• Shopping Cart
    There are no items in your cart

DD CEN ISO/TS 17665-2:2009

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

View Superseded by

Sterilization of health care products. Moist heat Guidance on the application of ISO 17665-1

Available format(s)

Hardcopy , PDF

Withdrawn date

01-05-2024

Superseded by

BS EN ISO 17665:2024

Language(s)

English

Published date

28-02-2009

€303.84
Excluding VAT

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Quality management system elements
5 Sterilizing agent characterization
   5.1 Sterilizing agent
   5.2 Microbicidal effectiveness
   5.3 Material effects
   5.4 Environmental considerations
6 Process and equipment characterization
   6.1 Process
   6.2 Equipment
7 Product definition
8 Process definition
9 Validation
   9.1 General
   9.2 Installation qualification (IQ)
   9.3 Operational qualification (OQ)
   9.4 Performance qualification (PQ)
   9.5 Review and approval of the validation
10 Routine monitoring and control
11 Product release from sterilization
12 Maintaining process effectiveness
   12.1 Demonstration of continued effectiveness
   12.2 Recalibration
   12.3 Maintenance of equipment
   12.4 Requalification
   12.5 Assessment of change
Annex A (informative) - Evaluation of a sterilization process
        primarily based on the measurement of physical
        parameters
Annex B (informative) - Evaluation of a sterilization process
        primarily based on biological inactivation and an
        accompanying mechanical air removal procedure
Annex C (informative) - Temperature and pressure of saturated
        steam for use in moist heat sterilization
Annex D (informative) - Special considerations for health care
        settings
Annex E (informative) - Index of normative clauses/subclauses
        of ISO 17665-1 and cited references or related
        guidance given in ISO 17665-1 and ISO/TS 17665-2
Bibliography

Gives general guidance on the development, validation and routine control of moist heat sterilization processes and is intended to explain the requirements set forth in ISO 17665-1.

Committee
CH/198
DocumentType
Standard
Pages
56
PublisherName
British Standards Institution
Status
Withdrawn
SupersededBy

This Technical Specification provides general guidance on the development, validation and routine control of moist heat sterilization processes and is intended to explain the requirements set forth in ISO17665-1. The guidance given in this Technical Specification is provided to promote good practice related to moist heat sterilization processes and to assist those developing and validating a moist heat sterilization process according to ISO17665-1.

NOTE1 The structure of the main body of this ISO Technical Specification (Clauses1 to 12) corresponds to the structure of ISO17665-1, so that the guidance given under a particular clause or subclause of this part of ISO17665 applies to the requirements given in the corresponding clause or subclause of ISO17665-1. For example, guidance for subclause5.2 of ISO17665-1:2006 is given in 5.2. This guidance is provided in addition to the guidance given in ISO17665-1:2006, AnnexA. See also AnnexeE.

NOTE2 Special considerations specific to sterilization processes performed in health care facilities are given in AnnexD.

Standards Relationship
CEN ISO/TS 17665-2:2009 Identical
ISO/TS 17665-2:2009 Identical

