CSA IEC 61400-24 : 2012 : R2017
Current
The latest, up-to-date edition.
WIND TURBINES - PART 24: LIGHTNING PROTECTION
Hardcopy , PDF
English
01-01-2017
FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and units
5 Abbreviations
6 Lightning environment for wind turbine
7 Lightning exposure assessment
8 Lightning protection of subcomponents
9 Earthing of wind turbines and wind farms
10 Personal safety
11 Documentation of lightning protection system
12 Inspection of lightning protection system
Annex A (informative) - The lightning phenomenon in
relation to wind turbines
Annex B (informative) - Lightning exposure assessment
Annex C (informative) - Protection methods for blades
Annex D (informative) - Test specifications
Annex E (informative) - Application of lightning protection
zones (LPZ) concept at a wind turbine
Annex F (informative) - Selection and installation of a
coordinated SPD protection in wind turbines
Annex G (informative) - Additional information on bonding
and shielding and installation technique
Annex H (informative) - Testing methods for system level
immunity tests
Annex I (informative) - Earth termination system
Annex J (informative) - Example of defined measuring
points
Annex K (informative) - Typical lightning damage questionnaire
Annex L (informative) - Monitoring systems
Annex M (informative) - Guidelines for small wind turbines -
Microgeneration
Bibliography
Pertains to lightning protection of wind turbine generators and wind power systems.
DevelopmentNote |
Supersedes CSA C61400-24. (12/2012)
|
DocumentType |
Standard
|
ISBN |
978-1-77139-014-9
|
Pages |
170
|
ProductNote |
Reconfirmed EN
|
PublisherName |
Canadian Standards Association
|
Status |
Current
|
Standards | Relationship |
IEC 61400-24:2010 | Identical |
IEC 60243-1:2013 | Electric strength of insulating materials - Test methods - Part 1: Tests at power frequencies |
IEC TS 60479-1:2005+AMD1:2016 CSV | Effects of current on human beings and livestock - Part 1: Generalaspects |
IEC 62153-4-3:2013 | Metallic communication cable test methods - Part 4-3: Electromagnetic compatibility (EMC) - Surface transfer impedance - Triaxial method |
IEC 60099-4:2014 | Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems |
IEC 61643-12:2008 | Low-voltage surge protective devices - Part 12: Surge protective devices connected to low-voltage power distribution systems - Selection and application principles |
IEC 60204-1:2016 | Safety of machinery - Electrical equipment of machines - Part 1: General requirements |
IEC 60364-5-53:2001+AMD1:2002+AMD2:2015 CSV | Electrical installations of buildings - Part 5-53: Selection and erection of electrical equipment - Isolation, switching and control |
IEC TS 61400-23:2001 | Wind turbine generator systems - Part 23: Full-scale structural testing of rotor blades |
IEC 60204-11:2000 | Safety of machinery - Electrical equipment of machines - Part 11: Requirements for HV equipment for voltages above 1 000 V a.c. or 1 500 V d.c. and not exceeding 36 kV |
HD 637 S1:1999/corrigendum:2005 | POWER INSTALLATIONS EXCEEDING 1 KV A.C. |
IEC TR 61000-5-2:1997 | Electromagnetic compatibility (EMC) - Part 5: Installation and mitigation guidelines - Section 2: Earthing and cabling |
IEC 61643-21:2000+AMD1:2008+AMD2:2012 CSV | Low voltage surge protective devices - Part 21: Surge protective devices connected to telecommunications and signalling networks - Performance requirements and testing methods |
IEC 60243-3:2013 | Electric strength of insulating materials - Test methods - Part 3: Additional requirements for 1,2/50 µs impulse tests |
IEC 62305-1:2010 | Protection against lightning - Part 1: General principles |
IEC 61643-22:2015 | Low-voltage surge protective devices - Part 22: Surge protective devices connected to telecommunications and signalling networks - Selection and application principles |
IEC 61643-1:2005 | Low-voltage surge protective devices - Part 1: Surge protective devices connected to low-voltage power distribution systems - Requirements and tests |
IEC 60364-4-44:2007+AMD1:2015 CSV | Low-voltage electrical installations - Part 4-44: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances |
IEC 60099-5:2013 | Surge arresters - Part 5: Selection and application recommendations |
EN 50164-1:2008 | Lightning Protection Components (LPC) - Part 1: Requirements for connection components |
IEC 60071-2:1996 | Insulation co-ordination - Part 2: Application guide |
IEC TR 60479-4:2011 | Effects of current on human beings and livestock - Part 4: Effects of lightning strokes |
IEC 62305-4:2010 | Protection against lightning - Part 4: Electrical and electronic systems within structures |
IEC 62305-2:2010 | Protection against lightning - Part 2: Risk management |
IEC 60587:2007 | Electrical insulating materials used under severe ambient conditions - Test methods for evaluating resistance to tracking and erosion |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 62305-3:2010 | Protection against lightning - Part 3: Physical damage to structures and life hazard |
IEC 60464-2:2001+AMD1:2006 CSV | Varnishes used for electrical insulation - Part 2: Methods of test |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.