DD IEC/TS 62558:2011

Current

Current

The latest, up-to-date edition.

Ultrasonics. Real-time pulse-echo scanners. Phantom with cylindrical, artificial cysts in tissue-mimicking material and method for evaluation and periodic testing of 3D-distributions of void-detectability ratio (VDR)

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

30-06-2011

€322.53
Excluding VAT

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols
5 Ambient conditions of measurement with the phantom
6 Specification of TMM 3D artificial anechoic-cyst
  phantom
7 Principle of measurement using the 3D anechoic void
  phantom
Annex A (informative) - Description of construction of
        an example phantom and test results
Annex B (informative) - System description
Annex C (informative) - Rationale
Annex D (informative) - Uniformity measurement
Bibliography

Gives essential characteristics of a phantom and method for the measurement of void-detectability ratio for medical ultrasound systems and related transducers.

Committee
EPL/87
DevelopmentNote
Supersedes 08/30177593 DC. (07/2011)
DocumentType
Standard
Pages
54
PublisherName
British Standards Institution
Status
Current
Supersedes

IEC/TS 62558:2011(E) specifies essential characteristics of a phantom and method for the measurement of void-detectability ratio for medical ultrasound systems and related transducers. It is restricted to the aspect of long-term reproducibility of testing results. Medical diagnostic ultrasound systems and related transducers need periodic testing as the quality of medical decisions based on ultrasonic images may decrease over time due to progressive degradation of essential systems characteristics. The TMM (Tissue Mimicking Material) phantom is intended to be used to measure and to enable documentation of changes in void-detectability ratio in periodic tests over years of use. This technical specification establishes:
- Important characteristics and requirements for a TMM 3D artificial cyst phantom using anechoic voids
- A design example of a 3D artificial cyst phantom, the necessary test equipment and use of relevant computer software algorithms.
This technical specification is currently applicable for linear array transducers. A uniformity test prior to void-detectability ratio (VDR) measurement is recommended.

Standards Relationship
IEC TS 62558:2011 Identical

IEC 60050-802:2011 International Electrotechnical Vocabulary (IEV) - Part 802: Ultrasonics
IEC 62453-1:2016 Field device tool (FDT) interface specification - Part 1: Overview and guidance
IEC 61391-1:2006+AMD1:2017 CSV Ultrasonics - Pulse-echo scanners - Part 1: Techniques for calibrating spatial measurement systems and measurement of point-spread function response
IEC 61391-2:2010 Ultrasonics - Pulse-echo scanners - Part 2: Measurement of maximum depth of penetration and local dynamic range
IEC 60761-1:2002 Equipment for continuous monitoring of radioactivity in gaseous effluents - Part 1: General requirements
IEC 62270:2013 Guide for computer-based control for hydroelectric power plant automation