• Shopping Cart
    There are no items in your cart

CSA C68.5 : 2013

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

View Superseded by

SHIELDED AND CONCENTRIC NEUTRAL POWER CABLE FOR DISTRIBUTION UTILITIES

Available format(s)

Hardcopy , PDF

Withdrawn date

06-03-2020

Superseded by

CSA C68.5:20

Language(s)

English, French

Published date

01-01-2013

Preface
1 Scope
2 Reference publications
3 Definitions and abbreviations
4 Conductors
5 Conductor shield (stress control layer)
6 Insulation
7 Extruded insulation shield
8 Concentric neutral and other metallic shielding
9 Jacket
10 Cable assembly and identification
11 Production tests
12 Qualification tests
13 Information to be supplied by purchaser
Annex A (informative) - Operating limits
Annex B (informative) - Calculated insulation diameters for
        common sizes based on AEIC CS8-00
Annex C (normative) - Calculated insulation diameters for
        common sizes based on ICEA Standards
Annex D (informative) - Shielding
Annex E (informative) - Handling and installation parameters
Annex F (informative) - Ethylene alkene copolymer (EAM)
Annex G (normative) - Insulation compound inspection
Annex H (informative) - Typical concentric neutral copper
        conductor
Annex I (informative) - Connectability test for blocked
        strand conductor
Annex J (informative) - Concentric neutral cables rated
        less than 15 kV

Pertains to materials, constructions, and testing of tree-retardant cross-linked polyethylene and ethylene propylene rubber-insulated single conductor or triplexed primary shielded and concentric neutral power cables rated 15 to 46 kV that are used for the transmission and distribution of electrical energy.

DevelopmentNote
Together with CSA C68.10, it supersedes CSA C68.3. (04/2008) French Edition issued on 01-07-2013. (09/2013)
DocumentType
Standard
Pages
122
PublisherName
Canadian Standards Association
Status
Withdrawn
SupersededBy
Supersedes

CSA C22.2 No. 131 : 2014 TYPE TECK 90 CABLE
IEEE 1242-1999 IEEE Guide for Specifying and Selecting Power, Control, and Special-Purpose Cable for Petroleum and Chemical Plants
CSA C22.2 No. 327 : 2016 HDPE CONDUIT, CONDUCTORS-IN-CONDUIT, AND FITTINGS
CSA C22.2 No. 273 : 2014(R2019) CABLEBUS
C22.1-15 PACKAGE Consists of C22.1-15, Canadian electrical code, part I (23rd edition), safety standard for electrical installations; C22.1HB-15, Canadian electrical code handbook - an explanation of rules of the Canadian electrical code, part I and the 2015 Electrical quick reference
C22.1HB-18 Canadian Electrical Code Handbook - An Explanation of the Rules of the Canadian Electrical Code, Part I
IEEE 532-2007 REDLINE IEEE Guide for Selecting and Testing Jackets for Power, Instrumentation, and Control Cables
CSA C68.10 : 2014 SHIELDED POWER CABLE FOR COMMERCIAL AND INDUSTRIAL APPLICATIONS, 5-46 KV

ICEA T 32 645 : 1993 TEST METHOD FOR ESTABLISHING VOLUME RESISTIVITY COMPATIBILITY OF WATER BLOCKING COMPONENTS WITH EXTRUDED SEMICONDUCTING SHIELD MATERIALS
ASTM D 4496 : 2013 Standard Test Method for D-C Resistance or Conductance of Moderately Conductive Materials
IEEE 532-2007 REDLINE IEEE Guide for Selecting and Testing Jackets for Power, Instrumentation, and Control Cables
NEMA WC 53 : 2016 STANDARD TEST METHODS FOR EXTRUDED DIELECTRIC POWER, CONTROL, INSTRUMENTATION, AND PORTABLE CABLES FOR TEST
ICEA T 31 610 : 2014 TEST METHOD FOR CONDUCTING LONGITUDINAL WATER PENETRATION RESISTANCE TESTS ON BLOCKED CONDUCTORS
ASTM B 29 : 2014 : REDLINE Standard Specification for Refined Lead
IEEE 82 : 2002 TEST PROCEDURE FOR IMPULSE VOLTAGE TESTS ON INSULATED CONDUCTORS
ICEA P 32 382 : 2007(R2018) SHORT CIRCUIT CHARACTERISTICS OF INSULATED CABLES
ICEA T 34 664 : 2014 TEST METHOD FOR CONDUCTING LONGITUDINAL WATER PENETRATION RESISTANCE TESTS ON LONGITUDINAL WATER BLOCKED CABLES
ASTM B 231/B231M : 2016 : REDLINE Standard Specification for Concentric-Lay-Stranded Aluminum 1350 Conductors
ICEA S 94 649 : 2013 CONCENTRIC NEUTRAL CABLES RATED 5 THROUGH 46 KV
ASTM B 496 : 2016 : REDLINE Standard Specification for Compact Round Concentric-Lay-Stranded Copper Conductors
ASTM D 2765 : 2016 : REDLINE Standard Test Methods for Determination of Gel Content and Swell Ratio of Crosslinked Ethylene Plastics
ICEA T 27 581 : 2016 STANDARD TEST METHODS FOR EXTRUDED DIELECTRIC POWER, CONTROL, INSTRUMENTATION, AND PORTABLE CABLES FOR TEST
CSA ISO 9001 : 2016 QUALITY MANAGEMENT SYSTEMS - REQUIREMENTS
ASTM B 5 : 2016 : REDLINE Standard Specification for High Conductivity Tough-Pitch Copper Refinery Shapes
NEMA WC 26/EEMAC 201:2008 Binational Wire and Cable Packaging Standard
ICEA S 97 682 : 2013 UTILITY SHIELDED POWER CABLES RATED 5 THROUGH 46 KV
CSA C22.2 No. 2556 : 2015 WIRE AND CABLE TEST METHODS
ICEA T 28 562 : 2003(R2014) TEST METHOD FOR MEASUREMENT OF HOT CREEP OF POLYMERIC INSULATIONS
ICEA T 25 425 : 1981 GUIDE FOR ESTABLISHING STABILITY OF VOLUME RESISTIVITY FOR SEMICONDUCTING POLYMERIC COMPONENTS OF POWER CABLES
ASTM B 835 : 2014 : REDLINE Standard Specification for Compact Round Stranded Copper Conductors Using Single Input Wire Construction
ASTM D 471 : 2016-02 TEST METHOD FOR RUBBER PROPERTY - EFFECT OF LIQUIDS
ICEA T 24 380 : 2013 PARTIAL DISCHARGE TEST PROCEDURE
ASTM D 746 : 2014 : REDLINE Standard Test Method for Brittleness Temperature of Plastics and Elastomers by Impact
ASTM D 1693 : 2015 : REDLINE Standard Test Method for Environmental Stress-Cracking of Ethylene Plastics

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.