• Shopping Cart
    There are no items in your cart

CSA C22.2 NO. 60601-1-2:16 (R2021)

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Medical electrical equipment — Part 1-2: General requirements for basic safety and essential performance — Collateral Standard: Electromagnetic disturbances — Requirements and tests (IEC 60601-1-2:2014, fourth edition, 2014-02, with Canadian deviations) | Appareils électromédicaux — Partie 1-2 : Exigences générales pour la sécurité de base et les performances essentielles — Norme collatérale : Perturbations électromagnétiques — Exigences et essais (norme IEC 60601-1-2:2014 adoptée, quatrième édition, 2014-02, avec exigences propres au Canada)

Available format(s)

PDF

Language(s)

English - French

Published date

01-01-2016

Superseded date

30-05-2025

€306.67
Excluding VAT

CSA Preface This is the fourth edition of CAN/CSA-C22.2 No. 60601-1-2, Medical electrical equipment — Part 1-2: General requirements for basic safety and essential performance — Collateral Standard: Electromagnetic disturbances — Requirements and tests, which is an adoption, with Canadian deviations, of the identically titled IEC (International Electrotechnical Commission) Standard 60601-1-2 (fourth edition, 2014-02). It supersedes the previous edition, published in 2008 as CAN/CSA-C22.2 No. 60601-1-2, Medical electrical equipment — Part 1-2: General requirements for basic safety and essential performance — Collateral standard: Electromagnetic compatibility — Requirements and tests (adopted IEC 60601-1-2:2007). It is one in a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. For brevity, this Standard will be referred to as “CAN/CSA-C22.2 No. 60601-1-2” throughout. This Standard is intended to be used in conjunction with CAN/CSA-C22.2 No. 60601-1:14, Medical electrical equipment — Part 1: General requirements for basic safety and essential performance (adopted IEC 60601-1:2005, including Amendment 1:2012, with Canadian deviations). This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was reviewed for Canadian adoption by the CSA Technical Committee on Consumer and Commercial Products, under the jurisdiction of the CSA Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. Due to the medical content of this Standard, it was also approved by the CSA Technical Committee on Application of Electricity in Health Care, under the jurisdiction of the CSA Strategic Steering Committee on Health Care Technology & Systems. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope and object 1.1 * Scope This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of MEDICAL ELECTRICAL EQUIPMENT and MEDICAL ELECTRICAL SYSTEMS, hereafter referred to as ME EQUIPMENT and ME SYSTEMS. This collateral standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of ME EQUIPMENT and ME SYSTEMS in the presence of ELECTROMAGNETIC DISTURBANCES and to ELECTROMAGNETIC DISTURBANCES emitted by ME EQUIPMENT and ME SYSTEMS. BASIC SAFETY with regard to ELECTROMAGNETIC DISTURBANCES is applicable to all ME EQUIPMENT and ME SYSTEMS. 1.2 Object The object of this collateral standard is to specify general requirements and tests for BASIC SAFETY and ESSENTIAL PERFORMANCE with regard to ELECTROMAGNETIC DISTURBANCES and for ELECTROMAGNETIC EMISSIONS of ME EQUIPMENT and ME SYSTEMS. They are in addition to the requirements of the general standard and serve as the basis for particular standards. -------------------------------------------------------------------------------------------------------------------------------- Préface CSA Ce document constitue la quatrième édition de la CAN/CSA-C22.2 nº 60601-1-2, Appareils électromédicaux — Partie 1-2 : Exigences générales pour la sécurité de base et les performances essentielles — Norme collatérale : Perturbations électromagnétiques — Exigences et essais . Il s’agit de l’adoption, avec exigences propres au Canada, de la norme IEC (Commission Électrotechnique Internationale) 60601-1-2 (quatrième édition, 2014-02) qui porte le même titre. Cette norme remplace l’édition antérieure publiée en 2008 qui portait la désignation CAN/CSA-C22.2 nº 60601-1-2, Appareils électromédicaux — Partie 1-2 : Exigences générales pour la sécurité de base et les performances essentielles — Norme collatérale: Compatibilité électromagnétique — Exigences et essais (norme IEC 60601-1-2:2007 adoptée). Elle fait partie d’une série de normes publiées par le Groupe CSA qui constituent le Code canadien de l’électricité, Deuxième partie. Par souci de brièveté, tout au long de ce document, il sera appelé «CAN/CSA-C22.2 nº 60601-1-2». Cette norme est conçu pour être utilisée de concert avec la CAN/CSA-C22.2 nº 60601-1:14, Appareils électromédicaux — Partie 1 : Exigences générales pour la sécurité de base et les performances essentielles (norme IEC 60601-1:2005 adoptée, avec exigences propres au Canada, y compris l’amendement 1:2012). Cette norme est jugée convenable à l’évaluation de la conformité selon le domaine d’application établi dans la norme. Cette norme a été révisée en vue de son adoption au Canada par le Comité technique CSA sur les produits grand public et commerciaux, sous l’autorité du Comité directeur stratégique CSA sur les exigences en matière de sécurité électricité, et a été officiellement approuvée par le Comité technique. En raison de son contenu médical, la norme a également été approuvée par le Comité technique CSA sur les installations électriques dans les établissements de santé, sous l’autorité du Comité directeur stratégique CSA sur la technologie et les systèmes de soins de santé. Cette norme a été élaborée conformément aux exigences du Conseil canadien des normes concernant les Normes nationales du Canada. Cette norme a été publiée en tant que Norme nationale du Canada par Groupe CSA. Domaine d\'application et objet 1.1 * Domaine d’application La présente Norme internationale s\'applique à la SECURITE DE BASE et aux PERFORMANCES ESSENTIELLES des APPAREILS ELECTROMEDICAUX et des SYSTEMES ELECTROMEDICAUX, désignés ci-après sous le terme APPAREILS EM et SYSTEMES EM. La présente norme collatérale s\'applique à la SECURITE DE BASE et aux PERFORMANCES ESSENTIELLES des APPAREILS EM et SYSTEMES EM en présence de PERTURBATIONS ELECTROMAGNETIQUES, ainsi qu’aux PERTURBATIONS ELECTROMAGNETIQUES émises par les APPAREILS EM et SYSTEMES EM. La SECURITE DE BASE concernant les PERTURBATIONS ELECTROMAGNETIQUES est applicable à tous les APPAREILS EM et SYSTEMES EM. 1.2 Objet La présente norme collatérale a pour objet de spécifier des exigences générales et des essais applicables à la SECURITE DE BASE et aux PERFORMANCES ESSENTIELLES eu égard aux PERTURBATIONS ELECTROMAGNETIQUES et pour les EMISSIONS ELECTROMAGNETIQUES des APPAREILS EM et des SYSTEMES EM. Ils viennent en complément des exigences de la norme générale et servent de base pour les normes particulières.

