CSA C68.5 : 2013
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
SHIELDED AND CONCENTRIC NEUTRAL POWER CABLE FOR DISTRIBUTION UTILITIES
Hardcopy , PDF
06-03-2020
English, French
01-01-2013
Preface
1 Scope
2 Reference publications
3 Definitions and abbreviations
4 Conductors
5 Conductor shield (stress control layer)
6 Insulation
7 Extruded insulation shield
8 Concentric neutral and other metallic shielding
9 Jacket
10 Cable assembly and identification
11 Production tests
12 Qualification tests
13 Information to be supplied by purchaser
Annex A (informative) - Operating limits
Annex B (informative) - Calculated insulation diameters for
common sizes based on AEIC CS8-00
Annex C (normative) - Calculated insulation diameters for
common sizes based on ICEA Standards
Annex D (informative) - Shielding
Annex E (informative) - Handling and installation parameters
Annex F (informative) - Ethylene alkene copolymer (EAM)
Annex G (normative) - Insulation compound inspection
Annex H (informative) - Typical concentric neutral copper
conductor
Annex I (informative) - Connectability test for blocked
strand conductor
Annex J (informative) - Concentric neutral cables rated
less than 15 kV
Pertains to materials, constructions, and testing of tree-retardant cross-linked polyethylene and ethylene propylene rubber-insulated single conductor or triplexed primary shielded and concentric neutral power cables rated 15 to 46 kV that are used for the transmission and distribution of electrical energy.
DevelopmentNote |
Together with CSA C68.10, it supersedes CSA C68.3. (04/2008) French Edition issued on 01-07-2013. (09/2013)
|
DocumentType |
Standard
|
Pages |
122
|
PublisherName |
Canadian Standards Association
|
Status |
Withdrawn
|
SupersededBy | |
Supersedes |
CSA C22.2 No. 131 : 2014 | TYPE TECK 90 CABLE |
IEEE 1242-1999 | IEEE Guide for Specifying and Selecting Power, Control, and Special-Purpose Cable for Petroleum and Chemical Plants |
CSA C22.2 No. 327 : 2016 | HDPE CONDUIT, CONDUCTORS-IN-CONDUIT, AND FITTINGS |
CSA C22.2 No. 273 : 2014(R2019) | CABLEBUS |
C22.1-15 PACKAGE | Consists of C22.1-15, Canadian electrical code, part I (23rd edition), safety standard for electrical installations; C22.1HB-15, Canadian electrical code handbook - an explanation of rules of the Canadian electrical code, part I and the 2015 Electrical quick reference |
C22.1HB-18 | Canadian Electrical Code Handbook - An Explanation of the Rules of the Canadian Electrical Code, Part I |
IEEE 532-2007 REDLINE | IEEE Guide for Selecting and Testing Jackets for Power, Instrumentation, and Control Cables |
CSA C68.10 : 2014 | SHIELDED POWER CABLE FOR COMMERCIAL AND INDUSTRIAL APPLICATIONS, 5-46 KV |
ICEA T 32 645 : 1993 | TEST METHOD FOR ESTABLISHING VOLUME RESISTIVITY COMPATIBILITY OF WATER BLOCKING COMPONENTS WITH EXTRUDED SEMICONDUCTING SHIELD MATERIALS |
ASTM D 4496 : 2013 | Standard Test Method for D-C Resistance or Conductance of Moderately Conductive Materials |
IEEE 532-2007 REDLINE | IEEE Guide for Selecting and Testing Jackets for Power, Instrumentation, and Control Cables |
NEMA WC 53 : 2016 | STANDARD TEST METHODS FOR EXTRUDED DIELECTRIC POWER, CONTROL, INSTRUMENTATION, AND PORTABLE CABLES FOR TEST |
ICEA T 31 610 : 2014 | TEST METHOD FOR CONDUCTING LONGITUDINAL WATER PENETRATION RESISTANCE TESTS ON BLOCKED CONDUCTORS |
ASTM B 29 : 2014 : REDLINE | Standard Specification for Refined Lead |
IEEE 82 : 2002 | TEST PROCEDURE FOR IMPULSE VOLTAGE TESTS ON INSULATED CONDUCTORS |
ICEA P 32 382 : 2007(R2018) | SHORT CIRCUIT CHARACTERISTICS OF INSULATED CABLES |
ICEA T 34 664 : 2014 | TEST METHOD FOR CONDUCTING LONGITUDINAL WATER PENETRATION RESISTANCE TESTS ON LONGITUDINAL WATER BLOCKED CABLES |
ASTM B 231/B231M : 2016 : REDLINE | Standard Specification for Concentric-Lay-Stranded Aluminum 1350 Conductors |
ICEA S 94 649 : 2013 | CONCENTRIC NEUTRAL CABLES RATED 5 THROUGH 46 KV |
ASTM B 496 : 2016 : REDLINE | Standard Specification for Compact Round Concentric-Lay-Stranded Copper Conductors |
ASTM D 2765 : 2016 : REDLINE | Standard Test Methods for Determination of Gel Content and Swell Ratio of Crosslinked Ethylene Plastics |
ICEA T 27 581 : 2016 | STANDARD TEST METHODS FOR EXTRUDED DIELECTRIC POWER, CONTROL, INSTRUMENTATION, AND PORTABLE CABLES FOR TEST |
CSA ISO 9001 : 2016 | QUALITY MANAGEMENT SYSTEMS - REQUIREMENTS |
ASTM B 5 : 2016 : REDLINE | Standard Specification for High Conductivity Tough-Pitch Copper Refinery Shapes |
NEMA WC 26/EEMAC 201:2008 | Binational Wire and Cable Packaging Standard |
ICEA S 97 682 : 2013 | UTILITY SHIELDED POWER CABLES RATED 5 THROUGH 46 KV |
CSA C22.2 No. 2556 : 2015 | WIRE AND CABLE TEST METHODS |
ICEA T 28 562 : 2003(R2014) | TEST METHOD FOR MEASUREMENT OF HOT CREEP OF POLYMERIC INSULATIONS |
ICEA T 25 425 : 1981 | GUIDE FOR ESTABLISHING STABILITY OF VOLUME RESISTIVITY FOR SEMICONDUCTING POLYMERIC COMPONENTS OF POWER CABLES |
ASTM B 835 : 2014 : REDLINE | Standard Specification for Compact Round Stranded Copper Conductors Using Single Input Wire Construction |
ASTM D 471 : 2016-02 | TEST METHOD FOR RUBBER PROPERTY - EFFECT OF LIQUIDS |
ICEA T 24 380 : 2013 | PARTIAL DISCHARGE TEST PROCEDURE |
ASTM D 746 : 2014 : REDLINE | Standard Test Method for Brittleness Temperature of Plastics and Elastomers by Impact |
ASTM D 1693 : 2015 : REDLINE | Standard Test Method for Environmental Stress-Cracking of Ethylene Plastics |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.