DEFSTAN 00-101(PT1)/1(2005) : 2005
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
DESIGN STANDARDS FOR EXPLOSIVES SAFETY IN MOD SHIPS AND SUBMARINES - PART 1: SURFACE SHIPS
Hardcopy , PDF
27-06-2008
English
01-01-2005
Foreword
Introduction
1 SCOPE
2 WARNING
3 RELATED DOCUMENTS
4 DEFINITIONS AND ABBREVIATIONS
5 AMENDMENT
6 SPONSORSHIP OF THE REQUIREMENT AND SECURITY
7 INTRODUCTION TO THE PROCESS FOR APPROVAL OF A CERTIFICATE
OF SAFETY EXPLOSIVES
7.1 Introduction to the Process
7.4 The JSP 430 process (2nd stage)
7.5 The Generic Naval Environment
7.6 Magazine and Munition Protection Strategy
7.7 Warships In Harbour
7.8 Regulatory Documentation
SECTION 1 - PERFORMANCE REQUIREMENTS, ACOP AND GUIDANCE
8 PRINCIPLES FOR THE SAFE STOWAGE, PROTECTION AND HANDLING
OF EXPLOSIVE MUNITIONS/STORES IN MOD SHIPS
8.1 Description
8.2 Performance Requirements - Basic Principles for the
Safety, Protection and Handling of Magazines and
Munitions in MoD Ships
8.3 ACOP for Relationship of Explosive Safety to
Vulnerability Reduction
8.4 ACOP for Basic Principles of Capacity and Size
8.5 ACOP for Basic Principles for the Safety and
Protection of Magazines and Munitions
8.6 ACOP for Ready Use Magazines
8.7 ACOP for Small Quantity Top Up (SQTU) Magazines
8.8 Guidance - Threat Hazard Assessment and developing
Magazine and Munition Protection Strategies
8.9 Guidance - Basic Principles for Environmental Hazards
8.10 Guidance - Explosives Compatibility Groups
8.11 Guidance - Bulk Explosives
8.12 Guidance - RATTAM Protection Assessment
8.13 Guidance - BR 862 and other Safety and Environmental
Management Systems (SEMS)
9 DESIGNATED DANGER AREAS (DDA)
9.1 Description
9.2 Performance Requirements for DDAs
9.3 ACOP for DDAs (General)
9.4 ACOP for Electrical and Fire Fighting Requirements
in DDAs
9.5 ACOP for Package Examination Room (PER)
9.6 ACOP for Marking of Areas around Launchers
9.7 Guidance - DDAs (General)
9.8 Guidance - DDAs (Electrical Installations and
Fire Fighting Arrangements)
9.9 Guidance - Package Examination Rooms (PERs)
9.10 Guidance - Marking of Areas around Launchers
9.11 Guidance - Separation of RAS(L) and RAS(A) Areas
10 ADJACENT COMPARTMENTS
10.1 Description
10.2 Performance Requirements for Adjacent Compartments
10.3 ACOP for Reduction of Hazards from Adjacent Compartments
10.4 ACOP for POL and Tanks Adjacent to a Magazine
10.5 ACOP for Smoke/Heat Detectors in Adjacent Compartments
10.6 Guidance - Adjacent Compartments (General)
10.7 Guidance - Adjacent Compartments (POL Products)
10.8 Guidance - Adjacent Compartments (Smoke/Heat Detectors)
11 GENERAL MAGAZINE CONSTRUCTION REQUIREMENTS
11.1 Description
11.2 Performance Requirements for General Magazine Construction
11.3 ACOP for Structural Integrity of Magazines
11.4 ACOP for Painting and Preservation in Magazines
11.5 ACOP for Automatic Air Escapes (AAE)
11.6 ACOP for Air Systems in Magazines
11.7 ACOP for Drainage/Flooding Arrangements in Magazines
11.8 ACOP for Access to Magazines
11.9 ACOP for Cupboards and Drawers
11.10 ACOP for Emergency Lighting
11.11 ACOP for Magazine Hazard Warning/Safety Signs &