DocumentType
Standard
ISBN
978-1-4883-0247-3
Pages
0
ProductNote
This standard is also refer as IEC/TR 60788:2004, IEC/TR 61000-1-1, ISO 17025, ANSI C63.7
PublisherName
Canadian Standards Association
Status
Superseded
SupersededBy

CSA Preface This is the fourth edition of CAN/CSA-C22.2 No. 60601-1-2, Medical electrical equipment — Part 1-2: General requirements for basic safety and essential performance — Collateral Standard: Electromagnetic disturbances — Requirements and tests, which is an adoption, with Canadian deviations, of the identically titled IEC (International Electrotechnical Commission) Standard 60601-1-2 (fourth edition, 2014-02). It supersedes the previous edition, published in 2008 as CAN/CSA-C22.2 No. 60601-1-2, Medical electrical equipment — Part 1-2: General requirements for basic safety and essential performance — Collateral standard: Electromagnetic compatibility — Requirements and tests (adopted IEC 60601-1-2:2007). It is one in a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. For brevity, this Standard will be referred to as “CAN/CSA-C22.2 No. 60601-1-2” throughout. This Standard is intended to be used in conjunction with CAN/CSA-C22.2 No. 60601-1:14, Medical electrical equipment — Part 1: General requirements for basic safety and essential performance (adopted IEC 60601-1:2005, including Amendment 1:2012, with Canadian deviations). This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was reviewed for Canadian adoption by the CSA Technical Committee on Consumer and Commercial Products, under the jurisdiction of the CSA Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. Due to the medical content of this Standard, it was also approved by the CSA Technical Committee on Application of Electricity in Health Care, under the jurisdiction of the CSA Strategic Steering Committee on Health Care Technology & Systems. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope and object 1.1 * Scope This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of MEDICAL ELECTRICAL EQUIPMENT and MEDICAL ELECTRICAL SYSTEMS, hereafter referred to as ME EQUIPMENT and ME SYSTEMS. This collateral standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of ME EQUIPMENT and ME SYSTEMS in the presence of ELECTROMAGNETIC DISTURBANCES and to ELECTROMAGNETIC DISTURBANCES emitted by ME EQUIPMENT and ME SYSTEMS. BASIC SAFETY with regard to ELECTROMAGNETIC DISTURBANCES is applicable to all ME EQUIPMENT and ME SYSTEMS. 1.2 Object The object of this collateral standard is to specify general requirements and tests for BASIC SAFETY and ESSENTIAL PERFORMANCE with regard to ELECTROMAGNETIC DISTURBANCES and for ELECTROMAGNETIC EMISSIONS of ME EQUIPMENT and ME SYSTEMS. They are in addition to the requirements of the general standard and serve as the basis for particular standards. -------------------------------------------------------------------------------------------------------------------------------- Préface CSA Ce document constitue la quatrième édition de la CAN/CSA-C22.2 nº 60601-1-2, Appareils électromédicaux — Partie 1-2 : Exigences générales pour la sécurité de base et les performances essentielles — Norme collatérale : Perturbations électromagnétiques — Exigences et essais . Il s’agit de l’adoption, avec exigences propres au Canada, de la norme IEC (Commission Électrotechnique Internationale) 60601-1-2 (quatrième édition, 2014-02) qui porte le même titre. Cette norme remplace l’édition antérieure publiée en 2008 qui portait la désignation CAN/CSA-C22.2 nº 60601-1-2, Appareils électromédicaux — Partie 1-2 : Exigences générales pour la sécurité de base et les performances essentielles — Norme collatérale: Compatibilité électromagnétique — Exigences et essais (norme IEC 60601-1-2:2007 adoptée). Elle fait partie d’une série de normes publiées par le Groupe CSA qui constituent le Code canadien de l’électricité, Deuxième partie. Par souci de brièveté, tout au long de ce document, il sera appelé «CAN/CSA-C22.2 nº 60601-1-2». Cette norme est conçu pour être utilisée de concert avec la CAN/CSA-C22.2 nº 