CAPACITOR VOLTAGE TRANSFORMERS
01-03-2007
12-01-2013
Technical Committee on Instrument Transformers
Subcommittee on Capacitor Voltage Transformers
Preface
Reference Publications
Standard
1 Scope
2 Definitions
3 General Requirements
3.1 General
3.2 Service Conditions
3.3 Reference Publications
4 Ratings
4.1 Rated Voltage
4.2 Rated Ratio(s)
4.3 Maximum Burden Rating
4.4 Rated Burden
4.5 Rated Insulation Levels
5 Performance
5.1 Overvoltage Characteristics
5.2 Temperature Rise
5.3 Reference Range of Frequency
5.4 Accuracy Classes
5.5 Limits of Ratio Correction Factor and Phase
Angle
5.6 Short-Circuit Characteristics
5.7 Dissipation Factor of the Capacitor
5.8 Stability
6 Creepage Distances
7 Mechanical Requirements
7.1 Cantilever
7.2 Tensile
7.3 Special Requirements
8 Radio Interference
8.1 Radio Interference Voltage (RIV)
9 Carrier and Accessory Requirements
9.1 Carrier Drain Coil Insertion Loss
9.2 Carrier Drain Coil Rated Power Frequency
Voltage Drop
9.3 Carrier Drain Coil Insulation Level (BIL)
9.4 Electromagnetic Unit Carrier Frequency
Insertion Loss
9.5 Protective Gap Settings
10 Effects of Transients
10.1 Ferro-resonance
10.2 Transient Response
11 Tests-General
11.1 Classification of Tests
11.2 Nature of Tests
11.3 Standard Temperatures for Testing
11.4 Routine Tests
11.5 Type Tests
12 Routine Tests
12.1 Verification of Terminal Markings
12.2 Capacitance and Dissipation Factor Before the
Voltage Tests
12.3 Power Frequency Voltage Withstand Tests, Dry
12.4 Capacitance and Dissipation Factor After the
Voltage Tests
12.5 Accuracy Tests
12.6 Protective Gap Tests
13 Type Tests
13.1 Temperature-Rise Test
13.2 Impulse Voltage Withstand Tests
13.3 Power Frequency Voltage Withstand Test, Wet
13.4 Ferro-resonance Test
13.5 Transient Response Test
13.6 Accuracy Tests
13.7 Partial Discharge Test
13.8 High-Frequency Capacitance and Equivalent
Series Resistance
13.9 Stray Capacitance and Conductance of Low-Voltage
Terminal
13.10 Temperature Coefficient
13.11 Radio Interference Voltage Test
13.12 Accelerated Life Testing
13.13 Capacitor Loss at an Elevated Temperature
13.14 Carrier Drain Coil Tests
13.15 Electromagnetic Unit Carrier Frequency Insertion
Loss Test
13.16 Mechanical Tests
13.17 Short-Circuit Test
14 Marking
14.1 Marking of the Rating Plate of a Capacitor Voltage
Transformer
14.2 Marking of the Rating Plate for the Capacitor Units
Appendix A - Validity of Tests on Equivalent Circuits
Appendix B - High-Frequency Characteristics of Coupling
Capacitors for Power Line Carrier Circuits
Appendix C - Accelerated Life Testing
Refers to CVT (capacitor voltage transformers), comprising of a capacitor divider and an electromagnetic unit, for connection between line and ground.
DocumentType |
Standard
|
PublisherName |
Canadian Standards Association
|
Status |
Superseded
|
Supersedes |
CSA C17 : 1984 : R2004 | ALTERNATING-CURRENT ELECTRICITY METERING |
CSA C17 : 1984 : R2008 | ALTERNATING-CURRENT ELECTRICITY METERING |
CSA C17 : 1984 : R2015 | ALTERNATING-CURRENT ELECTRICITY METERING |
CSA C13 : 0 | INSTRUMENT TRANSFORMERS |
CSA C71.1 : 1999 | INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES |
NEMA 107:2016 | Methods of Measurement of Radio Influence Voltage (RIV) of High Voltage Apparatus |
ANSI C84.1 : 2016 | ELECTRIC POWER SYSTEMS AND EQUIPMENT - VOLTAGE RATINGS (60 HERTZ) |
CSA C13 : 0 | INSTRUMENT TRANSFORMERS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.