IEC 61010-2-040:2015 Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-040: Particular requirements for sterilizers and washer-disinfectors used to treat medical materials
ISO 15883-1:2006 Washer-disinfectors Part 1: General requirements, terms and definitions and tests
ISO 11607-2:2006 Packaging for terminally sterilized medical devices Part 2: Validation requirements for forming, sealing and assembly processes
ISO 11138-3:2017 Sterilization of health care products — Biological indicators — Part 3: Biological indicators for moist heat sterilization processes
ISO 15882:2008 Sterilization of health care products — Chemical indicators — Guidance for selection, use and interpretation of results
EN 285:2015 Sterilization - Steam sterilizers - Large sterilizers
ISO 11737-2:2009 Sterilization of medical devices Microbiological methods Part 2: Tests of sterility performed in the definition, validation and maintenance of a sterilization process
ISO 11737-1:2006 Sterilization of medical devices Microbiological methods Part 1: Determination of a population of microorganisms on products
EN 868-5:2009 Packaging for terminally sterilized medical devices - Part 5: Sealable pouches and reels of porous materials and plastic film construction - Requirements and test methods
BS EN 12442-3:2000 Animal tissues and their derivatives utilized in the manufacture of medical devices Validation of the elimination and/or inactivation of viruses and transmissible agents
EN 868-4:2017 Packaging for terminally sterilized medical devices - Part 4: Paper bags - Requirements and test methods
BS EN 12442-2:2000 Animal tissues and their derivatives utilized in the manufacture of medical devices Controls on sourcing, collection and handling
ISO 13485:2016 Medical devices Quality management systems Requirements for regulatory purposes
ISO 14937:2009 Sterilization of health care products General requirements for characterization of a sterilizing agent and the development, validation and routine control of a sterilization process for medical devices
EN 867-5:2001 Non-biological systems for use in sterilizers - Part 5: Specification for indicator systems and process challenge devices for use in performance testing for small sterilizers Type B and Type S
ISO/TR 14969:2004 Medical devices Quality management systems Guidance on the application of ISO 13485: 2003
ISO 11140-3:2007 Sterilization of health care products — Chemical indicators — Part 3: Class 2 indicator systems for use in the Bowie and Dick-type steam penetration test
EN 868-2:2017 Packaging for terminally sterilized medical devices - Part 2: Sterilization wrap - Requirements and test methods
EN 868-3:2017 Packaging for terminally sterilized medical devices - Part 3: Paper for use in the manufacture of paper bags (specified in EN 868-4) and in the manufacture of pouches and reels (specified in EN 868-5) - Requirements and test methods
ISO 11140-1:2014 Sterilization of health care products Chemical indicators Part 1: General requirements
ISO/TS 15883-5:2005 Washer-disinfectors Part 5: Test soils and methods for demonstrating cleaning efficacy
ISO 3746:2010 Acoustics Determination of sound power levels and sound energy levels of noise sources using sound pressure Survey method using an enveloping measurement surface over a reflecting plane
ISO 11140-4:2007 Sterilization of health care products — Chemical indicators — Part 4: Class 2 indicators as an alternative to the Bowie and Dick-type test for detection of steam penetration
ISO/TS 11139:2006 Sterilization of health care products Vocabulary
ISO 15883-4:2008 Washer-disinfectors Part 4: Requirements and tests for washer-disinfectors employing chemical disinfection for thermolabile endoscopes
ISO 10993-17:2002 Biological evaluation of medical devices — Part 17: Establishment of allowable limits for leachable substances
ISO 14001:2015 Environmental management systems — Requirements with guidance for use
ISO 10993-1:2009 Biological evaluation of medical devices Part 1: Evaluation and testing within a risk management process
ISO 14644-1:2015 Cleanrooms and associated controlled environments Part 1: Classification of air cleanliness by particle concentration
ISO 11140-5:2007 Sterilization of health care products — Chemical indicators — Part 5: Class 2 indicators for Bowie and Dick-type air removal tests
BS EN 12442-1:2000 Animal tissues and their derivatives utilized in the manufacture of medical devices Analysis and management of risk
ISO 11138-1:2017 Sterilization of health care products — Biological indicators — Part 1: General requirements
ANSI/AAMI ST79:2017 COMPREHENSIVE GUIDE TO STEAM STERILIZATION AND STERILITY ASSURANCE IN HEALTH CARE FACILITIES
ISO 14971:2007 Medical devices Application of risk management to medical devices
ISO 11607-1:2006 Packaging for terminally sterilized medical devices Part 1: Requirements for materials, sterile barrier systems and packaging systems
ISO 14161:2009 Sterilization of health care products Biological indicators Guidance for the selection, use and interpretation of results
ISO 14040:2006 Environmental management Life cycle assessment Principles and framework
ISO 15883-2:2006 Washer-disinfectors — Part 2: Requirements and tests for washer-disinfectors employing thermal disinfection for surgical instruments, anaesthetic equipment, bowls, dishes, receivers, utensils, glassware, etc.
ISO 17664:2017 Processing of health care products Information to be provided by the medical device manufacturer for the processing of medical devices
EN 13060:2014 Small steam sterilizers
ISO 17665-1:2006 Sterilization of health care products — Moist heat — Part 1: Requirements for the development, validation and routine control of a sterilization process for medical devices

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.