Notices
11.12 ACOP for Protection from Efflux
11.13 ACOP for Pipework Systems in Magazines
11.14 Guidance - Safety Assessment for the Construction of
the Magazine/Munition Area
11.15 Guidance - Painting and Preservation
11.16 Guidance - AAEs
11.17 Guidance - Air Systems in Magazines
11.18 Guidance - Drainage for Magazines
11.19 Guidance - Access to Magazines
11.20 Guidance - Emergency Lighting for Magazines
11.21 Guidance - Safety Signs and Notices
11.22 Guidance - Protection from Rocket Motor Efflux
11.23 Guidance - Pipework Systems in Magazines (Couplings)
12 MUNITION STOWAGES AND FITTINGS
12.1 Description
12.2 Performance Requirements for Munition Stowages and
Fittings
12.3 ACOP for General Munition Stowage Requirements
12.4 ACOP for Clearance between Stowages and Adjacent Boundaries
12.5 ACOP for Identification of Stowages and Stowage
Capacity
12.6 ACOP for permitted magazine contents
12.7 Guidance - Optimised Stowage Principles to reduce
consequences from initiation events
12.8 Guidance - Safe and Secure Stowage
12.9 Guidance - Clearances between Stowages and Adjacent
Boundaries
12.10 Guidance - Identification of Stowages and Stowage
Capacity
12.11 Guidance - Permitted Magazine Contents
13 MAGAZINE LOCKERS
13.1 Description
13.3 Performance Requirements for Magazine Locker Flooding
Arrangements
13.4 Performance Requirements for Siting and Installation
of Magazine Lockers
13.5 ACOP for Magazine Locker Design
13.6 ACOP for Magazine Locker Flooding Arrangements
13.7 ACOP for Siting and Installation of Magazine Lockers
13.8 ACOP for Detonator Locker Requirements
13.9 ACOP for Depth Charge Fuze RU Magazine Lockers
13.10 ACOP for General Locker Notices and Notice Boards
13.11 ACOP for Magazine Locker Contents
13.12 Guidance - Safety of Magazine Lockers and Detonator
Lockers
13.13 Guidance - Flooding of Magazine Lockers
13.14 Guidance - Detonator Lockers
13.15 Guidance - Ready Use Magazines/Lockers
14 FIRE PREVENTION
14.1 Description
14.2 Performance Requirements for Fire Prevention
14.3 ACOP for Fire Prevention Through Design
14.4 ACOP for Fire Prevention Through the Explosives
Safety Management System
14.5 Guidance - Fire Prevention (General)
15 FIRE FIGHTING ARRANGEMENTS
15.1 Description
15.2 Performance Requirements for General Fire Fighting
Arrangements
15.3 ACOP for Common Principles of Fire Detection and
Spray Control Systems
15.4 ACOP for Fire Detection
15.5 ACOP for Magazine Spray Systems (General)
15.6 ACOP for Rapid Reaction Spray Systems (RRSS)
15.7 ACOP for RRSS - Heat Activated Systems
15.8 ACOP for RRSS - Smoke Activated Systems
15.9 ACOP for RRSS - Local and Remote Operation
Requirements
15.10 ACOP for RRSS - Manual Intervention in Operation
15.11 ACOP for Thermal Bulb activated Spray Systems
15.12 ACOP for Manual Spray Systems
15.13 ACOP for Pressurised Fresh Water Reservoirs
15.14 ACOP for Seawater Supply Systems
15.15 ACOP for Water Flow Sensors, Pressure Sensors
and Associated Alarms
15.16 ACOP for Provision of Drains in Spray System Pipework
15.17 ACOP for Magazine Spray System Signs/Notices
15.18 ACOP for First Aid Fire Fighting Equipment in Magazines
