sample failure modes and
effects analysis for component miswiring
Annex I (informative) - Legibility and design of safety
information in catalytic room heater markings
and manuals
Annex J (informative) - Table of conversion factors
This Standard applies to newly produced unvented catalytic room heaters (see Clause 3, Definitions), hereinafter referred to as heaters, constructed entirely of new, unused parts and materials, having input ratings up to and including 40,000 Btu per hour (11 723 W) for use with propane gas, except: a) heaters suitable for installation in bedrooms are to have input ratings of 10,000 Btu (2 931 W) per hour or less; and b) heaters suitable for installation in bathrooms are to have input ratings of 6,000 Btu per hour (1 758 W) or less.
DocumentType |
Standard
|
ISBN |
978-1-4883-0672-3
|
Pages |
104
|
PublisherName |
Canadian Standards Association
|
Status |
Current
|
Preface This is the fourth edition of ANSI Z21.76, Gas-fired unvented catalytic room heaters for use with propane gas. It supersedes the previous editions published in 1994, 1991, and 1988. Scope 1.1 This Standard applies to newly produced unvented catalytic room heaters (see Clause 3, Definitions), hereinafter referred to as heaters, constructed entirely of new, unused parts and materials, having input ratings up to and including 40,000 Btu per hour (11 723 W) for use with propane gas, except: a) heaters suitable for installation in bedrooms are to have input ratings of 10,000 Btu (2 931 W) per hour or less; and b) heaters suitable for installation in bathrooms are to have input ratings of 6,000 Btu per hour (1 758 W) or less. Unvented catalytic room heaters for installation in bedrooms or bathrooms are to be wall-mounted. The construction of unvented catalytic room heaters for use with propane gas is covered under Clause 4. The performance of unvented catalytic room heaters for use with propane gas is covered under Clause 5. 1.2 If a value for measurement as given in this Standard is followed by an equivalent value in other units, the first stated value is to be regarded as the specification. 1.3 All references to psi throughout this Standard are to be considered gauge pressure unless otherwise specified. 1.4 Clause 2 contains a list of standards specifically referenced in this Standard, and sources from which these reference standards may be obtained. 1.5 In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application.
CSA 6.5 : 2015 | AUTOMATIC VALVES FOR GAS APPLIANCES |
ASME B18.6.4 : 1998 | THREAD FORMING AND THREAD CUTTING TAPPING SCREWS AND METALLIC DRIVE SCREWS, INCH SERIES |
ASME B18.6.2 : 1998 | SLOTTED HEAD CAP SCREWS, SQAURE HEAD SET SCREWS, AND SLOTTED HEADLESS SET SCREWS (INCH SERIES) |
ASME PTC19.3 : 1974(R2004) | PERFORMANCE TEST CODE - PART 3: TEMPERATURE MEASUREMENT |
IEEE 315 : 1975 | GRAPHIC SYMBOLS FOR ELECTRICAL AND ELECTRONICS DIAGRAMS (INCLUDING REFERENCE DESIGNATION LETTERS) |
ASME B1.20.1 : 2013(R2018) | PIPE THREADS, GENERAL PURPOSE (INCH) |
NEMA WD 6 : 2016 | WIRING DEVICES - DIMENSIONAL SPECIFICATIONS |
ASME B36.10M : 2015 | WELDED AND SEAMLESS WROUGHT STEEL PIPE |
NFPA 70 : 2017 | NATIONAL ELECTRICAL CODE |
ANSI C101.1 : 1992 | LEAKAGE CURRENT FOR APPLIANCES |
ANSI Z223.1 : 2018 | NATIONAL FUEL GAS CODE |
ASME B18.6.3 : 2013 | MACHINE SCREWS, TAPPING SCREWS, AND METALLIC DRIVE SCREWS (INCH SERIES) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.