60601-1:14, Appareils électromédicaux — Partie 1 : Exigences générales pour la sécurité de base et les performances essentielles (norme IEC 60601-1:2005 adoptée, avec exigences propres au Canada, y compris l’amendement 1:2012). Cette norme est jugée convenable à l’évaluation de la conformité selon le domaine d’application établi dans la norme. Cette norme a été révisée en vue de son adoption au Canada par le Comité technique CSA sur les produits grand public et commerciaux, sous l’autorité du Comité directeur stratégique CSA sur les exigences en matière de sécurité électricité, et a été officiellement approuvée par le Comité technique. En raison de son contenu médical, la norme a également été approuvée par le Comité technique CSA sur les installations électriques dans les établissements de santé, sous l’autorité du Comité directeur stratégique CSA sur la technologie et les systèmes de soins de santé. Cette norme a été élaborée conformément aux exigences du Conseil canadien des normes concernant les Normes nationales du Canada. Cette norme a été publiée en tant que Norme nationale du Canada par Groupe CSA. Domaine d\'application et objet 1.1 * Domaine d’application La présente Norme internationale s\'applique à la SECURITE DE BASE et aux PERFORMANCES ESSENTIELLES des APPAREILS ELECTROMEDICAUX et des SYSTEMES ELECTROMEDICAUX, désignés ci-après sous le terme APPAREILS EM et SYSTEMES EM. La présente norme collatérale s\'applique à la SECURITE DE BASE et aux PERFORMANCES ESSENTIELLES des APPAREILS EM et SYSTEMES EM en présence de PERTURBATIONS ELECTROMAGNETIQUES, ainsi qu’aux PERTURBATIONS ELECTROMAGNETIQUES émises par les APPAREILS EM et SYSTEMES EM. La SECURITE DE BASE concernant les PERTURBATIONS ELECTROMAGNETIQUES est applicable à tous les APPAREILS EM et SYSTEMES EM. 1.2 Objet La présente norme collatérale a pour objet de spécifier des exigences générales et des essais applicables à la SECURITE DE BASE et aux PERFORMANCES ESSENTIELLES eu égard aux PERTURBATIONS ELECTROMAGNETIQUES et pour les EMISSIONS ELECTROMAGNETIQUES des APPAREILS EM et des SYSTEMES EM. Ils viennent en complément des exigences de la norme générale et servent de base pour les normes particulières.

IEC 61000-6-2:2016 Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
IEEE/ANSI C63.4-2014 REDLINE American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
IEC TR 61000-2-5:2017 Electromagnetic compatibility (EMC) - Part 2-5: Environment - Description and classification of electromagnetic environments
ISO 11451-3:2007 Road vehicles — Vehicle test methods for electrical disturbances from narrowband radiated electromagnetic energy — Part 3: On-board transmitter simulation
ISO/TR 16142:2006 Medical devices — Guidance on the selection of standards in support of recognized essential principles of safety and performance of medical devices
ISO 14708-3:2017 Implants for surgery — Active implantable medical devices — Part 3: Implantable neurostimulators
IEC 60601-2-27:2011 Medical electrical equipment - Part 2-27: Particular requirements for the basic safety and essential performance of electrocardiographic monitoring equipment
CISPR 16-2-3:2016 Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements
IEC 61000-6-1:2016 Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
ISO 11452-9:2012 Road vehicles — Component test methods for electrical disturbances from narrowband radiated electromagnetic energy — Part 9: Portable transmitters
ISO 11452-8:2015 Road vehicles — Component test methods for electrical disturbances from narrowband radiated electromagnetic energy — Part 8: Immunity to magnetic fields
IEC 61496-1:2004 Safety of machinery - Electro-sensitive protective equipment - Part 1: General requirements and tests
IEC 60601-2-44:2009+AMD1:2012+AMD2:2016 CSV Medical electrical equipment - Part 2-44: Particular requirements for the basic safety and essential performance of X-ray equipment for computed tomography

Access your standards online with a subscription

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

€306.67
Excluding VAT