15.19 ACOP for Fire Fighting Arrangements in Silo Magazines
15.20 ACOP for Fire Fighting Arrangements in DDAs (including
Vehicle Decks and Weapon Parks)
15.21 ACOP for Fire Fighting Arrangements in Naval Armament
Lighters
15.22 Guidance - Magazine Fire Fighting Arrangements -
General
15.23 Guidance Design Requirements for Smoke and Heat
Detection
15.24 Guidance - Design Requirements for Spray Coverage
15.25 Guidance - Requirements for Fresh Water Priming
15.26 Guidance - Requirements for Free Air Space around
stowages
15.27 Guidance - Integration of Magazine Fire Alarm Systems
15.28 Guidance - Munition Fire Characteristics
15.29 Guidance - First Aid Fire Fighting Equipment for
Magazines and DDAs
16 MAGAZINE AIR CONDITIONING/VENTILATION SYSTEMS
16.1 Description
16.2 Performance Requirements for Magazine Air
Conditioning/Ventilation Systems
16.3 ACOP for Environmental Requirements
16.4 ACOP for Magazine Ventilation System Design and
Installation
16.5 ACOP for Magazine Ventilation Trunking
16.6 ACOP for Magazine Ventilation Isolation Arrangements
16.7 ACOP for Magazine Ventilation Valves - Local and
Remote Operating Positions
16.8 ACOP for Magazine Ventilation System Notices
16.9 Guidance - Magazine Air Conditioning/Ventilation
Systems
17 MITIGATION METHODS TO PREVENT INITIATION OR REDUCE
CONSEQUENCES FROM MUNITION INITIATION EVENTS
17.1 Description
17.2 Performance Requirements for Explosives Mitigation
Methods
17.3 ACOP for Mitigation measures in Surface Ships
17.4 ACOP for Mitigation for Fire
17.5 ACOP for Mitigation for Fragment Attack
17.6 ACOP for Mitigation for Bullet Attack
17.7 ACOP for Mitigation for Blast Overpressure and
Under Water Shock
17.8 ACOP for Mitigation for Sympathetic Reaction
17.9 ACOP for Mitigation for Rocket Efflux and
Propulsive Reaction
17.10 ACOP for Mitigation for Stowage of Shaped Charge
Warheads including Demolition Munitions
17.11 ACOP for Mitigation Tests or Assessments
17.12 Guidance on Fundamental Principles of Mitigating
Explosion Effects
17.13 Guidance on Deriving Protection and Mitigation Methods
17.14 Guidance - Explosives Mitigation Techniques
18 RATTAM PROTECTION
18.1 Description
18.2 Performance Requirement for RATTAM Protection
18.3 ACOP for RATTAM Requirement
18.4 ACOP for Methods of RATTAM Protection
18.5 ACOP for Angle of RATTAM Attack
18.6 ACOP for RATTAM Assessment
18.7 Guidance - RATTAM Concept
19 MAGAZINE OVER PRESSURE RELIEF - VENTING PLATES
19.1 Description
19.2 Performance Requirement
19.3 ACOP for Over Pressure Venting Plates and Vent Routes
19.4 ACOP for Marking of Over Pressure Vent Plates
19.5 Guidance - Over Pressure Vent Design Assessment
20 ANTI FLASH PROTECTION
20.1 Description
20.2 Performance Requirement
20.3 ACOP for Anti Flash Protection
20.4 ACOP for Anti Flash Protection in Weapon Lifts and
Hoists
20.5 Guidance - Anti Flash Protection
21 SECURITY AND ANTI SABOTAGE ARRANGEMENTS
21.1 Description
21.2 Performance Requirements for Security and Anti
Sabotage
21.3 ACOP for Security of Doors, Hatches, Manholes
and Escape Scuttles
21.4 ACOP for Prevention of Access
