Preface
1 Scope
2 Reference publications
3 Definitions
4 Construction
5 Performance
6 Manufacturing and production tests
Annex A (normative) - Outline of lighting instructions
        for appliances designed for manual ignition of
        the main burner
Annex B (informative) - Pertinent references to ANSI Y14.15
Annex C (informative) - Wire color designations
Annex D (informative) - Recommended wire color usage
Annex E (informative) - Preferred graphic symbols of
        commonly used items, extracted from the
        Standard for Graphic Symbols for Electrical
        and Electronics Diagrams, ANSI/IEEE 315,
        and abbreviations for these items
Annex F (informative) - Table of conversion factors

Pertains to manually lighted, natural gas, decorative gas appliances for installation in solid-fuel burning fireplaces, hereinafter referred to as appliances, for use with natural gas only, at a maximum input rating of 90,000 Btu/hr (26376 W) (Piezo-electric ignitors), which are constructed entirely of new, unused parts and materials.

DocumentType
Standard
ISBN
978-1-4883-0690-7
Pages
0
PublisherName
Canadian Standards Association
Status
Current

Preface This is the fourth edition of ANSI Z21.84, Manually lighted, natural gas, decorative gas appliances for installation in solid-fuel burning appliances. It supersedes the previous editions published in 2012, 2002, and 1999. Scope 1.1 These requirements apply to manually lighted, natural gas, decorative gas appliances for installation in solid-fuel burning fireplaces, (see Clause 3, Definitions), hereinafter referred to as appliances, for use with natural gas only, at a maximum input rating of 90,000 Btu/hr (26 376 W) (except as noted in Clause 4.6, Piezo-electric ignitors), which are constructed entirely of new, unused parts and materials. These appliances do not incorporate a pilot burner or an automatic gas ignition system. The main burner(s) is intended to be lighted by hand each time the appliance is used. The construction of manually lighted, natural gas, decorative gas appliances for installation in solid-fuel burning fireplaces is covered under Clause 4. The performance of manually lighted, natural gas, decorative gas appliances for installation in solid-fuel burning fireplaces is covered under Clause 5. 1.2 Manually lighted, natural gas, decorative gas, appliances for installation in solid-fuel burning fireplaces are not to be thermostatically controlled. 1.3 This Standard does not cover unvented room heaters. 1.4 If a value for measurement as given in this Standard is followed by an equivalent value in other units, the first stated value is to be regarded as the specification. 1.5 All references to \"psi\" throughout this Standard are to be considered gauge pressures unless otherwise specified. 1.6 Clause 2 contains a list of standards specifically referenced in this Standard and sources from which they may be obtained. It is the responsibility of the user of this Standard to determine which referenced standard applies based on the requirements of the Authority Having Jurisdiction at the location of the installation. 1.7 In this Standard, \"shall\" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; \"should\" is used to express a recommendation or that which is advised but not required; and \"may\" is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application.

ASME PTC19.3 : 1974(R2004) PERFORMANCE TEST CODE - PART 3: TEMPERATURE MEASUREMENT
IEEE 315 : 1975 GRAPHIC SYMBOLS FOR ELECTRICAL AND ELECTRONICS DIAGRAMS (INCLUDING REFERENCE DESIGNATION LETTERS)
ASME B1.20.1 : 2013(R2018) PIPE THREADS, GENERAL PURPOSE (INCH)
NEMA WD 6 : 2016 WIRING DEVICES - DIMENSIONAL SPECIFICATIONS
ASME B36.10M : 2015 WELDED AND SEAMLESS WROUGHT STEEL PIPE
NFPA 70 : 2017 NATIONAL ELECTRICAL CODE
ANSI C101.1 : 1992 LEAKAGE CURRENT FOR APPLIANCES
NFPA 54 : 2018 NATIONAL FUEL GAS CODE
ANSI Z223.1 : 2018 NATIONAL FUEL GAS CODE

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.