CSA Z305.6 : 1992
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
MEDICAL OXYGEN CONCENTRATOR CENTRAL SUPPLY SYSTEM FOR USE WITH NONFLAMMABLE MEDICAL GAS PIPING SYSTEMS
25-09-2009
01-01-2007
Technical Committee on Oxygen Concentrators
Preface
1 Scope
2 Reference Publications
3 Definitions and System Diagram
3.1 Definitions
3.2 Typical Supply System Diagram
4 Introduction of Oxygen 93 Per Cent
4.1 Oxygen 93 Per Cent use
4.2 Oxygen 93 Per Cent Addition Timing
5 General Requirements
5.1 Supply Requirements
5.2 Oxygen Specifications
5.3 Performance and Safety Requirements
5.4 Oxygen Flow Requirements
5.5 Distribution System
5.6 Labelling
5.7 User Detachable Connectors
5.8 Demand Accommodation
5.9 Automatic Switching
5.10 Pipeline Pressure
5.11 Inadvertant Flow
6 Materials
6.1 Oxygen Compatibility
7 Design Requirements for the Central Supply System
7.1 Components
7.2 Operating Supply
7.3 Primary Supply
7.4 Oxygen Storage Tank
7.5 Secondary Supply
7.6 Discharge point
7.7 Reserve Supply
7.8 Discharge Point
8 Air Supply
8.1 Air Intake
8.2 Compressed Air Supply
9 Control and Monitoring
9.1 Control System
9.2 Oxygen Analyzers
9.3 Role of Analyzers
9.4 Failure Safeguards
9.5 Record Keeping
9.6 Alarm Procedure
9.7 Annual Purity Test
10 Central Alarms
10.1 Requirements
10.2 Alarm Indicators for Liquid Oxygen
10.3 Electrical Supply
10.4 Separate Alarm Requirements
10.5 Alarm Indication Thresholds
11 Concentrator Performance
11.1 Requirements
12 Cylinder Filling
12.1 Requirements
12.2 Filling Operation
13 Auxiliary Supply Connection
13.1 Inlet Connection
13.2 Physical Protection
13.3 Inlet Location
13.4 Inlet Valves
13.5 Requirements
13.6 Auxiliary Supply
14 Installation
14.1 General
14.2 Pressure Component Design
14.3 Electric Systems
14.4 Cutting and Reaming Tools
14.5 Components
14.6 Documentation
15 Commissioning
15.1 Requirements
15.2 Testing
15.3 Minimum Functions and Components
16 Certification
16.1 Requirements
17 Preventive Maintenance
17.1 Requirements
Table
Appendices
A - Recommended Commissioning Checklist for Oxygen
Concentrator Systems
B - Guidelines for Preventive Maintenance of the
Central Supply System
C - Hypothetical Exercise in Sizing the Medical
Oxygen Concentrator System
Defines the minimum requirements for a medical oxygen concentrator central supply system for use as a source of supply in a nonflammable medical gas piping system which complies with CSA Standard Z305.1.
DocumentType |
Standard
|
PublisherName |
Canadian Standards Association
|
Status |
Withdrawn
|
Supersedes |
CSA Z10083 : 2008 | OXYGEN CONCENTRATOR SUPPLY SYSTEMS FOR USE WITH MEDICAL GAS PIPELINE SYSTEMS |
BS EN ISO 7396-1:2016 | Medical gas pipeline systems Pipeline systems for compressed medical gases and vacuum |
ISO 10083:2006 | Oxygen concentrator supply systems for use with medical gas pipeline systems |
EN ISO 7396-1:2016 | Medical gas pipeline systems - Part 1: Pipeline systems for compressed medical gases and vacuum (ISO 7396-1:2016) |
I.S. EN ISO 7396-1:2016 | MEDICAL GAS PIPELINE SYSTEMS - PART 1: PIPELINE SYSTEMS FOR COMPRESSED MEDICAL GASES AND VACUUM (ISO 7396-1:2016) |
CSA Z318.6 : 0 | COMMISSIONING OF MEDICAL GAS SYSTEMS IN HEALTH CARE FACILITIES |
13/30255929 DC : 0 | BS EN ISO 7396-1 - MEDICAL GAS PIPELINE SYSTEMS - PART 1: PIPELINE SYSTEMS FOR COMPRESSED MEDICAL GASES AND VACUUM |
CSA Z305.1 : 0 | NONFLAMMABLE MEDICAL GAS PIPING SYSTEMS |
DIN EN ISO 7396-1:2016-09 | MEDICAL GAS PIPELINE SYSTEMS - PART 1: PIPELINE SYSTEMS FOR COMPRESSED MEDICAL GASES AND VACUUM (ISO 7396-1:2016) |
UNE-EN ISO 7396-1:2016 | Medical gas pipeline systems - Part 1: Pipeline systems for compressed medical gases and vacuum (ISO 7396-1:2016) |
ISO 7396-1:2016 | Medical gas pipeline systems — Part 1: Pipeline systems for compressed medical gases and vacuum |
04/30088537 DC : DRAFT SEP 2004 | PREN ISO 7396-1 - MEDICAL GAS PIPELINE SYSTEMS - PART 1: PIPELINES FOR COMPRESSED MEDICAL GASES AND VACUUM |
DIN ISO 10083:2008-12 | OXYGEN CONCENTRATOR SUPPLY SYSTEMS FOR USE WITH MEDICAL GAS PIPELINE SYSTEMS |
CSA Z10083 : 2008 : R2013 | OXYGEN CONCENTRATOR SUPPLY SYSTEMS FOR USE WITH MEDICAL GAS PIPELINE SYSTEMS |
04/30084855 DC : 0 | PREN ISO 10083 - OXYGEN CONCENTRATOR SUPPLY SYSTEMS FOR USE WITH MEDICAL GAS PIPELINE SYSTEMS |
CSA Z305.2 : 0 | LOW-PRESSURE CONNECTING ASSEMBLIES FOR MEDICAL GAS SYSTEM |
CSA Z305.3 : 0 | PRESSURE REGULATORS, GAUGES AND FLOW-METERING DEVICES FOR MEDICAL GASES |
CSA Z32.4 : M86 | ESSENTIAL ELECTRICAL SYSTEMS FOR HOSPITALS |
CSA B51 : 2014 | BOILER, PRESSURE VESSEL, AND PRESSURE PIPING CODE |
CSA Z168.6 : M89 | OXYGEN ANALYZERS |
CSA Z305.4 : 0 | QUALIFICATION REQUIREMENTS FOR AGENCIES TESTING NONFLAMMABLE MEDICAL GAS PIPING SYSTEMS |
CSA Z32.2 : M89 | ELECTRICAL SAFETY IN PATIENT CARE AREAS |
CSA Z305.5 : 85(R1997) | MEDICAL GAS TERMINAL UNITS |
CGA G 4.1 : 2009 | CLEANING EQUIPMENT FOR OXYGEN SERVICE |
CSA Z305.1 : 0 | NONFLAMMABLE MEDICAL GAS PIPING SYSTEMS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.