21.5 ACOP for Security and Anti Sabotage Arrangements
21.6 Guidance - Security and Anti Sabotage Arrangements
22 ANTI STATIC REQUIREMENTS AND CONDUCTING DECKS
22.1 Description
22.2 Performance Requirements for Anti Static Measures
and Conducting Decks
22.3 ACOP for Anti Static Measures and Conducting Decks
22.4 Guidance - Anti Static Measures and Conducting Decks
23 AMMUNITION HANDLING - EMBARKING, STOWING AND SUPPLY
23.1 Description
23.2 Performance Requirements for Ammunition Handling
Safety Policy
23.3 Performance Requirements for Ammunition Handling -
Novel Designs
23.4 Performance Requirements for Ammunition Routes
23.5 Performance Requirements for Explosives
Handling/Lifting Equipment
23.6 ACOP for Ammunition Handling
23.7 ACOP for Ammunition Routes
23.8 ACOP for Millers' Flaps
23.9 ACOP for Handling/Lifting Equipment in Magazines
and DDAs
23.10 ACOP for Ammunition Route Drawings
23.11 Guidance - Ammunition Handling Safety Assessment
23.12 Guidance - Mechanical Handling Equipment in MOD Ships
24 PLATFORM DYNAMIC SAFETY HAZARD ASSESSMENT
24.1 Description
24.2 Performance Requirements for Platform Dynamic Safety
24.3 ACOP for Safe Integration of OME Safety Cases into
Platform Safety Cases
24.4 ACOP for Weapon Installation Safe Firing Arcs
24.5 Guidance for Safe Integration of OME Safety Cases
into Platform Safety Cases
24.6 Guidance on Weapon Installation Safe Firing Arcs
24.7 Guidance - Platform Dynamic Safety for Combat Systems
24.8 Guidance on Platform Dynamic Safety for Missile Systems
24.9 Guidance on Platform Dynamic Safety for Torpedo Systems
SECTION 2 - REGULATIONS
25 GENERAL APPLICATION OF LEGISLATION
26 MOD DISAPPLICATION
27 MOD REGULATION
ANNEX A - RELATED DOCUMENTS
ANNEX B - ABBREVIATIONS
ANNEX C - DEFINITIONS
ANNEX D - THREAT HAZARD ASSESSMENT
ANNEX E - SAMPLE S285K
ANNEX F - TYPICAL MAGAZINE CONTENTS BOARD
ANNEX G - GUIDANCE FOR FLASHTIGHT BARRIERS
ANNEX H - TYPICAL SHIP AMMUNITION ROUTE PROFILE
Applies to the design, construction and ship fitting of all MOD Ships built to MOD or Classification Society constructional standards and operated by the Royal Navy, Army (including Special Forces), Royal Air Force, RFA or MS.
DevelopmentNote |
Supersedes DEFSTAN 08-101(PT1)/1(2000) and NES 183 PT1 (04/2005)
|
DocumentType |
Standard
|
Pages |
158
|
PublisherName |
UK Ministry of Defence Standards
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
DEFSTAN 02-603/2(2001) : INTERIM | REQUIREMENTS FOR THE POLICY, DESIGN AND INSTALLATION OF FIRE DETECTION SYSTEMS IN SHIPS |
IEC 60079-10:2002 | Electrical apparatus for explosive gas atmospheres - Part 10: Classification of hazardous areas |
AOP 39 : 2010 | GUIDANCE ON THE ASSESSMENT AND DEVELOPMENT OF INSENSITIVE MUNITIONS (IM) |
DEFSTAN 07-251/1(2000) : 2000 | REQUIREMENTS FOR THE PRESERVATION AND PAINTING OF COMPARTMENTS IN SURFACE SHIPS - CATEGORY 2 |
DEFSTAN 08-123/1(2000) : 2000 | REQUIREMENTS FOR THE DESIGN AND TESTING OF EQUIPMENTS TO MEET ENVIRONMENTAL CONDITIONS - CATEGORY 2 |
DEFSTAN 02-764/1(2000) : 2000 | FLAME METAL SPRAYING AND HOT DIP GALVANIZING OF SHIPS STRUCTURE AND FITTINGS |
