CSA C22.2 No. 80601-2-30 : 2010 : INC : COR 1 : 2011
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
MEDICAL ELECTRICAL EQUIPMENT - PART 2-30: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF AUTOMATED NON-INVASIVE SPHYGMOMANOMETERS
Hardcopy , PDF
28-07-2021
English
01-01-2015
FOREWORD
INTRODUCTION
201.1 Scope, object and related standards
201.2 Normative references
201.3 Terms and definitions
201.4 General requirements
201.5 General requirements for testing ME EQUIPMENT
201.6 Classification of ME EQUIPMENT and ME SYSTEMS
201.7 ME EQUIPMENT identification, marking and documents
201.8 Protection against electrical HAZARDS from ME EQUIPMENT
201.9 Protection against MECHANICAL HAZARDS of ME EQUIPMENT
and ME SYSTEMS
201.10 Protection against unwanted and excessive radiation
HAZARDS
201.11 Protection against excessive temperatures and other
HAZARDS
201.12 Accuracy of controls and instruments and protection
against hazardous outputs
201.13 HAZARDOUS SITUATIONS and fault conditions
201.14 PROGRAMMABLE ELECTRICAL MEDICAL SYSTEMS (PEMS)
201.15 Construction of ME EQUIPMENT
201.16 ME SYSTEMS
201.17 Electromagnetic compatibility of ME EQUIPMENT and
ME SYSTEMS
201.101 Requirements for CUFFS
201.102 Connection tubing and CUFF connectors
201.103 Unauthorized access
201.104 Maximum inflating time
201.105 Automatic cycling modes
201.106 Clinical accuracy
202 Electromagnetic compatibility - Requirements and tests
Annexes
Annex C (informative) - Guide to marking and labelling
requirements for ME EQUIPMENT and ME SYSTEMS
Annex AA (informative) - Particular guidance and rationale
Annex BB (informative) - Environmental aspects
Annex CC (informative) - Reference to the essential principles
Bibliography
Index of defined terms
Pertains to the BASIC SAFETY and ESSENTIAL PERFORMANCE of AUTOMATED SPHYGMOMANOMETERS, hereafter referred to as ME EQUIPMENT, which by means of an inflatable CUFF, are used for intermittent indirect measurement of the BLOOD PRESSURE without arterial puncture.
DevelopmentNote |
Amendment 1 is available separately, see CSA C22.2.80601-2-30A. (10/2015)
|
DocumentType |
Standard
|
Pages |
140
|
ProductNote |
Reconfirmed EN
|
PublisherName |
Canadian Standards Association
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
ISO 81060-1:2007 | Non-invasive sphygmomanometers — Part 1: Requirements and test methods for non-automated measurement type |
IEC 60068-2-31:2008 | Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens |
IEC 60068-2-64:2008 | Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance |
ISO 21647:2004 | Medical electrical equipment Particular requirements for the basic safety and essential performance of respiratory gas monitors |
IEC 60601-1-2:2014 | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
IEC 60601-2-2:2017 | Medical electrical equipment - Part 2-2: Particular requirements for the basic safety and essential performance of high frequency surgical equipment and high frequency surgical accessories |
CR 13825:2000 | Luer connectors - A report to CEN chef from the CEN forum task group "Luer fittings" |
ISO/TR 16142:2006 | Medical devices Guidance on the selection of standards in support of recognized essential principles of safety and performance of medical devices |
ISO 81060-2:2013 | Non-invasive sphygmomanometers Part 2: Clinical investigation of automated measurement type |
ISO 9919:2005 | Medical electrical equipment Particular requirements for the basic safety and essential performance of pulse oximeter equipment for medical use |
ISO 594-2:1998 | Conical fittings with 6 % (Luer) taper for syringes, needles and certain other medical equipment Part 2: Lock fittings |
ISO 594-1:1986 | Conical fittings with a 6 % (Luer) taper for syringes, needles and certain other medical equipment Part 1: General requirements |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.