AUTOMATIC ELECTRICAL CONTROLS FOR HOUSEHOLD AND SIMILAR USE - PART 1: GENERAL REQUIREMENTS
09-08-2021
12-01-2013
Foreword
1. Scope and normative references
2. Definitions
3. General requirements
4. General notes on tests
5. Rating
6. Classification
7. Information
8. Protection against electric shock
9. Provision for protective earthing
10. Terminals and terminations (under consideration)
11. Constructional requirements
12. Moisture and dust resistance
13. Electric strength and insulation resistance
14. Heating
15. Manufacturing deviation and drift
16. Environmental stress
17. Endurance
18. Mechanical strength
19. Threaded parts and connections
20. Creepage distances, clearances and distances
through insulation
21. Resistance to heat, fire and tracking
22. Resistance to corrosion
23. Radio interference suppression
24. Components
25. Normal operation
26. Operation with mains-borne perturbations, magnetic
and electromagnetic
27. Abnormal operation
28. Guidance on the use of electronic disconnection
Annexes
A Indelibility of markings
B Measurement of creepage distances and clearances
in air
C Cotton used for mercury switch test
D Heat, fire and tracking
E Circuit for measuring leakage current
F Heat and fire resistance categories
G Heat and fire resistance tests
H Requirements for electronic controls
J Requirements for controls using thermistors
This standard applies to automatic electrical controls for use in, on, or in association with equipment for household and similar use. This Standard applies to the safety of such equipment designed to be installed and used in accordance with the rules of the Canadian Electrical Code. It also applies to the inherent safety. Canadian Deviations are included in this Standard.
DocumentType |
Standard
|
PublisherName |
Canadian Standards Association
|
Status |
Withdrawn
|
SupersededBy |
Standards | Relationship |
IEC 60730-1:2013+AMD1:2015 CSV | Similar to |
IEC 60112:2003+AMD1:2009 CSV | Method for the determination of the proof and the comparative tracking indices of solid insulating materials |
IEC 60738-1:2006+AMD1:2009 CSV | Thermistors - Directly heated positive temperature coefficient -Part 1: Generic specification |
IEC 60212:2010 | Standard conditions for use prior to and during the testing of solid electrical insulating materials |
IEC 60127:1974 | Cartridge fuse-links for miniature fuses |
IEC 60384-14:2013+AMD1:2016 CSV | Fixed capacitors for use in electronic equipment - Part 14: Sectional specification - Fixed capacitors for electromagnetic interference suppression and connection to the supply mains |
IEC 60695-2-1:1991 | Fire hazard testing - Part 2: Test methods - Section 1: Glow-wire test and guidance |
CSA C22.2 No. 49 : 2014 | FLEXIBLE CORDS AND CABLES |
CSA C22.2 No. 0.4 : 2004(R2013) | BONDING OF ELECTRICAL EQUIPMENT |
CSA C22.2 No. 21 : 2014 | CORD SETS AND POWER-SUPPLY CORDS |
IEC 60085:2007 | Electrical insulation - Thermal evaluation and designation |
IEC 60129:1984 | Alternating current disconnectors and earthing switches |
IEC 60998-2-2:2002 | Connecting devices for low-voltage circuits for household and similar purposes - Part 2-2: Particular requirements for connecting devices as separate entities with screwless-type clamping units |
IEC 60707:1999 | Flammability of solid non-metallic materials when exposed to flame sources - List of test methods |
IEC 60906-2:2011 | IEC system of plugs and socket-outlets for household and similar purposes - Part 2: Plugs and socket-outlets 15 A 125 V a.c. and 20 A 125 V a.c. |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 61058-1:2016 | Switches for appliances - Part 1: General requirements |
IEC 60738-1-1:2008 | Thermistors - Directly heated positive step-function temperature coefficient - Part 1-1: Blank detail specification - Current limiting application - Assessment level EZ |
IEC 60423:2007 | Conduit systems for cable management - Outside diameters of conduits for electrical installations and threads for conduits and fittings |
IEC 60801-3:1984 | Electromagnetic compatibility for industrial-process measurement and control equipment - Part 3: Radiated electromagnetic field requirements |
IEC 60216-1:2013 | Electrical insulating materials - Thermal endurance properties - Part 1: Ageing procedures and evaluation of test results |
IEC 60801-2:1991 | Electromagnetic compatibility for industrial-process measurement and control equipment - Part 2: Electrostatic discharge requirements |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.