DEFSTAN 08-100/1(2000) : 2000 | GRP SHIPS STRUCTURAL DESIGN - CATEGORY 2 |
DEFSTAN 08-146/1(2001) : 2001 | REQUIREMENTS FOR LOCKERS (MAGAZINE, READY-USE MAGAZINE AND DETONATORS) USED FOR THE STOWAGE OF EXPLOSIVE STORES IN HM SURFACE SHIPS AND HM SUBMARINES |
STANAG 4382 : 2003 | SLOW HEATING, MUNITIONS TEST PROCEDURES |
DEFSTAN 08-120/1(2000) : 2000 | REQUIREMENTS FOR DETERMINING THE SHOCK STRENGTH OF EQUIPMENT - CATEGORY 2 |
STANAG 4241 : 2003 | BULLET IMPACT, MUNITION TEST PROCEDURES |
DEFSTAN 02-361/1(2000) : 2000 | VALVE ROAD GEARING (LTD CIRC) CATEGORY 3 |
MIL-STD-2105 Revision D:2011 | HAZARD ASSESSMENT TESTS FOR NON-NUCLEAR MUNITIONS |
BS 5378:1976 | Specification for safety colours and safety signs |
DEFSTAN 02-127/1(2000) : 2000 | ACCESS FITTINGS AND EQUIPMENT |
DEFSTAN 02-784/2(2002) : 2002 | REQUIREMENTS FOR SAFETY SIGNS AND COLOURS |
DEFSTAN 08-107/2(2001) : 2001 | GENERAL REQUIREMENTS FOR THE DESIGN OF ELECTROMECHANICAL AND NAVAL WEAPON EQUIPMENT - CATEGORY 2 |
DEFSTAN 00-56(PT2)/3(2004) : INTERIM | SAFETY MANAGEMENT REQUIREMENTS FOR DEFENCE SYSTEMS - PART 2: GUIDANCE ON ESTABLISHING A MEANS OF COMPLYING WITH PART 1 |
DEFSTAN 02-188/1(2000) : 2000 | REQUIREMENTS FOR THE PROCUREMENT, STORAGE AND USE OF TIMBER |
DEFSTAN 07-228/1(2000) : 2000 | REQUIREMENTS AND SAFETY REGULATIONS FOR ELECTRICAL EQUIPMENT AND INSTALLATIONS FITTED IN MAGAZINES, SUBMARINE WEAPON STORAGE COMPARTMENTS, ADJACENT COMPARTMENTS AND DESIGNATED AREAS - CATEGORY 1 |
DEFSTAN 02-703/1(2000) : 2000 | THERMAL AND ACOUSTIC INSULATION OF HULL AND MACHINERY |
DEFSTAN 07-279/2(2003) : 2003 | REQUIREMENTS FOR REPLENISHMENT AT SEA HM SURFACE SHIPS - CATEGORY 2 |
STANAG 4240 : 2003 | LIQUID FUEL/EXTERNAL FIRE, MUNITION TEST PROCEDURES |
DEFSTAN 02-141/1(2000) : 2000 | REQUIREMENTS AND ORGANIZATION FOR THE MANAGEMENT ACCESS TO AND WITHIN COMPARTMENTS (SURFACE SHIPS) CATEGORY N/A |
DEFSTAN 08-147(PT2)/1(2000) : 2000 | REQUIREMENTS FOR DAMAGE CONTROL AND FIRE PROTECTION FOR THE SAFETY OF SURFACE SHIPS AND SUBMARINES - CATEGORY 1 - PART 2: SUBMARINES |
DEFSTAN 02-712/1(2000) : 2000 | REQUIREMENTS FOR SEWAGE AND GREY - WATER SYSTEMS FOR SURFACE SHIPS (OBSOLESCENT) CATEGORY 2 |
DEFSTAN 08-46/2(2002) : 2002 AMD 2 2004 | THE ELECTRIC, MAGNETIC AND ELECTROMAGNETIC ENVIRONMENT |
DEFSTAN 00-56(PT1)/3(2004) : INTERIM | SAFETY MANAGEMENT REQUIREMENTS FOR DEFENCE SYSTEMS - PART 1: REQUIREMENTS |
STANAG 4439 : 2010 | POLICY FOR INTRODUCTION AND ASSESSMENT OF INSENSITIVE MUNITIONS (IM) |
DEFSTAN 08-104/1(2000) : 2000 | COMPRESSED AIR SYSTEMS - CATEGORY 2 |
STANAG 4496 : 2006 | FRAGMENT IMPACT, MUNITIONS TEST PROCEDURE |
DEFSTAN 02-748/2(2002) : 2002 | REQUIREMENTS FOR STRAINERS IN HM SURFACE SHIPS AND SUBMARINES |
DEFSTAN 02-360/2(2001) : 2001 | GUIDANCE TO THE SELECTION OF LOW PRESSURE METRIC STANDARD VALVES |
DEFSTAN 00-35/2(1996) : 1996 AMD 1 1997 | ENVIRONMENTAL HANDBOOK FOR DEFENCE MATERIEL |
DEFSTAN 02-502/1(2000) : 2000 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS CATEGORY 2 |
DEFSTAN 07-207/1(2000) : 2000 | REQUIREMENTS FOR PADLOCKS - CATEGORY 3 |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.